ALternate Site Cardiac ResYNChronization (ALSYNC): a prospective and multicentre study of left ventricular endocardial pacing for cardiac resynchronization therapy
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
AIMS: The ALternate Site Cardiac ResYNChronization (ALSYNC) study evaluated the feasibility and safety of left ventricular endocardial pacing (LVEP) using a market-released pacing lead implanted via a single pectoral access by a novel atrial transseptal lead delivery system. METHODS AND RESULTS: ALSYNC was a prospective clinical investigation with a minimum of 12-month follow-up in 18 centres of cardiac resynchronization therapy (CRT)-indicated patients, who had failed or were unsuitable for conventional CRT. The ALSYNC system comprises the investigational lead delivery system and LVEP lead. Patients required warfarin therapy post-implant. The primary study objective was safety at 6-month follow-up, which was defined as freedom from complications related to the lead delivery system, implant procedure, or the lead ≥70%. The ALSYNC study enrolled 138 patients. The LVEP lead implant success rate was 89.4%. Freedom from complications meeting the definition of primary endpoint was 82.2% at 6 months (95% CI 75.6-88.8%). In the study, 14 transient ischaemic attacks (9 patients, 6.8%), 5 non-disabling strokes (5 patients, 3.8%), and 23 deaths (17.4%) were observed. No death was from a primary endpoint complication. At 6 months, the New York Heart Association class improved in 59% of patients, and 55% had LV end-systolic volume reduction of 15% or greater. Those patients enrolled after CRT non-response showed similar improvement with LVEP. CONCLUSIONS: The ALSYNC study demonstrates clinical feasibility, and provides an early indication of possible benefit and risk of LVEP. CLINICAL TRIAL: NCT01277783.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy
Khan, F. Z., Virdee, M. S., Palmer, C. R., Pugh, P. J., O'Halloran, D., Elsik, M., Read, P. A., Begley, D., Fynn, S. P., & Dutka, D. P. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.030 · Cited by 647 · cited 1×
“Therefore, the choice of LV pacing site is often a matter of implant expediency rather than physiological imperative and can result in suboptimal clinical outcome.(4) Surgical LV epicardial lead implant may be an alternative to CS LV lead implant, but it requires an invasive surgical procedure.”
Warfarin and Aspirin in Patients with Heart Failure and Sinus Rhythm
Homma, S., Thompson, J. L. P., Pullicino, P. M., Levin, B., Freudenberger, R. S., Teerlink, J. R., Ammon, S. E., Graham, S., Sacco, R. L., Mann, D. L., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202299 · Cited by 584 · cited 1×
“78 events per 100 patient-years).(13) Implantation of an LVEP lead may increase this risk.”
McAlister, F. A., Ezekowitz, J., Hooton, N., Vandermeer, B., Spooner, C., Dryden, D. M., Page, R. L., Hlatky, M. A., & Rowe, B. H. (2007) · JAMA · doi:10.1001/jama.297.22.2502 · Cited by 569 · cited 3×
“Cardiac resynchronization therapy (CRT) is a well-established treatment for heart failure patients with left ventricular (LV) systolic dysfunction and asynchronous LV contraction, restoring LV mechanical efficiency, improving patients’ quality of life, and reducing heart failure-related hospitalizations/mortality.(1,2…”
Ypenburg, C., van Bommel, R. J., Borleffs, C. J. W., Bleeker, G. B., Boersma, E., Schalij, M. J., & Bax, J. J. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.10.032 · Cited by 444 · cited 1×
“Of note, 33% of the patients showed ‘super-response’ at 6 months, as defined by an LVESV reduction of 30% or greater.(19) It was also noteworthy that patients who were non-responders to conventional epicardial CRT showed response to LVEP CRT.”
