The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Patient Selection for Left Ventricular Assist Devices
Open accessAbstract
Heart transplantation (HTx) improves symptoms and prolongs life in advanced heart failure (HF), but organ supply is limited. In recent years, mechanical circulatory support and specifically implantable left ventricular assist devices (LVADs) have undergone technical improvements, and outcomes have improved dramatically. Left ventricular assist devices are now viable options for patients with severe HF as bridge to transplantation, destination therapy, or as bridge to recovery. Many believe that LVADs may soon provide outcomes similar to, or better than, HTx, launching a new era of end-stage HF management. The key to improving outcomes is patient selection, but the field is changing rapidly and guidelines and consensus are limited. This review summarizes recent reports of predictors of poor outcomes and provides an overview of selection for LVAD therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773
WRITING COMMITTEE MEMBERS, Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.167586 · Cited by 2,251
Cited by
Crespo-Leiro, M. G., Metra, M., Lund, L. H., Milicic, D., Costanzo, M. R., Filippatos, G., Gustafsson, F., Tsui, S., Barge-Caballero, E., De Jonge, N., et al. (2018) · European Journal of Heart Failure · doi:10.1002/ejhf.1236 · Cited by 880
Self-citationChow, S. L., Maisel, A. S., Anand, I., Bozkurt, B., de Boer, R. A., Felker, G. M., Fonarow, G. C., Greenberg, B., Januzzi, J. L., Kiernan, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000490 · Cited by 601
2010 Focused Update of ESC Guidelines on device therapy in heart failure
Authors/Task Force Members, Dickstein, K., Vardas, P. E., Auricchio, A., Daubert, J.-C., Linde, C., McMurray, J., Ponikowski, P., Priori, S. G., Sutton, R., et al. (2010) · EP Europace · doi:10.1093/europace/euq392 · Cited by 593
Authors/Task Force Members, Dickstein, K., Vardas, P. E., Auricchio, A., Daubert, J.-C., Linde, C., McMurray, J., Ponikowski, P., Priori, S. G., Sutton, R., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq337 · Cited by 445
2019 EACTS Expert Consensus on long-term mechanical circulatory support
Potapov, E. V., Antonides, C., Crespo-Leiro, M. G., Combes, A., Färber, G., Hannan, M. M., Kukucka, M., de Jonge, N., Loforte, A., Lund, L. H., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz098 · Cited by 399
Self-citation
Metadata
- Authors
- Lund, L. H., Matthews, J., & Aaronson, K.
- Venue
- European Journal of Heart Failure
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-04-21
- Volume
- 12
- Issue
- 5
- Pages
- 434-443
- ISSN
- 1388-9842 (ISSN-L)
- 1879-0844
- OpenAlex
- W2098181425
- Cited by
- 180
- References
- 2
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient Selection for Left Ventricular Assist Devices. https://app.cochat.ai/papers/10.1093/eurjhf/hfq006
- The paper
- Lund, L. H., Matthews, J., & Aaronson, K. (2010). Patient Selection for Left Ventricular Assist Devices. European Journal of Heart Failure. https://doi.org/10.1093/eurjhf/hfq006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.