The DOI matches its Crossref record.
Invasive left ventricle pressure–volume analysis: overview and practical clinical implications
Open accessAbstract
Ventricular pressure–volume (PV) analysis is the reference method for the study of cardiac mechanics. Advances in calibration algorithms and measuring techniques brought new perspectives for its application in different research and clinical settings. Simultaneous PV measurement in the heart chambers offers unique insights into mechanical cardiac efficiency. Beat to beat invasive PV monitoring can be instrumental in the understanding and management of heart failure, valvular heart disease, and mechanical cardiac support. This review focuses on intra cardiac left ventricular PV analysis principles, interpretation of signals, and potential clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The PV loops were characterized by two distinct filling and ejection phases separated by rapid vertical isovolumetric phases, as observed in the classic PV loop of the native ventricle.
“Similarly, the PV loops were characterized by two distinct filling and ejection phases that are separated by rapid vertical isovolumetric phases (Fig. 4G), as it is observed in the classic PV loop of the native ventricle (15).”
From Engineering a living cardiac pump on a chip using high-precision fabrication (2022) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 47
- Kuhtz-Buschbeck, 2018, Rediscovery of Otto Frank's contribution to science, J Mol Cell Cardiol, 119, 96, 10.1016/j.yjmcc.2018.04.017 · DOI
- Suga, 1990, Ventricular energetics, Physiol Rev, 70, 247, 10.1152/physrev.1990.70.2.247 · DOI
- Baan, 1992, Ventricular pressure-volume relations in vivo, Eur Heart J, 13, 2, 10.1093/eurheartj/13.suppl_E.2 · DOI
- van der Velde, 1992, Left ventricular segmental volume by conductance catheter and Cine-CT, Eur Heart J, 13, 15, 10.1093/eurheartj/13.suppl_E.15 · DOI
- Steendijk, 2004, Quantification of left ventricular mechanical dyssynchrony by conductance catheter in heart failure patients, Am J Physiol Heart Circ Physiol, 286, H723, 10.1152/ajpheart.00555.2003 · DOI
- Chen, 2001, Noninvasive single-beat determination of left ventricular end-systolic elastance in humans, J Am Coll Cardiol, 38, 2028, 10.1016/S0735-1097(01)01651-5 · DOI
- Klotz, 2007, A computational method of prediction of the end-diastolic pressure-volume relationship by single beat, Nat Protoc, 2, 2152, 10.1038/nprot.2007.270 · DOI
- Cohen-Solal, 1994, Left ventricular-arterial coupling in systemic hypertension: analysis by means of arterial effective and left ventricular elastances, J Hypertens, 12, 591, 10.1097/00004872-199405000-00013 · DOI
- Schreuder, 1997, Left ventricular pressure-volume relationships before and after cardiomyoplasty in patients with heart failure, Circulation, 96, 2978, 10.1161/01.CIR.96.9.2978 · DOI
- Schreuder, 2000, Acute and short-term effects of partial left ventriculectomy in dilated cardiomyopathy: assessment by pressure-volume loops, J Am Coll Cardiol, 36, 2104, 10.1016/S0735-1097(00)01036-6 · DOI
- Burkhoff, 2005, Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers, Am J Physiol Heart Circ Physiol, 289, H501, 10.1152/ajpheart.00138.2005 · DOI
- Schreuder, 2005, Beat-to-beat effects of intraaortic balloon pump timing on left ventricular performance in patients with low ejection fraction, Ann Thorac Surg, 79, 872, 10.1016/j.athoracsur.2004.07.073 · DOI
- Schreuder, 2005, Acute decrease of left ventricular mechanical dyssynchrony and improvement of contractile state and energy efficiency after left ventricular restoration, J Thorac Cardiovasc Surg, 129, 138, 10.1016/j.jtcvs.2004.03.057 · DOI
- Schreuder, 2005, Automatic intraaortic balloon pump timing using an intrabeat dicrotic notch prediction algorithm, Ann Thorac Surg, 79, 1017, 10.1016/j.athoracsur.2004.07.074 · DOI
- de Roest, 2013, Prediction of long-term outcome of cardiac resynchronization therapy by acute pressure-volume loop measurements, Eur J Heart Fail, 15, 299, 10.1093/eurjhf/hfs190 · DOI
