Continued vs. interrupted direct oral anticoagulants at the time of device surgery, in patients with moderate to high risk of arterial thrombo-embolic events (BRUISE CONTROL-2)
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Aims: Guidelines recommend warfarin continuation rather than heparin bridging for pacemaker and defibrillator surgery, after the BRUISE CONTROL trial demonstrated an 80% reduction in device pocket haematoma with this approach. However, direct oral anticoagulants (DOACs) are now used to treat the majority of patients with atrial fibrillation. We sought to understand the best strategy to manage the DOACs at the time of device surgery and specifically hypothesized that performing device surgery without DOAC interruption would result in a reduced haematoma rate. Methods and results: We randomly assigned patients with atrial fibrillation and CHA2DS2-VASc score ≥2, to continued vs. interrupted DOAC (dabigatran, rivaroxaban, or apixaban). The primary outcome was blindly evaluated, clinically significant device pocket haematoma: resulting in re-operation, interruption of anticoagulation, or prolonging hospital stay. In the continued arm, the median time between pre- and post-operative DOAC doses was 12 h; in the interrupted arm the median time was 72 h. Clinically significant haematoma occurred in of 7 of 328 (2.1%; 95% CI 0.9-4.3) patients in the continued DOAC arm and 7 of 334 (2.1%; 95% CI 0.9-4.3) patients in the interrupted DOAC arm (P = 0.97). Complications were uncommon, and included one stroke and one symptomatic pericardial effusion in each arm. Conclusions: These results suggest that, dependent on the clinical scenario, either management strategy (continued DOAC or interrupted DOAC) might be reasonable, at least for patients similar to those enrolled in our trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Idarucizumab for Dabigatran Reversal
Pollack, C. V., Reilly, P. A., Eikelboom, J., Glund, S., Verhamme, P., Bernstein, R. A., Dubiel, R., Huisman, M. V., Hylek, E. M., Kamphuisen, P. W., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1502000 · Cited by 1,552
Self-citationIdarucizumab for dabigatran reversal
Garrett, A. D., PharmD, & Bcps (2015) · Cited by 1,167
Poole, J. E., Gleva, M. J., Mela, T., Chung, M. K., Uslan, D. Z., Borge, R., Gottipaty, V., Shinn, T., Dan, D., Feldman, L. A., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.976076 · Cited by 790
National trends in ambulatory oral anticoagulant use
Barnes, G. D., Lucas, E., Alexander, G. C., & Goldberger, Z. D. (2015) · The American Journal of Medicine · doi:10.1016/j.amjmed.2015.05.044 · Cited by 598
Pacemaker or Defibrillator Surgery without Interruption of Anticoagulation
Birnie, D. H., Healey, J. S., Wells, G. A., Verma, A., Tang, A. S., Krahn, A. D., Simpson, C. S., Ayala-Paredes, F., Coutu, B., Leiria, T. L. L., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1302946 · Cited by 579
Self-citationHealey, J. S., Eikelboom, J., Douketis, J., Wallentin, L., Oldgren, J., Yang, S., Themeles, E., Heidbuchel, H., Avezum, A., Reilly, P., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.090464 · Cited by 541
Self-citationUninterrupted Dabigatran versus Warfarin for Ablation in Atrial Fibrillation
Calkins, H., Willems, S., Gerstenfeld, E. P., Verma, A., Schilling, R., Hohnloser, S. H., Okumura, K., Serota, H., Nordaby, M., Guiver, K., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1701005 · Cited by 430
Self-citationRaval, A. N., Cigarroa, J. E., Chung, M. K., Diaz-Sandoval, L. J., Diercks, D., Piccini, J. P., Jung, H. S., Washam, J. B., Welch, B. G., Zazulia, A. R., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000477 · Cited by 251
Trends in the prescription of novel oral anticoagulants in UK primary care
Loo, S. Y., Dell'Aniello, S., Huiart, L., & Renoux, C. (2017) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.13299 · Cited by 240
Cited by
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2023 ESC Guidelines for the management of endocarditis
Delgado, V., Ajmone Marsan, N., de Waha, S., Bonaros, N., Brida, M., Burri, H., Caselli, S., Doenst, T., Ederhy, S., Erba, P. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad193 · Cited by 1,754
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Perioperative Management of Antithrombotic Therapy
Douketis, J. D., Spyropoulos, A. C., Murad, M. H., Arcelus, J. I., Dager, W. E., Dunn, A. S., Fargo, R. A., Levy, J. H., Samama, C. M., Shah, S. H., et al. (2022) · CHEST · doi:10.1016/j.chest.2022.07.025 · Cited by 450
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · EP Europace · doi:10.1093/europace/euz246 · Cited by 423
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz296 · Cited by 318
Reversal of direct oral anticoagulants: Guidance from the Anticoagulation Forum
Cuker, A., Burnett, A., Triller, D., Crowther, M., Ansell, J., Van Cott, E. M., Wirth, D., & Kaatz, S. (2019) · American Journal of Hematology · doi:10.1002/ajh.25475 · Cited by 315
Chung, M. K., Refaat, M., Shen, W.-K., Kutyifa, V., Cha, Y.-M., Di Biase, L., Baranchuk, A., Lampert, R., Natale, A., Fisher, J., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.02.025 · Cited by 252
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa010 · Cited by 222
Burri, H., Starck, C., Auricchio, A., Biffi, M., Burri, M., D’Avila, A., Deharo, J.-C., Glikson, M., Israel, C., Lau, C.-P., et al. (2021) · EP Europace · doi:10.1093/europace/euaa367 · Cited by 219
“0% depending on definition and factors such as anticoagulation regimen.(10,11,17,118,119,181) It is associated with an approximately ninefold increased risk of infection.”
BackgroundBaddour, L. M., Esquer Garrigos, Z., Rizwan Sohail, M., Havers-Borgersen, E., Krahn, A. D., Chu, V. H., Radke, C. S., Avari-Silva, J., El-Chami, M. F., Miro, J. M., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001187 · Cited by 179
Risk Factors for Infections Involving Cardiac Implanted Electronic Devices
Birnie, D. H., Wang, J., Alings, M., Philippon, F., Parkash, R., Manlucu, J., Angaran, P., Rinne, C., Coutu, B., Low, R. A., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.09.060 · Cited by 173
Self-citationLi, M., Kim, J. B., Sastry, B. K. S., & Chen, M. (2024) · The Lancet · doi:10.1016/s0140-6736(24)01098-5 · Cited by 169
Metadata
- Authors
- Birnie, D. H., Healey, J. S., Wells, G. A., Ayala-Paredes, F., Coutu, B., Sumner, G. L., Becker, G., Verma, A., Philippon, F., Kalfon, E., Eikelboom, J., Sandhu, R. K., Nery, P. B., Lellouche, N., Connolly, S. J., Sapp, J., & Essebag, V.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-07-25
- Volume
- 39
- Issue
- 44
- Pages
- 3973-3979
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2883546078
- Cited by
- 192
- References
- 23
- FWCI
- 14.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.