Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A study of implanted cardiac rhythm recorders in advanced cardiac AL amyloidosis

Sayed, R. H., Rogers, D., Khan, F., Wechalekar, A. D., Lachmann, H. J., Fontana, M., Mahmood, S., Sachchithanantham, S., Patel, K., Hawkins, P. N., Whelan, C. J., Gillmore, J. D.·2015·European Heart Journal

Abstract

AIMS: AL amyloidosis may respond to chemotherapy but two-thirds of patients with severe cardiac involvement die within a year of diagnosis, purportedly from tachyarrhythmias or electromechanical dissociation. We sought to characterize the nature of cardiac arrhythmias in severe cardiac AL amyloidosis using implanted cardiac rhythm recorders. METHODS AND RESULTS: Implantable loop recorders (ILRs) were inserted within 24 h of baseline evaluation at the UK National Amyloidosis Centre, into 20 consecutive patients with newly diagnosed severe cardiac AL amyloidosis and symptoms of syncope or pre-syncope. Weekly ILR recordings and additional recordings at the time of symptoms were obtained. Median (range) follow-up from baseline was 308 (10-399) days. Thirteen patients died, and median survival in the whole cohort was 61 days from device insertion. In each of eight evaluable cases, death was heralded by bradycardia, usually associated with complete atrioventricular block (CAVB), followed shortly thereafter by pulseless electrical activity. Four patients received pacemakers, a median (range) of 7 (3-38) h after development of symptomatic CAVB, but these did not prevent rapid cardiac decompensation and death in three cases. Despite 272 loop recordings, there was only one episode of non-sustained ventricular tachycardia, which was preceded by severe bradycardia. Patients who died had significantly worse global left ventricular strain on echocardiography (P = 0.029) and reduced 6 min walk distance (P = 0.048) at baseline compared with survivors. CONCLUSIONS: The discovery that bradyarrhythmias heralded terminal cardiac decompensation in most patients with severe cardiac AL amyloidosis supports a study of prophylactic pacemaker insertion in this patient population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehu506

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 165

Metadata

Authors
Sayed, R. H., Rogers, D., Khan, F., Wechalekar, A. D., Lachmann, H. J., Fontana, M., Mahmood, S., Sachchithanantham, S., Patel, K., Hawkins, P. N., Whelan, C. J., & Gillmore, J. D.
Venue
European Heart Journal
Published
2014-12-29
Volume
36
Issue
18
Pages
1098-1105
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2148613212
Cited by
165
References
2
FWCI
3.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A study of implanted cardiac rhythm recorders in advanced cardiac AL amyloidosis. https://app.cochat.ai/papers/10.1093/eurheartj/ehu506
The paper
Sayed, R. H., Rogers, D., Khan, F., Wechalekar, A. D., Lachmann, H. J., Fontana, M., Mahmood, S., Sachchithanantham, S., Patel, K., Hawkins, P. N., Whelan, C. J., & Gillmore, J. D. (2015). A study of implanted cardiac rhythm recorders in advanced cardiac AL amyloidosis. European Heart Journal. https://doi.org/10.1093/eurheartj/ehu506

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.