Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 275

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Subclinical device-detected atrial fibrillation and stroke risk: a systematic review and meta-analysis

Mahajan, Rajiv, Perera, Tharani, Elliott, Adrian D, Twomey, Darragh J, Kumar, Sharath, Munwar, Dian A, Khokhar, Kashif B, Thiyagarajah, Anand, Middeldorp, Melissa E, Nalliah, Chrishan J, Hendriks, Jeroen M L, Kalman, Jonathan M, Lau, Dennis H, Sanders, Prashanthan·2018·European Heart Journal

Abstract

Aims: To determine stroke risk in subclinical atrial fibrillation (AF) and temporal association between subclinical AF and stroke. Methods and results: Pubmed/Embase was searched for studies reporting stroke in subclinical AF in patients with cardiac implantable electronic devices (CIEDs). After exclusions, 11 studies were analysed. Of these seven studies reported prevalence of subclinical AF, two studies reported association between subclinical and clinical AF, seven studies reported stroke risk in subclinical AF, and five studies reported temporal relationship between subclinical AF and stroke. Subclinical AF was noted after CIEDs implant in 35% [interquartile range (IQR) 34-42] of unselected patients with pacing indication over 1-2.5 years. The definition and cut-off duration (for stroke risk) of subclinical AF varied across studies. Subclinical AF was strongly associated with clinical AF (OR 5.7, 95% CI 4.0-8.0, P < 0.001, I2 = 0%). The annual stroke rate in patients with subclinical AF > defined cut-off duration was 1.89/100 person-year (95% CI 1.02-3.52) with 2.4-fold (95% CI 1.8-3.3, P < 0.001, I2 = 0%) increased risk of stroke as compared to patients with subclinical AF < cut-off duration (absolute risk was 0.93/100 person-year). Three studies provided mean CHADS2 score. In these studies, with mean CHADS2 score of 2.1 ± 0.1, subclinical AF was associated with annual stroke rate of 2.76/100 person-years (95% CI 1.46-5.23). After excluding patients without AF, only 17% strokes occurred in presence of ongoing AF. Subclinical AF was noted in 29% [IQR 8-57] within 30 days preceding stroke. Conclusion: Subclinical AF strongly predicts clinical AF and is associated with elevated absolute stroke risk albeit lower than risk described for clinical AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehx731

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 275

Metadata

Authors
Mahajan, R., Perera, T., Elliott, A. D., Twomey, D. J., Kumar, S., Munwar, D. A., Khokhar, K. B., Thiyagarajah, A., Middeldorp, M. E., Nalliah, C. J., Hendriks, J. M. L., Kalman, J. M., Lau, D. H., & Sanders, P.
Venue
European Heart Journal
Published
2018-01-10
Volume
39
Issue
16
Pages
1407-1415
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2784029422
Cited by
275
References
32
FWCI
5.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subclinical device-detected atrial fibrillation and stroke risk: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1093/eurheartj/ehx731
The paper
Mahajan, R., Perera, T., Elliott, A. D., Twomey, D. J., Kumar, S., Munwar, D. A., Khokhar, K. B., Thiyagarajah, A., Middeldorp, M. E., Nalliah, C. J., Hendriks, J. M. L., Kalman, J. M., Lau, D. H., & Sanders, P. (2018). Subclinical device-detected atrial fibrillation and stroke risk: a systematic review and meta-analysis. European Heart Journal. https://doi.org/10.1093/eurheartj/ehx731

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.