CoChat

Non-invasive cardiac imaging evaluation of patients with chronic systolic heart failure: a report from the European Association of Cardiovascular Imaging (EACVI)

Open access
Gimelli, A., Lancellotti, P., Badano, L. P., Lombardi, M., Gerber, B., Plein, S., Neglia, D., Edvardsen, T., Kitsiou, A., Scholte, A. J. H. A., Schroder, S., Cosyns, B., Gargiulo, P., Zamorano, J. L., Perrone-Filardi, P. · 2014 · European Heart Journal
Cited by 40

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In patients with heart failure (HF) and reduced ejection fraction (EF), non-invasive cardiac imaging provides diagnostic, prognostic, and therapeutic information and assists decision-making. The aim of this consensus paper is to provide an overview of the clinical applications of non-invasive cardiac imaging in the management of HF patients with systolic dysfunction, mostly focusing on impact on clinical decision-making (Figure 1). Use of cardiac imaging for the management of patients with chronic systolic heart failure. HF, heart failure; BNP, brain natriuretic peptide; CMR, cardiac magnetic resonance; EF, ejection fraction; CAD, coronary artery disease; CCTA, cardiac computed tomographic angiography; SPECT, single photon emission computed tomography; PET, positron emission tomography; ICD, implantable cardioverter defibrillator; CRT, cardiac resynchronization therapy; OMT, optimal medical therapy. *might precede stress imaging in patients with angina. In patients with suspected HF, an electrocardiogram, chest X-ray, and brain natriuretic peptide (BNP or NT-proBNP) assay should be performed before non-invasive cardiac imaging,1 but in particular clinical situations with high likelihood of the disease, i.e. symptoms of HF in patients with previous myocardial infarction, cardiac imaging might be directly performed without previous BNP assay. Left ventricular (LV) systolic dysfunction, conventionally identified when EF at rest is <50%, is detected in ∼50% of patients with HF. However, EF does not accurately reflect the contractile status of the myocardium as it is influenced by loading conditions. In addition, EF does not reflect cardiac output that can be preserved in patients with low EF but large left ventricle, or decreased in patients with normal EF but reduced LV chamber size or impaired diastolic function or severe mitral regurgitation. Additional parameters that are usually abnormal in patients with systolic HF include increased end-diastolic diameter and volume (LV diameter >60 mm or 32 mm/m2 with LV volume >97 mL/m2) and end-systolic diameter and volume (LV diameter >45 mm or 25 mm/m2 with LV volume >43 mL/m2). To measure these parameters and establish the diagnosis of systolic HF either an echocardiogram or cardiac magnetic resonance (CMR) at rest should be performed.1 Using echocardiography, EF should be calculated adopting the apical biplane rule (modified Simpson rule), with the use of contrast agent when <80% of the endocardial border is visualized, whereas visual assessment of EF is not recommended.2 However, clinicians should be aware of the suboptimal reproducibility of echocardiographic EF measurement3 and rely on examinations performed by experienced operators. Although still not widely diffused, three-dimensional echocardiography improves reproducibility of EF measurement.2 Left ventricular systolic function can also be assessed measuring atrioventricular plane systolic excursion, systolic tissue Doppler velocities, and deformation indexes, including strain and strain rate. Although abnormalities of these indexes precede EF decrease, and might be more sensitive to identify pre-clinical HF,4 their use in clinical practice is still limited due to reduced reproducibility and lack of standardization. Echocardiography allows accurate evaluation of LV diastolic function that is commonly impaired in patients with reduced EF. Guidelines recommend a comprehensive evaluation of echocardiographic and Doppler parameters, to assess LV mass, left atrial dilation, and functional diastolic indexes. These latter should include tissue Doppler imaging-derived early diastolic myocardial velocities (e′) (normal >8 cm/s septal, >10 cm/s lateral, or >9 cm/s average) that reflects myocardial relaxation and the E/e′ ratio (normal <15) that reflects filling pressure. The mitral inflow E/A ratio (normal 1–2) identifies the pattern of diastolic dysfunction (restrictive if >2, impaired relaxation if <1 or ‘pseudonormal’ if between 1 and 2 but decreasing >0.5 during the Valsalva maneuver) providing insights into the loading conditions of the left ventricle that can assist therapeutic management. Cardiac magnetic resonance is the most valuable alternative to echocardiography and represents first-line technique in patients with unfavourable acoustic window, like those with pulmonary diseases, or in patients with complex congenital diseases, or in patients in whom characterization of myocardial tissue is needed (see below). At variance with echocardiography, measurements are independent on geometric assumptions, making CMR the gold standard technique for the assessment of EF and LV volumes5 (Figure 2). In addition, the right ventricle can be accurately evaluated and, by combining cine and flow-sensitive CMR imaging, valvular regurgitation and intracardiac shunt volumes can be quantified.5 Head-to-head comparison of left ventricular function assessment with 64-row computed tomography (64-row CT), biplane left cineventricu

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehu433

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 40

Metadata

Authors
Gimelli, A., Lancellotti, P., Badano, L. P., Lombardi, M., Gerber, B., Plein, S., Neglia, D., Edvardsen, T., Kitsiou, A., Scholte, A. J. H. A., Schroder, S., Cosyns, B., Gargiulo, P., Zamorano, J. L., & Perrone-Filardi, P.
Venue
European Heart Journal
Published
2014-11-21
Volume
35
Issue
48
Pages
3417-3425
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W1981869075
Cited by
40
References
3
FWCI
2.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.