A prospective randomized evaluation of the TriGuard™ HDH embolic DEFLECTion device during transcatheter aortic valve implantation: results from the DEFLECT III trial
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
AIMS: To evaluate the safety, efficacy, and performance of the TriGuard™ HDH Embolic Deflection Device (TriGuard) compared with no cerebral protection in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: From February 2014 to March 2015, 85 subjects undergoing TAVI at 13 centres in Europe and Israel were randomized to TriGuard protection vs. no protection. Subjects underwent neurologic and cognitive evaluation at baseline, pre-discharge and 30 days; cerebral diffusion-weighted magnetic resonance imaging was performed at 4 ± 2 days post-procedure and at 30 days. Technical success, which included complete 3-vessel cerebral coverage, was achieved in 88.9% (40/45) of cases. The primary in-hospital procedural safety endpoint (death, stroke, life-threatening or disabling bleeding, stage 2 or 3 acute kidney injury, or major vascular complications) occurred in 21.7% of TriGuard and 30.8% of control subjects (P = 0.34). In the Per Treatment population (subjects with complete three-vessel cerebral coverage), TriGuard use was associated with greater freedom from new ischaemic brain lesions (26.9 vs. 11.5%), fewer new neurologic deficits detected by the National Institutes of Health Stroke Scale (3.1 vs. 15.4%), improved Montreal Cognitive Assessment (MoCA) scores, better performance on a delayed memory task (P = 0.028) at discharge, and a >2-fold increase in recovery of normal cognitive function (MoCA score >26) at 30 days. CONCLUSION: TriGuard cerebral protection during TAVI is safe and complete cerebral vessel coverage was achieved in 89% of subjects. In this exploratory study, subjects undergoing protected TAVI had more freedom from ischaemic brain lesions, fewer neurologic deficits, and improved cognitive function in some domains at discharge and 30 days compared with controls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Montreal Cognitive Assessment, MoCA: a brief screening tool for mild cognitive impairment
Nasreddine, Z. S., Phillips, N. A., Bédirian, V., Charbonneau, S., Whitehead, V., Collin, I., Cummings, J. L., & Chertkow, H. (2005) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.53221.x · Cited by 25,553
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
Authors/Task Force Members, Vahanian, A., Baumgartner, H., Bax, J., Butchart, E., Dion, R., Filippatos, G., Flachskampf, F., Hall, R., Iung, B., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl428 · Cited by 3,593
Sacco, R. L., Kasner, S. E., Broderick, J. P., Caplan, L. R., Connors, J. J. (., Culebras, A., Elkind, M. S. V., George, M. G., Hamdan, A. D., Higashida, R. T., et al. (2013) · Stroke · doi:10.1161/str.0b013e318296aeca · Cited by 3,569
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs253 · Cited by 2,899
Cited by
Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., Blackstone, E. H., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.02.038 · Cited by 1,313
VARC-3 WRITING COMMITTEE, Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa799 · Cited by 915
Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement
Kapadia, S. R., Kodali, S., Makkar, R., Mehran, R., Lazar, R. M., Zivadinov, R., Dwyer, M. G., Jilaihawi, H., Virmani, R., Anwaruddin, S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.023 · Cited by 509
Haussig, S., Mangner, N., Dwyer, M. G., Lehmkuhl, L., Lücke, C., Woitek, F., Holzhey, D. M., Mohr, F. W., Gutberlet, M., Zivadinov, R., et al. (2016) · JAMA · doi:10.1001/jama.2016.10302 · Cited by 367
Proposed Standardized Neurological Endpoints for Cardiovascular Clinical Trials
Lansky, A. J., Messé, S. R., Brickman, A. M., Dwyer, M., van der Worp, H. B., Lazar, R. M., Pietras, C. G., Abrams, K. J., McFadden, E., Petersen, N. H., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.045 · Cited by 160
Self-citation
Metadata
- Authors
- Lansky, A. J., Schofer, J., Tchetche, D., Stella, P., Pietras, C. G., Parise, H., Abrams, K., Forrest, J. K., Cleman, M., Reinöhl, J., Cuisset, T., Blackman, D., Bolotin, G., Spitzer, S., Kappert, U., Gilard, M., Modine, T., Hildick-Smith, D., Haude, M., Margolis, P., Brickman, A. M., Voros, S., & Baumbach, A.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-05-19
- Volume
- 36
- Issue
- 31
- Pages
- 2070-2078
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W1956430362
- Cited by
- 308
- References
- 28
- FWCI
- 31.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.