Vagus Nerve Stimulation Improves Left Ventricular Function in a Canine Model of Chronic Heart Failure
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Aims: Autonomic dysfunction is a feature of chronic heart failure (HF). This study tested the hypothesis that chronic open-loop electrical vagus nerve stimulation (VNS) improves LV structure and function in canines with chronic HF. Methods and results: Twenty-six canines with HF (EF ∼35%) produced by intracoronary microembolizations were implanted with a bipolar cuff electrode around the right cervical vagus nerve and connected to an implantable pulse generator. The canines were enrolled in Control (n = 7) vs. VNS therapy (n = 7) or a crossover study, with crossovers occurring at 3 months (C × VNS, n = 6; VNS × C, n = 6). After 6 months of VNS, LVEF and LV end-systolic volume (ESV) were significantly improved compared with Control (ΔEF Control −4.6 ± 0.9% vs. VNS 6.0 ± 1.6%, P < 0.001) and (ΔESV Control 8.3 ± 1.8 mL vs. VNS −3.0 ± 2.3 mL, P = 0.002. Plasma and tissue biomarkers were also improved. In the crossover study, VNS also resulted in a significant improvement in EF and ESV compared with Control (ΔEF Control −2.3 ± 0.65% vs. VNS 6.7 ± 1.1 mL, P < 0.001 and ΔESV Control 3.2 ± 1.2 mL vs. VNS −4.0 ± 0.9 mL, P < 0.001). Initiation of therapy in the Control group at 3 months resulted in a significant improvement in EF (Control −4.7 ± 1.4% vs. VNS 3.7 ± 0.74%, P < 0.001) and ESV (Control 1.5 ± 1.2 mL vs. NS −5.5 ± 1.6 mL, P = 0.003) by 6 months. Conclusions: In canines with HF, long-term, open-looped low levels of VNS therapy improves LV systolic function, prevents progressive LV enlargement, and improves biomarkers of HF when compared with control animals that did not receive therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chronic vagus nerve stimulation: A new and promising therapeutic approach for chronic heart failure
De Ferrari, G. M., Crijns, H. J. G. M., Borggrefe, M., Milasinovic, G., Smid, J., Zabel, M., Gavazzi, A., Sanzo, A., Dennert, R., Kuschyk, J., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq391 · Cited by 523 · cited 4×
“Methods This study was approved by the Henry Ford Health System Institutional Animal Care and Use Committee and conformed to the ‘Position of the American Heart Association on Research Animal Use’.12 Experimental heart failure model The canine model of chronic post-ischaemic heart failure used in this study was previo…”
BackgroundMethodInfluentialClosed-loop control of the heart rate by electrical stimulation of the vagus nerve
Tosato, M., Yoshida, K., Toft, E., Nekrasas, V., & Struijk, J. J. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0037-1 · Cited by 78 · cited 2×
“report that B-fibres have a cardiac slowing effect but the magnitude of the slowing is significantly lower than that achieved when C-fibres are also stimulated.(21) In the present study, stimulation amplitudes were well below the amplitudes previously reported to evoke bradycardia.”
MethodResult
Cited by
Zannad, F., De Ferrari, G. M., Tuinenburg, A. E., Wright, D., Brugada, J., Butter, C., Klein, H., Stolen, C., Meyer, S., Stein, K. M., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu345 · Cited by 380
Self-citationPremchand, R. K., Sharma, K., Mittal, S., Monteiro, R., Dixit, S., Libbus, I., DiCarlo, L. A., Ardell, J. L., Rector, T. S., Amurthur, B., et al. (2014) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2014.08.009 · Cited by 377
Clinical neurocardiology defining the value of neuroscience-based cardiovascular therapeutics
Shivkumar, K., Ajijola, O. A., Anand, I., Armour, J. A., Chen, P., Esler, M., De Ferrari, G. M., Fishbein, M. C., Goldberger, J. J., Harper, R. M., et al. (2016) · The Journal of Physiology · doi:10.1113/jp271870 · Cited by 308
Machhada, A., Hosford, P. S., Dyson, A., Ackland, G. L., Mastitskaya, S., & Gourine, A. V. (2020) · JACC: Basic to Translational Science · doi:10.1016/j.jacbts.2020.06.002 · Cited by 88
Metadata
- Authors
- Hamann, J. J., Ruble, S. B., Stolen, C., Wang, M., Gupta, R. C., Rastogi, S., & Sabbah, H. N.
- Venue
- European Journal of Heart Failure
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-12-01
- Volume
- 15
- Issue
- 12
- Pages
- 1319-1326
- ISSN
- 1388-9842 (ISSN-L)
- 1879-0844
- OpenAlex
- W2026520142
- Cited by
- 111
- References
- 2
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vagus Nerve Stimulation Improves Left Ventricular Function in a Canine Model of Chronic Heart Failure. https://app.cochat.ai/papers/10.1093/eurjhf/hft118
- The paper
- Hamann, J. J., Ruble, S. B., Stolen, C., Wang, M., Gupta, R. C., Rastogi, S., & Sabbah, H. N. (2013). Vagus Nerve Stimulation Improves Left Ventricular Function in a Canine Model of Chronic Heart Failure. European Journal of Heart Failure. https://doi.org/10.1093/eurjhf/hft118
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.