Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 593

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

2010 Focused Update of ESC Guidelines on device therapy in heart failure

Open access
Authors/Task Force Members, Dickstein, Kenneth, Vardas, Panos E., Auricchio, Angelo, Daubert, Jean-Claude, Linde, Cecilia, McMurray, John, Ponikowski, Piotr, Priori, Silvia Giuliana, Sutton, Richard, van Veldhuisen, Dirk J., ESC Committee for Practice Guidelines (CPG), Vahanian, Alec, Auricchio, Angelo, Bax, Jeroen, Ceconi, Claudio, Dean, Veronica, Filippatos, Gerasimos, Funck-Brentano, Christian, Hobbs, Richard, Kearney, Peter, McDonagh, Theresa, Popescu, Bogdan A., Reiner, Zeljko, Sechtem, Udo, Sirnes, Per Anton, Tendera, Michal, Vardas, Panos, Widimsky, Petr, Document Reviewers, Tendera, Michal, Anker, Stefan D., Blanc, Jean-Jacques, Gasparini, Maurizio, Hoes, Arno W., Israel, Carsten W., Kalarus, Zbigniew, Merkely, Bela, Swedberg, Karl, Camm, A. John·2010·EP Europace

Abstract

atrial fibrillation atrio-ventricular Committee for Practice Guidelines cardiac resynchronization therapy CRT with pacemaker function CRT with defibrillator function cardiac transplantation cardiovascular European Heart Rhythm Association European Society of Cardiology heart failure Heart Failure Association hospitalization implantable cardioverter defibrillator left bundle branch block left ventricular left ventricular assist device left ventricular end-diastolic diameter left ventricular ejection fraction left ventricular stroke volume index left ventricular end-systolic volume 6 min walk test not applicable National Institutes of Health not significant New York Heart Association optimal medical therapy peak oxygen consumption quality of life right bundle branch block randomized clinical trial sinus rhythm ventilation/carbon dioxide ratio The Committee for Practice Guidelines (CPG) of the European Society of Cardiology recognizes that new evidence from clinical research trials may impact on current recommendations. The current heart failure (HF) guidelines1 were published in 2008 and the cardiac pacing guidelines in 2007.2 In order to keep these guidelines up to date, it would be appropriate to modify the recommendations and levels of evidence according to the most recent clinical trial evidence. This Focused Update on the use of devices in heart failure 2010 is the first publication of its kind from the CPG. Practice Guideline recommendations should represent evidence-based medicine. Traditionally, these recommendations are based on the outcomes in the cohort of patients described by the inclusion criteria in the protocols of randomized clinical trials (RCTs). More recently, based on the fact that the characteristics of the patients actually included in a trial may differ substantially from the eligibility criteria, Guideline Task Force members frequently favour restricting the applicability of these recommendations to the clinical profile and outcomes of the enrolled cohort, representing a more accurate interpretation of the evidence provided by a trial's result. In contrast to previous guidelines, this focused update considers the characteristics of the patients included in the trials and contains several examples. In MADIT-CRT, although the protocol permitted inclusion of patients in both New York Heart Association (NYHA) I and II function class, only 15% of the patients included in this trial were classified as NYHA I, many of whom had been previously symptomatic. Similarly, although the inclusion criteria permitted randomization of patients with a QRS width of ≥130 m, the favourable effect on the primary endpoint was limited to patients with a QRS width of ≥150 ms, a prospective, pre-specified cut-off. The text accompanying these recommendations explains and justifies the decisions to diverge from a traditional recommendation based strictly on the protocol inclusion criteria. The Task Force hopes that the users of the Guidelines will appreciate that this adjustment provides a more realistic application of the trial evidence to daily clinical practice. The management of patients with HF represents a substantial economic burden and hospitalization is responsible for >50% of this expense.3 The initial expense of device implantation must be weighed against measures of short- and long-term efficacy with regard to survival, morbidity, and quality of life.4 The effective use of limited health care resources necessitates identification of the characteristics of the patient population most likely to benefit from cardiac resynchronization therapy (CRT) and treatment strategy should target these patients for device implantation. The clinical effects of long-term CRT have been evaluated in a large number of randomized multi-centre trials with crossover or parallel treatment assignment,5–11 using CRT pacemakers (CRT-P) or CRT-implantable cardioverter defibrillator (ICD) devices (CRT-D). Practice with regard to the choice of the CRT device varies widely between countries.4 Meta-analyses were also published,12–15 suggesting that the most efficacious option in patients with HF and low left ventricular ejection fraction (LVEF) would be a CRT-D. The usual study enrolment criteria were: NYHA function class III or IV despite optimal pharmacological treatment, LVEF ≤35%, sinus rhythm (SR), left ventricular (LV) dilatation but with varying definitions, and QRS duration ≥120/ ≥ 130 ms. All RCTs have confirmed a significant alleviation of symptoms and increase in exercise capacity conferred by CRT. On average, NYHA function class decreased by 0.5–0.8 points, the 6 min walk distance increased by 20%, and peak oxygen consumption increased by 10–15%. The functional benefits and quality of life improvements were sustained.11,16,17 In the COMPANION trial, CRT with or without an ICD, lowered the combined endpoint of all-cause mortality and rehospitalization for HF by 35–40%, mainly driven by the 76% lower rate of hospitalization

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euq392

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

See all 593

Metadata

Authors
Authors/Task Force Members, Dickstein, K., Vardas, P. E., Auricchio, A., Daubert, J.-C., Linde, C., McMurray, J., Ponikowski, P., Priori, S. G., Sutton, R., van Veldhuisen, D. J., ESC Committee for Practice Guidelines (CPG), Vahanian, A., Auricchio, A., Bax, J., Ceconi, C., Dean, V., Filippatos, G., Funck-Brentano, C., Hobbs, R., Kearney, P., McDonagh, T., Popescu, B. A., Reiner, Z., Sechtem, U., Sirnes, P. A., Tendera, M., Vardas, P., Widimsky, P., Reviewers, D., Tendera, M., Anker, S. D., Blanc, J.-J., Gasparini, M., Hoes, A. W., Israel, C. W., Kalarus, Z., Merkely, B., Swedberg, K., & Camm, A. J.
Venue
EP Europace
Published
2010-11-01
Volume
12
Issue
11
Pages
1526-1536
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2414569055
Cited by
593
References
56
FWCI
69.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 2010 Focused Update of ESC Guidelines on device therapy in heart failure. https://app.cochat.ai/papers/10.1093/europace/euq392
The paper
Authors/Task Force Members, Dickstein, K., Vardas, P. E., Auricchio, A., Daubert, J.-C., Linde, C., McMurray, J., Ponikowski, P., Priori, S. G., Sutton, R., van Veldhuisen, D. J., ESC Committee for Practice Guidelines (CPG), Vahanian, A., Auricchio, A., Bax, J., Ceconi, C., Dean, V., Filippatos, G., Funck-Brentano, C., . . . Camm, A. J. (2010). 2010 Focused Update of ESC Guidelines on device therapy in heart failure. EP Europace. https://doi.org/10.1093/europace/euq392

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.