Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 329

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Evolving concepts of angiogram: fractional flow reserve discordances in 4000 coronary stenoses

Toth, Gabor, Hamilos, Michalis, Pyxaras, Stylianos, Mangiacapra, Fabio, Nelis, Olivier, De Vroey, Frederic, Di Serafino, Luigi, Muller, Olivier, Van Mieghem, Carlos, Wyffels, Eric, Heyndrickx, Guy R., Bartunek, Jozef, Vanderheyden, Marc, Barbato, Emanuele, Wijns, William, De Bruyne, Bernard·2014·European Heart Journal

Abstract

AIMS: The present analysis addresses the potential clinical and physiologic significance of discordance in severity of coronary artery disease between the angiogram and fractional flow reserve (FFR) in a large and unselected patient population. METHODS AND RESULTS: Between September 1999 and December 2011, FFR and percent diameter stenosis (DS) as assessed by quantitative coronary angiography were obtained in 2986 patients (n = 4086 coronary stenoses), in whom at least one stenosis was of intermediate angiographic severity. Fractional flow reserve correlated slightly but significantly with DS [-0.38 (95% CI: -0.41; -0.36); P < 0.001]. The sensitivity, specificity, and diagnostic accuracy of a ≥ 50% DS for predicting FFR ≤ 0.80 were 61% (95% CI: 59; 63), 67% (95% CI: 65; 69), and 0.64 (95% CI: 0.56; 0.72), respectively. In different anatomical settings, sensitivity and specificity showed marked variations between 35 to 74% and 58 to 76%, respectively, resulting in a discordance in 35% of all cases for these thresholds. For an angiographic threshold of 70% DS, the diagnostic performance by the Youden's index decreased from 0.28 to 0.11 for the overall population. CONCLUSION: The data confirm that one-third of a large patient population shows discordance between angiogram ≥ 50%DS and FFR ≤ 0.8 thresholds of stenosis severity. Left main stenoses are often underestimated by the classical 50% DS cut-off compared with FFR. This discordance offers physiologic insights for future trials. It is hypothesized that the discordance between angiography and FFR is related to technical limitations, such as imprecise luminal border detection by angiography, as well as to physiologic factors, such as variable minimal microvascular resistance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehu094

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

See all 329

Metadata

Authors
Toth, G., Hamilos, M., Pyxaras, S., Mangiacapra, F., Nelis, O., De Vroey, F., Di Serafino, L., Muller, O., Van Mieghem, C., Wyffels, E., Heyndrickx, G. R., Bartunek, J., Vanderheyden, M., Barbato, E., Wijns, W., & De Bruyne, B.
Venue
European Heart Journal
Published
2014-03-18
Volume
35
Issue
40
Pages
2831-2838
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2148958558
Cited by
329
References
37
FWCI
25.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evolving concepts of angiogram: fractional flow reserve discordances in 4000 coronary stenoses. https://app.cochat.ai/papers/10.1093/eurheartj/ehu094
The paper
Toth, G., Hamilos, M., Pyxaras, S., Mangiacapra, F., Nelis, O., De Vroey, F., Di Serafino, L., Muller, O., Van Mieghem, C., Wyffels, E., Heyndrickx, G. R., Bartunek, J., Vanderheyden, M., Barbato, E., Wijns, W., & De Bruyne, B. (2014). Evolving concepts of angiogram: fractional flow reserve discordances in 4000 coronary stenoses. European Heart Journal. https://doi.org/10.1093/eurheartj/ehu094

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.