Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 227

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diagnostic sensitivity of abdominal fat aspiration in cardiac amyloidosis

Open access
Quarta, Candida Cristina, Gonzalez-Lopez, Esther, Gilbertson, Janet A., Botcher, Nichola, Rowczenio, Dorota, Petrie, Aviva, Rezk, Tamer, Youngstein, Taryn, Mahmood, Shameem, Sachchithanantham, Sajitha, Lachmann, Helen J., Fontana, Marianna, Whelan, Carol J., Wechalekar, Ashutosh D., Hawkins, Philip N., Gillmore, Julian D. · 2017 · European Heart Journal

Abstract

Aims: Congo red staining of an endomyocardial biopsy is the diagnostic gold-standard in suspected cardiac amyloidosis (CA), but the procedure is associated with the risk, albeit small, of serious complications, and delay in diagnosis due to the requirement for technical expertise. In contrast, abdominal fat pad fine needle aspiration (FPFNA) is a simple, safe and well-established procedure in systemic amyloidosis, but its diagnostic sensitivity in patients with suspected CA remains unclear. Methods and results: We assessed the diagnostic sensitivity of FPFNA in 600 consecutive patients diagnosed with CA [216 AL amyloidosis, 113 hereditary transthyretin (ATTRm), and 271 wild-type transthyretin (ATTRwt) amyloidosis] at our Centre. Amyloid was detected on Congo red staining of FPFNAs in 181/216 (84%) patients with cardiac AL amyloidosis, including 100, 97, and 78% of those with a large, moderate, and small whole-body amyloid burden, respectively, as assessed by serum amyloid P (SAP) component scintigraphy (P < 0.001); the deposits were successfully typed as AL by immunohistochemistry in 102/216 (47%) cases. Amyloid was detected in FPFNAs of 51/113 (45%) patients with ATTRm CA, and only 42/271 (15%) cases with ATTRwt CA. Conclusions: FPFNA has reasonable diagnostic sensitivity in cardiac AL amyloidosis, particularly in patients with a large whole-body amyloid burden. Although the diagnostic sensitivity of FPFNA is substantially lower in transthyretin CA, particularly ATTRwt, it may nevertheless sometimes obviate the need for endomyocardial biopsy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehx047

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 227

Metadata

Authors
Quarta, C. C., Gonzalez-Lopez, E., Gilbertson, J. A., Botcher, N., Rowczenio, D., Petrie, A., Rezk, T., Youngstein, T., Mahmood, S., Sachchithanantham, S., Lachmann, H. J., Fontana, M., Whelan, C. J., Wechalekar, A. D., Hawkins, P. N., & Gillmore, J. D.
Venue
European Heart Journal
Published
2017-03-07
Volume
38
Issue
24
Pages
1905-1908
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2624652407
Cited by
227
References
1
FWCI
7.57
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic sensitivity of abdominal fat aspiration in cardiac amyloidosis. https://app.cochat.ai/papers/10.1093/eurheartj/ehx047
The paper
Quarta, C. C., Gonzalez-Lopez, E., Gilbertson, J. A., Botcher, N., Rowczenio, D., Petrie, A., Rezk, T., Youngstein, T., Mahmood, S., Sachchithanantham, S., Lachmann, H. J., Fontana, M., Whelan, C. J., Wechalekar, A. D., Hawkins, P. N., & Gillmore, J. D. (2017). Diagnostic sensitivity of abdominal fat aspiration in cardiac amyloidosis. European Heart Journal. https://doi.org/10.1093/eurheartj/ehx047

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.