Transcatheter mitral valve repair for functional mitral regurgitation using the Cardioband system: 1 year outcomes

Open access
Messika-Zeitoun, David, Nickenig, Georg, Latib, Azeem, Kuck, Karl-Heinz, Baldus, Stephan, Schueler, Robert, La Canna, Giovanni, Agricola, Eustachio, Kreidel, Felix, Huntgeburth, Michael, Zuber, Michel, Verta, Patrick, Grayburn, Paul, Vahanian, Alec, Maisano, Francesco · 2019 · European Heart Journal
Cited by 165

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Aims: The Cardioband™ (Edwards Lifesciences) is a transcatheter implant designed to reduce mitral annulus size and mitral regurgitation (MR) severity. We report the 1-year outcomes of consecutive patients who underwent the Cardioband procedure between 2013 and 2016. Methods and results: Sixty patients with moderate or severe secondary MR (72 ± 7 years, 60% ischaemic origin) on guideline-recommended medical therapy were treated and analyzed at 11 European institutions. There were two in-hospital deaths (none device-related), one stroke, two coronary artery complications, and one tamponade. Anchor disengagement, observed in 10 patients (all but one in the first half of the population), resulted in device inefficacy in five patients and led to device modification half way through the study to mitigate this issue. Technical, device, and procedural successes, assessed based on Mitral Valve Academic Research Consortium (MVARC) criteria, were 97% (58/60), 72% (43/60), and 68% (41/60), respectively. At 1-year, overall survival, survival free of readmission for heart failure, and survival free of reintervention (performed in seven patients) were 87%, 66%, and 78%, respectively. In the overall population, MR grade at 12 months was moderate or less 61% and moderate or less in 95% of the 39 patients who underwent a transthoracic echocardiography at 1-year [but worsened by at least one grade in 11 patients (22%)]. Functional status (79% vs. 14% in New York Heart Association Class I/II), quality of life (-19 points on the Minnesota Living with Heart Failure Questionnaire score), and exercise capacity (+58 m by 6MWT) improved significantly (all P < 0.01). Conclusion: In this multicentre trial, the Cardioband mitral system demonstrated reasonable performance and safety. At 1 year, most patients had moderate or less MR and experienced significant functional improvements. A randomized controlled trial is underway to demonstrate the impact of Cardioband in patients on guideline-directed medical therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehy424

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 165

Metadata

Authors
Messika-Zeitoun, D., Nickenig, G., Latib, A., Kuck, K.-H., Baldus, S., Schueler, R., La Canna, G., Agricola, E., Kreidel, F., Huntgeburth, M., Zuber, M., Verta, P., Grayburn, P., Vahanian, A., & Maisano, F.
Venue
European Heart Journal
Published
2018-08-16
Volume
40
Issue
5
Pages
466-472
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2885627232
Cited by
165
References
21
FWCI
18.75
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter mitral valve repair for functional mitral regurgitation using the Cardioband system: 1 year outcomes. https://app.cochat.ai/papers/10.1093/eurheartj/ehy424
The paper
Messika-Zeitoun, D., Nickenig, G., Latib, A., Kuck, K.-H., Baldus, S., Schueler, R., La Canna, G., Agricola, E., Kreidel, F., Huntgeburth, M., Zuber, M., Verta, P., Grayburn, P., Vahanian, A., & Maisano, F. (2019). Transcatheter mitral valve repair for functional mitral regurgitation using the Cardioband system: 1 year outcomes. European Heart Journal. https://doi.org/10.1093/eurheartj/ehy424

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.