Diagnostic performance of angiography-derived fractional flow reserve: a systematic review and Bayesian meta-analysis
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Aims: Pressure-wire assessment of coronary stenosis is considered the invasive reference standard for detection of ischaemia-generating lesions. Recently, methods to estimate the fractional flow reserve (FFR) from conventional angiography without the use of a pressure wire have been developed, and were shown to have an excellent diagnostic accuracy. The present systematic review and meta-analysis aimed at determining the diagnostic performance of angiography-derived FFR for the diagnosis of haemodynamically significant coronary artery disease. Methods and results: A systematic review and meta-analysis of studies assessing the diagnostic performance of angiography-derived FFR systems were performed. The primary outcome of interest was pooled sensitivity and specificity. Thirteen studies comprising 1842 vessels were included in the final analysis. A Bayesian bivariate meta-analysis yielded a pooled sensitivity of 89% (95% credible interval 83-94%), specificity of 90% (95% credible interval 88-92%), positive likelihood ratio (+LR) of 9.3 (95% credible interval 7.3-11.7) and negative likelihood ratio (-LR) of 0.13 (95% credible interval 0.07-0.2). The summary area under the receiver-operating curve was 0.84 (95% credible interval 0.66-0.94). Meta-regression analysis did not find differences between the methods for pressure-drop calculation (computational fluid dynamics vs. mathematical formula), type of analysis (on-line vs. off-line) or software packages. Conclusion: The accuracy of angiography-derived FFR was good to detect haemodynamically significant lesions with pressure-wire measured FFR as a reference. Computational approaches and software packages did not influence the diagnostic accuracy of angiography-derived FFR. A diagnostic strategy trial with angiography-derived FFR evaluating clinical endpoints is warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Shamseer, L., Moher, D., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., Stewart, L. A., & the PRISMA-P Group (2015) · BMJ · doi:10.1136/bmj.g7647 · Cited by 13,120
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
Self-citation2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Self-citationA hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505 · cited 1×
“Test performance was evaluated using summary receiver operator curves (SROC) using the Rutter and Gatsonis’s method.(20) A bivariate meta-regression model was cast to evaluate the effect of the defined covariates on sensitivity and specificity.”
MethodAl-Lamee, R., Thompson, D., Dehbi, H.-M., Sen, S., Tang, K., Davies, J., Keeble, T., Mielewczik, M., Kaprielian, R., Malik, I. S., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(17)32714-9 · Cited by 1,025 · cited 1×
“wire can result in complications such as vessel dissection and myocardial infarction.(33) One of the theoretical advantages of angiographyderived FFR would be the reduction in adverse events related to the introduction of the wire in the coronary vessel.”
BackgroundPatel, M. R., Calhoon, J. H., Dehmer, G. J., Grantham, J. A., Maddox, T. M., Maron, D. J., & Smith, P. K. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.001 · Cited by 620
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Tu, S., Westra, J., Yang, J., von Birgelen, C., Ferrara, A., Pellicano, M., Nef, H., Tebaldi, M., Murasato, Y., Lansky, A., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.07.013 · Cited by 591 · cited 13×
“The high accuracy of the derivation of FFR from conventional angiography, particularly after the exclusion of the zone of uncertainty, is sufficient to trigger a clinical outcomes trial testing the diagnostic strategy of angiography-derived FFR.”
MethodInfluentialSelf-citationPatel, M. R., Calhoon, J. H., Dehmer, G. J., Grantham, J. A., Maddox, T. M., Maron, D. J., & Smith, P. K. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.034 · Cited by 493
Gould, K. L. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90165-0 · Cited by 460
Tu, S., Barbato, E., Köszegi, Z., Yang, J., Sun, Z., Holm, N. R., Tar, B., Li, Y., Rusinaru, D., Wijns, W., et al. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.03.004 · Cited by 361
Self-citationEvolving concepts of angiogram: fractional flow reserve discordances in 4000 coronary stenoses
Toth, G., Hamilos, M., Pyxaras, S., Mangiacapra, F., Nelis, O., De Vroey, F., Di Serafino, L., Muller, O., Van Mieghem, C., Wyffels, E., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu094 · Cited by 329 · cited 1×
“%DS = Reference vessel diameter - Minimal lumen diameter / Reference vessel diameter)] has been shown to have only modest correlation with physiologic indexes of myocardial ischaemia.(4) Discrepancy between anatomy and physiology is found in approximately 20% of the lesions with QCA diameter stenosis >70% and in half…”
MethodSelf-citationVisual-Functional Mismatch Between Coronary Angiography and Fractional Flow Reserve
Park, S.-J., Kang, S.-J., Ahn, J.-M., Shim, E. B., Kim, Y.-T., Yun, S.-C., Song, H., Lee, J.-Y., Kim, W.-J., Park, D.-W., et al. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.07.007 · Cited by 329 · cited 1×
“Discrepancy between anatomy and physiology is found in approximately 20% of the lesions with QCA diameter stenosis >70% and in half of lesions with diameter stenosis between 50% and 70% with respect to fractional flow reserve (FFR).(5,6) Moreover, a recent study indicates that visual analysis might be more accurate th…”
BackgroundKirkeeide, R. L., Gould, K. L., & Parsel, L. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80266-2 · Cited by 325
Park, H., Heo, R., Hartaigh, B. Ó., Cho, I., Gransar, H., Nakazato, R., Leipsic, J. A., Mancini, G. B. J., Koo, B., Otake, H., et al. (2015) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2014.11.002 · Cited by 310 · cited 10×
“The high accuracy of the derivation of FFR from conventional angiography, particularly after the exclusion of the zone of uncertainty, is sufficient to trigger a clinical outcomes trial testing the diagnostic strategy of angiography-derived FFR.”
