Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Prognostic Electrocardiographic Parameters in Patients with Suspected Myocarditis

Ukena, Christian, Mahfoud, Felix, Kindermann, Ingrid, Kandolf, Reinhard, Kindermann, Michael, Böhm, Michael · 2011 · European Journal of Heart Failure

Abstract

Aims: The objective of this study was to investigate the prognostic value of electrocardiographic (ECG) parameters for outcome in patients acutely admitted with myocarditis without previous heart failure who underwent endomyocardial biopsy. Methods and results: Between 1995 and 2009, 186 consecutive patients (age: 43.4 ± 13.9 years) acutely admitted with clinically suspected myocarditis were enrolled and followed up for a mean of 55.1 ± 105.1 months. Electrocardiograms recorded before myocardial biopsy were analysed for rhythm, conduction times, signs of hypertrophy, and repolarization abnormalities. The primary endpoint was time to cardiac death or heart transplantation. The mean QRS duration was 90.3 ± 24.3 ms; 158 patients had a normal QRS duration (<120 ms) and 21 patients had a prolonged QRS duration (≥120 ms). During follow-up, 15.8% of patients with a normal QRS duration reached the primary endpoint compared with 42.8% of patients with a prolonged baseline QRS duration [hazard ratio (HR) 3.43; 95% confidence interval (CI) 1.78–6.01; P < 0.001]. The increased risk predicted by a prolonged QRS duration was robust after adjusting for covariates (HR 2.83; CI 1.07–7.49; P = 0.012). A QTc prolongation ≥440 ms (P = 0.011), an abnormal QRS axis (P = 0.012), and premature ventricular beats (P = 0.018) were significant monovariate predictors but did not prove to be independent predictors for survival in multivariate analysis. Q-waves and repolarization abnormalities were neither associated with the primary endpoint nor with immunohistological signs of inflammation. Other ECG parameters were not significantly related to outcome. Conclusion: A prolonged QRS duration is an independent predictor for cardiac death or heart transplantation in patients with suspected myocarditis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurjhf/hfq229

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
Ukena, C., Mahfoud, F., Kindermann, I., Kandolf, R., Kindermann, M., & Böhm, M.
Venue
European Journal of Heart Failure
Published
2011-04-01
Volume
13
Issue
4
Pages
398-405
ISSN
  • 1388-9842 (ISSN-L)
  • 1879-0844
OpenAlex
W2148476678
Cited by
212
References
1
FWCI
6.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognostic Electrocardiographic Parameters in Patients with Suspected Myocarditis. https://app.cochat.ai/papers/10.1093/eurjhf/hfq229
The paper
Ukena, C., Mahfoud, F., Kindermann, I., Kandolf, R., Kindermann, M., & Böhm, M. (2011). Prognostic Electrocardiographic Parameters in Patients with Suspected Myocarditis. European Journal of Heart Failure. https://doi.org/10.1093/eurjhf/hfq229

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.