- Burkhoff, 2015, Hemodynamics of mechanical circulatory support, J Am Coll Cardiol, 66, 2663, 10.1016/j.jacc.2015.10.017 · DOI
- Chen, 1998, Coupled systolic-ventricular and vascular stiffening with age: implications for pressure regulation and cardiac reserve in the elderly, J Am Coll Cardiol, 32, 1221, 10.1016/S0735-1097(98)00374-X · DOI
- Burkhoff, 1985, Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts, Circulation, 72, 440, 10.1161/01.CIR.72.2.440 · DOI
- Little, 2005, Diastolic dysfunction beyond distensibility: adverse effects of ventricular dilatation, Circulation, 112, 2888, 10.1161/CIRCULATIONAHA.105.578161 · DOI
- De Tombe, 1993, Ventricular stroke work and efficiency both remain nearly optimal despite altered vascular loading, Am J Physiol, 264, H1817
- Burkhoff, 2012, The science behind percutaneous hemodynamic support: a review and comparison of support strategies, Catheter Cardiovasc Interv, 80, 816, 10.1002/ccd.24421 · DOI
- Westermann, 2008, Role of left ventricular stiffness in heart failure with normal ejection fraction, Circulation, 117, 2051, 10.1161/CIRCULATIONAHA.107.716886 · DOI
- Hay, 2005, Role of impaired myocardial relaxation in the production of elevated left ventricular filling pressure, Am J Physiol Heart Circ Physiol, 288, H1203, 10.1152/ajpheart.00681.2004 · DOI
- Hoole, 2010, Stunning and cumulative left ventricular dysfunction occurs late after coronary balloon occlusion in humans insights from simultaneous coronary and left ventricular hemodynamic assessment, JACC Cardiovasc Interv, 3, 412, 10.1016/j.jcin.2009.12.014 · DOI
- Ladwiniec, 2016, Diastolic backward-traveling decompression (suction) wave correlates with simultaneously acquired indices of diastolic function and is reduced in left ventricular stunning, Circ Cardiovasc Interv, 9, 10.1161/CIRCINTERVENTIONS.116.003779 · DOI
- Bunnell, 1965, Left ventricular function derived from the pressure-volume diagram, Am J Med, 39, 881, 10.1016/0002-9343(65)90110-5 · DOI
- Regeer, 2016, Left ventricular reverse remodeling after aortic valve surgery for acute versus chronic aortic regurgitation, Echocardiography, 33, 1458, 10.1111/echo.13295 · DOI
- Wisenbaugh, 1984, Differences in myocardial performance and load between patients with similar amounts of chronic aortic versus chronic mitral regurgitation, J Am Coll Cardiol, 3, 916, 10.1016/S0735-1097(84)80349-6 · DOI
- Gaasch, 2008, Left ventricular response to mitral regurgitation: implications for management, Circulation, 118, 2298, 10.1161/CIRCULATIONAHA.107.755942 · DOI
- Pibarot, 2018, Post-TAVR heart failure, Structural Heart, 2, 286, 10.1080/24748706.2018.1456705 · DOI
- Dupuis, 2017, Forward left ventricular ejection fraction: a simple risk marker in patients with primary mitral regurgitation, J Am Heart Assoc, 6, 10.1161/JAHA.117.006309 · DOI
- Schrage, 2018, Distinct hemodynamic changes after interventional mitral valve edge-to-edge repair in different phenotypes of heart failure: an integrated hemodynamic analysis, J Am Heart Assoc, 7, 10.1161/JAHA.117.007963 · DOI
- Gaemperli, 2013, Real-time left ventricular pressure-volume loops during percutaneous mitral valve repair with the MitraClip system, Circulation, 127, 1018, 10.1161/CIRCULATIONAHA.112.135061 · DOI
- Liu, 1992, Reduced left ventricular compliance in human mitral stenosis. Role of reversible internal constraint, Circulation, 85, 1447, 10.1161/01.CIR.85.4.1447 · DOI
- Borlaug, 2011, Invasive hemodynamic assessment in heart failure, Cardiol Clin, 29, 269, 10.1016/j.ccl.2011.03.003 · DOI
- Kawaguchi, 2003, Combined ventricular systolic and arterial stiffening in patients with heart failure and preserved ejection fraction: implications for systolic and diastolic reserve limitations, Circulation, 107, 714, 10.1161/01.CIR.0000048123.22359.A0 · DOI
- Penicka, 2010, Heart failure with preserved ejection fraction in outpatients with unexplained dyspnea: a pressure-volume loop analysis, J Am Coll Cardiol, 55, 1701, 10.1016/j.jacc.2009.11.076 · DOI
- Asanoi, 1989, Ventriculoarterial coupling in normal and failing heart in humans, Circ Res, 65, 483, 10.1161/01.RES.65.2.483 · DOI