The problem of non-response to cardiac resynchronization therapy
Birnie, D. H., & Tang, A. S. (2006) · Current Opinion in Cardiology · doi:10.1097/01.hco.0000198983.93755.99 · Cited by 277 · cited 1×
“CRT device reprogramming to optimize atrioventricular as well as interventricular pacing output timing has been disappointing with large studies failing to demonstrate any enhanced clinical effectiveness.(7) There is evidence that the LV pacing site may be of critical importance in defining patient response,(4) althou…”
Derval, N., Steendijk, P., Gula, L. J., Deplagne, A., Laborderie, J., Sacher, F., Knecht, S., Wright, M., Nault, I., Ploux, S., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.045 · Cited by 268 · cited 1×
“LV epicardial pacing has been considered, but not in a controlled or prospective manner.(18) Given that limitation, there is evidence that LVEP offers greater LV functional benefit than does epicardial LV pacing.”
Garrigue, S., Jaïs, P., Espil, G., Labeque, J.-N., Hocini, M., Shah, D. C., Haïssaguerre, M., & Clementy, J. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01892-6 · Cited by 177 · cited 3×
“Garrigue et al.(8) studied 15 patients who had an epicardial lead implanted through the coronary sinus and compared them with 8 patients with LVEP leads placed by transseptal puncture following identification of unsuitable coronary sinus anatomy.”
Freudenberger, R. S., Hellkamp, A. S., Halperin, J. L., Poole, J., Anderson, J., Johnson, G., Mark, D. B., Lee, K. L., & Bardy, G. H. (2007) · Circulation · doi:10.1161/circulationaha.106.661397 · Cited by 169
Cited by
Avoiding non-responders to cardiac resynchronization therapy: a practical guide
Daubert, C., Behar, N., Martins, R. P., Mabo, P., & Leclercq, C. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw270 · Cited by 311
Self-citationCardiac Resynchronization Therapy With Wireless Left Ventricular Endocardial Pacing
Reddy, V. Y., Miller, M. A., Neuzil, P., Søgaard, P., Butter, C., Seifert, M., Delnoy, P. P., van Erven, L., Schalji, M., Boersma, L. V. A., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.059 · Cited by 214
“patients achieved an improvement of at least 1 NYHA functional class at 6 months (14).”
BackgroundStrocchi, M., Lee, A. W. C., Neic, A., Bouyssier, J., Gillette, K., Plank, G., Elliott, M. K., Gould, J., Behar, J. M., Sidhu, B., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.06.028 · Cited by 73
“Despite some advantages, LBP requires LVendocardial pacing, which can increase the risks of cerebrovascular accidents and embolic events.(29) To prevent these events, LBP could necessitate long-term anticoagulation that would need to be offset against any benefits.”
BackgroundStrocchi, M., Wijesuriya, N., Elliott, M. K., Gillette, K., Neic, A., Mehta, V., Vigmond, E. J., Plank, G., Rinaldi, C. A., & Niederer, S. A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.1049214 · Cited by 8
“BIV-endo pacing has emerged as an alternative to conventional CRT for patients who could not receive or did not respond to conventional CRT (Derval et al., 2010; Ginks et al., 2012; Behar et al., 2016; Morgan et al., 2016; Padeletti et al., 2016).”
Metadata
- Authors
- Morgan, J. M., Biffi, M., Gellér, L., Leclercq, C., Ruffa, F., Tung, S., Defaye, P., Yang, Z., Gerritse, B., van Ginneken, M., Yee, R., & Jais, P.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-01-18
- Volume
- 37
- Issue
- 27
- Pages
- 2118-2127
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2342124219
- Cited by
- 166
- References
- 17
- FWCI
- 19.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ALternate Site Cardiac ResYNChronization (ALSYNC): a prospective and multicentre study of left ventricular endocardial pacing for cardiac resynchronization therapy. https://app.cochat.ai/papers/10.1093/eurheartj/ehv723
- The paper
- Morgan, J. M., Biffi, M., Gellér, L., Leclercq, C., Ruffa, F., Tung, S., Defaye, P., Yang, Z., Gerritse, B., van Ginneken, M., Yee, R., & Jais, P. (2016). ALternate Site Cardiac ResYNChronization (ALSYNC): a prospective and multicentre study of left ventricular endocardial pacing for cardiac resynchronization therapy. European Heart Journal. https://doi.org/10.1093/eurheartj/ehv723
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.