MethodInfluentialMorris, P. D., Ryan, D., Morton, A. C., Lycett, R., Lawford, P. V., Hose, D. R., & Gunn, J. P. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.08.024 · Cited by 270 · cited 3×
“*distal point FFR. Reproduced with permissions of Tu et al.14,16; Papafaklis et al.15; Morris et al.22; Trobs et al.23 and Kornowski et al.24.”
BackgroundGIANT RIGHT CORONARY ARTERY ANEURYSM ASSOCIATED WITH A CORONARY CAMERAL FISTULA TO THE RIGHT ATRIUM
Bierzynski, A., Pak, Y., Bhusri, S., & Kronzon, I. (2017) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(17)35601-2 · Cited by 235
Jelicic Kadic, A., Vucic, K., Dosenovic, S., Sapunar, D., & Puljak, L. (2016) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2016.01.002 · Cited by 222 · cited 1×
“8, Boston, MA, USA).(21) Digitized values were rounded to 2 decimal places.”
BackgroundValidation Study of Image-Based Fractional Flow Reserve During Coronary Angiography
Pellicano, M., Lavi, I., Bruyne, B. D., Assa, H. V., Assali, A. R., Valtzer, O., Lotringer, Y., Weisz, G., Almagor, Y., Xaplanteris, P., et al. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.116.005259 · Cited by 119 · cited 2×
“and Pellicano et al.(25,27,30) showed that the QFR and FFRangio algorithms had higher diagnostic accuracy compared with 3D-QCA diameter stenosis to detect significant lesions.”
ResultSelf-citationTröbs, M., Achenbach, S. S., Röther, J., Redel, T., Scheuering, M., Winneberger, D., Klingenbeck, K., Lucian Mihai, I. T. U., Passerini, T., Kamen, A., et al. (2015) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.10.008 · Cited by 84 · cited 4×
“; Trobs et al.(23) and Kornowski et al.”
BackgroundInfluentialState of the art: coronary angiography
Collet, C. A., Grundeken, M. J., Asano, T., Onuma, Y., Wijns, W. C., & Serruys, P. W. J. C. (2017) · EuroIntervention · doi:10.4244/eij-d-17-00465 · Cited by 58 · cited 1×
“Furthermore, 3D-QCA enables to construct a patient-specific coronary geometry that can be further processed by computational fluid dynamics (CFD) to perform blood flow simulations that can derive endothelial shear stress and pressure drop.(13) The application of 3D-QCA integrating anatomic parameters and accounting fo…”
MethodSelf-citationYazaki, K., Otsuka, M., Kataoka, S., Kahata, M., Kumagai, A., Inoue, K., Koganei, H., Enta, K., & Ishii, Y. (2017) · Circulation Journal · doi:10.1253/circj.cj-16-1261 · Cited by 57
Adjedj, J., Xaplanteris, P., Tóth, G. G., Ferrara, A., Pellicano, M., Ciccarelli, G., Floré, V., Barbato, E., & Bruyne, B. D. (2017) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.117.006243 · Cited by 52 · cited 1×
“Moreover, a recent study indicates that visual analysis might be more accurate than QCA diameter stenosis.(7) This fact has limited the usefulness of diameter stenosis and led to the recommendation to use pressure-wire derived metrics of functional stenosis significance to define the need for revascularization, partic…”
BackgroundBayesian bivariate meta‐analysis of diagnostic test studies with interpretable priors
Guo, J., Riebler, A., & Rue, H. (2017) · Statistics in Medicine · doi:10.1002/sim.7313 · Cited by 48 · cited 1×
“The prior distribution specified was the penalized complexity priors.(19) Sensitivity analyses with different prior distributions using inverse gamma, truncated normal and uniform prior distribution for the covariance, and using prior normal distribution for the correlation were performed.”
Method
Cited by
Gijsen, F., Katagiri, Y., Barlis, P., Bourantas, C., Collet, C., Coskun, U., Daemen, J., Dijkstra, J., Edelman, E., Evans, P., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz551 · Cited by 315
Self-citationCollet, C., Sonck, J., Vandeloo, B., Mizukami, T., Roosens, B., Lochy, S., Argacha, J.-F., Schoors, D., Colaiori, I., Di Gioia, G., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.07.072 · Cited by 265
Self-citationTu, S., Ding, D., Chang, Y., Li, C., Wijns, W., & Xu, B. (2021) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.29592 · Cited by 206
Self-citation
Metadata
- Authors
- Collet, C., Onuma, Y., Sonck, J., Asano, T., Vandeloo, B., Kornowski, R., Tu, S., Westra, J., Holm, N. R., Xu, B., de Winter, R. J., Tijssen, J. G., Miyazaki, Y., Katagiri, Y., Tenekecioglu, E., Modolo, R., Chichareon, P., Cosyns, B., Schoors, D., Roosens, B., Lochy, S., Argacha, J.-F., van Rosendael, A., Bax, J., Reiber, J. H. C., Escaned, J., De Bruyne, B., Wijns, W., & Serruys, P. W.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-08-20
- Volume
- 39
- Issue
- 35
- Pages
- 3314-3321
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2888716150
- Cited by
- 165
- References
- 26
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.