CoChat

Preventing Ventricular Dysfunction in Pacemaker Patients without Advanced Heart Failure: Results from a Multicentre International Randomized Trial (PREVENT-HF)

Open access
Stockburger, Martin, Gómez-Doblas, Juan José, Lamas, Gervasio, Alzueta, Javier, Fernández-Lozano, Ignacio, Cobo, Erik, Wiegand, Uwe, de la Concha, Joaquín Fernández, Navarro, Xavier, Navarro-López, Francisco, de Teresa, Eduardo · 2011 · European Journal of Heart Failure
Cited by 134

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Aims: Previous experimental and clinical studies have consistently suggested that right ventricular (RV) apical pacing has important adverse effects. Ventricular pacing (VP), however, is required, and cannot be reduced in many patients with atrioventricular (AV) block. The PREVENT-HF study was an international randomized trial that explored differences in left ventricular (LV) remodelling during RV apical vs. biventricular (BIV) pacing in patients with AV block. Methods and Results: Patients with an expected VP prevalence ≥80% were assigned to RV apical or BIV pacing. The primary endpoint was the change in LV end-diastolic volume (EDV) >12 months. Secondary endpoints were LV end-systolic volume (ESV), LV ejection fraction (EF), mitral regurgitation (MR), and a combination of heart failure (HF) events and cardiovascular hospitalizations. Overall, 108 patients were randomized (RV: 58; BIV: 50). Intention to treat and on-treatment analyses revealed no significant differences in any of the outcomes. Analysis of covariance (ANCOVA) difference for treatment according to randomization (in mL): LVEDV −3.92 (−18.71 to 10.85), P= 0.6; LVESV −1.38 (−12.07 to 9.31), P= 0.80; LVEF 2.47 (−3.00 to 7.94), P= 0.37. Analysis of covariance difference for the on-treatment analysis: LVEDV −4.90 (−20.02 to 10.22, PP= 0.52; LVESV −6.45 (−17.28 to 4.38), P= 0.24, LVEF 2.18 (−3.37 to 7.73), P= 0.44. Furthermore, secondary endpoints did not differ significantly. Conclusion: This study did not demonstrate significant LV volume differences >12 months between RV apical and BIV pacing for AV block. Thus, BIV pacing cannot be recommended as a routine treatment for AV block in these patients. However, the results encourage and inform the design of subsequent larger trials with higher power for detecting small volume changes. ClinicalTrials.gov Identifier: NCT00170326.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurjhf/hfr041

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 134

Metadata

Authors
Stockburger, M., Gómez-Doblas, J. J., Lamas, G., Alzueta, J., Fernández-Lozano, I., Cobo, E., Wiegand, U., de la Concha, J. F., Navarro, X., Navarro-López, F., & de Teresa, E.
Venue
European Journal of Heart Failure
Published
2011-06-01
Volume
13
Issue
6
Pages
633-641
ISSN
  • 1388-9842 (ISSN-L)
  • 1879-0844
OpenAlex
W2121339827
Cited by
134
References
4
FWCI
6.56
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preventing Ventricular Dysfunction in Pacemaker Patients without Advanced Heart Failure: Results from a Multicentre International Randomized Trial (PREVENT-HF). https://app.cochat.ai/papers/10.1093/eurjhf/hfr041
The paper
Stockburger, M., Gómez-Doblas, J. J., Lamas, G., Alzueta, J., Fernández-Lozano, I., Cobo, E., Wiegand, U., de la Concha, J. F., Navarro, X., Navarro-López, F., & de Teresa, E. (2011). Preventing Ventricular Dysfunction in Pacemaker Patients without Advanced Heart Failure: Results from a Multicentre International Randomized Trial (PREVENT-HF). European Journal of Heart Failure. https://doi.org/10.1093/eurjhf/hfr041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.