- Brutsaert, 1987, Nonuniformity: a physiologic modulator of contraction and relaxation of the normal heart, J Am Coll Cardiol, 9, 341, 10.1016/S0735-1097(87)80387-X · DOI
- Lieberman, 2006, Ventricular pacing lead location alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction, J Am Coll Cardiol, 48, 1634, 10.1016/j.jacc.2006.04.099 · DOI
- Daubert, 2017, Avoiding non-responders to cardiac resynchronization therapy: a practical guide, Eur Heart J, 38, 1463
- Schreuder, 1995, Beat-to-beat analysis of left ventricular pressure-volume relation and stroke volume by conductance catheter and aortic Modelflow in cardiomyoplasty patients, Circulation, 91, 2010, 10.1161/01.CIR.91.7.2010 · DOI
- Burkhoff, 2006, Surgical ventricular remodeling: a balancing act on systolic and diastolic properties, J Thorac Cardiovasc Surg, 132, 459, 10.1016/j.jtcvs.2006.04.045 · DOI
- Artrip, 2001, Left ventricular volume reduction surgery for heart failure: a physiologic perspective, J Thorac Cardiovasc Surg, 122, 775, 10.1067/mtc.2001.116208 · DOI
- Neumann, 2019, ESC/EACTS Guidelines on myocardial revascularization, Eur Heart J, 40, 87, 10.1093/eurheartj/ehy394 · DOI · Paper page
- den Uil, 2017, A Niche indication for intra-aortic balloon pump counterpulsation: aortic valve opening in a surgically vented left ventricle on venoarterial ECMO, JACC Cardiovasc Interv, 10, e133, 10.1016/j.jcin.2017.04.011 · DOI
- Ponikowski, 2016, 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: the Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC)Developed with the special contribution of the Heart Failure Association (HFA) of the ESC, Eur Heart J, 37, 2129, 10.1093/eurheartj/ehw128 · DOI · Paper page
Cited by
Sorted by citations
Myocardial Work in Echocardiography
Marzlin, N., Hays, A. G., Peters, M., Kaminski, A., Roemer, S., O’Leary, P., Kroboth, S., Harland, D. R., Khandheria, B. K., Tajik, A. J., et al. (2023) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.122.014419 · Cited by 121
Engineering a living cardiac pump on a chip using high-precision fabrication
Michas, C., Karakan, M. Ç., Nautiyal, P., Seidman, J. G., Seidman, C. E., Agarwal, A., Ekinci, K., Eyckmans, J., White, A. E., & Chen, C. S. (2022) · Science Advances · doi:10.1126/sciadv.abm3791 · Cited by 82
“4 of 12 work of generating flow against the pressure gradient and are a valuable clinical metric for the assessment of cardiac health that would greatly enhance the modeling power of in vitro models (15).”
BackgroundInfluential
Metadata
- Authors
- Bastos, M. B., Burkhoff, D., Maly, J., Daemen, J., den Uil, C. A., Ameloot, K., Lenzen, M., Mahfoud, F., Zijlstra, F., Schreuder, J. J., & Van Mieghem, N. M.
- Affiliations
- Erasmus MC (NL)
- Cardiovascular Research Foundation (US)
- Department of Cardiac and Transplant Surgery , IKEM, Prague, Czech Republic
- Universitätsklinikum des Saarlandes (DE)
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Centre , Office Nt 645, Dr Molewaterplein 40 3015 GD, Rotterdam, The Netherlands
- ORCID
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-08-21
- Volume
- 41
- Issue
- 12
- Pages
- 1286-1297
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- PMC
- PMC7084193
- OpenAlex
- W2969787468
- Cited by
- 237
- References
- 0
- Citations by year
- 2026: 34 · 2025: 36 · 2024: 46 · 2023: 43 · 2022: 37 · 2021: 25 · 2020: 15
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- European Heart Journal (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion, other-oa)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion, other-oa)
- RePub (Erasmus University Rotterdam) (submittedVersion, other-oa)
- RePub (Erasmus University Rotterdam) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- cardiac mechanics, invasive hemodynamic monitoring, heart failure, valvular heart disease, mechanical circulatory support
- MeSH terms
- Cardiac Volume, Heart, Heart Failure, Heart Ventricles, Humans, Myocardial Contraction, Stroke Volume, Ventricular Function, Left, Ventricular Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review