Type-D personality but not implantable cardioverter-defibrillator indication is associated with impaired health-related quality of life 3 months post-implantation
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
AIMS: Little is known about the impact of ICD indication (primary vs. secondary) on health-related quality of life (HRQL). Indication may also interact with psychological factors, such as personality. Using a prospective design, we examined whether ICD indication and type-D personality (i.e. experiencing increased negative emotions paired with emotional non-expression) serve as modulators of HRQL at baseline and 3 months post-implantation. METHODS AND RESULTS: Consecutively implanted ICD patients (n = 154) completed the Type-D Scale (DS14) at baseline and the Short-Form Health Survey 36 (SF-36) at baseline and 3 months. Of all patients, 82 (53%) received an ICD due to prophylactic reasons; the prevalence of type-D was 23%. Indication had no influence on HRQL (P = 0.75). Further stratification by personality showed a main effect for type-D personality (P < 0.001), with type-D patients generally experiencing poorer HRQL; there was no main effect for indication (P = 0.45) nor was the interaction effect indication by type-D significant (P = 0.22). There was a significant improvement in HRQL over time (P = 0.001). Type-D remained an independent predictor of impaired HRQL, adjusting for clinical factors and shocks during follow-up (P < 0.001). However, in adjusted analysis there was no longer a significant change in HRQL over time (P = 0.099). CONCLUSION: Type-D personality but not ICD indication was associated with impaired HRQL at the time of implantation and at 3 months. In the quest for enhancing risk stratification in clinical practice, personality factors, such as type-D, should not be ignored, as both type-D and poor HRQL have been associated with increased risk of mortality in cardiac patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Aaronson, N. K., Muller, M., Cohen, P. D. A., Essink-Bot, M.-L., Fekkes, M., Sanderman, R., Sprangers, M. A. G., te Velde, A., & Verrips, E. (1998) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(98)00097-3 · Cited by 2,276
Schron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
Kubzansky, L. D., Sparrow, D., Vokonas, P., & Kawachi, I. (2001) · Psychosomatic Medicine · doi:10.1097/00006842-200111000-00009 · Cited by 400
Quality of life in the Canadian Implantable Defibrillator Study (CIDS)
Irvine, J., Dorian, P., Baker, B., O'Brien, B. J., Roberts, R., Gent, M., Newman, D., & Connolly, S. J. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124049 · Cited by 368
Pedersen, S. S., van Domburg, R. T., Theuns, D. A. M. J., Jordaens, L., & Erdman, R. A. M. (2004) · Psychosomatic Medicine · doi:10.1097/01.psy.0000132874.52202.21 · Cited by 207
Self-citationPredictors of Quality of Life in Patients With Implantable Cardioverter Defibrillators
Sears, S. F., Lewis, T. S., Kuhl, E. A., & Conti, J. B. (2005) · Psychosomatics · doi:10.1176/appi.psy.46.5.451 · Cited by 128
Prevention of implantable defibrillator shocks by cognitive behavioral therapy: A pilot trial
Chevalier, P., Cottraux, J., Mollard, E., Sai, N., Brun, S., Burri, H., Restier, L., & Adeleine, P. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.10.007 · Cited by 81
Cited by
Dunbar, S. B., Dougherty, C. M., Sears, S. F., Carroll, D. L., Goldstein, N. E., Mark, D. B., McDaniel, G., Pressler, S. J., Schron, E., Wang, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31825d59fd · Cited by 221
Does personality affect health-related quality of life?A systematic review
Huang, I.-C., Lee, J. L., Ketheeswaran, P., Jones, C. M., Revicki, D. A., & Wu, A. W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0173806 · Cited by 159
Risk of Ventricular Arrhythmia After Implantable Defibrillator Treatment in Anxious Type D Patients
van den Broek, K. C., Nyklíček, I., van der Voort, P. H., Alings, M., Meijer, A., & Denollet, J. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.043 · Cited by 110
Psychological Adjustment in ICD Patients Living With Advisory Fidelis Leads
KEREN, A., SEARS, S. F., NERY, P., SHAW, J., GREEN, M. S., LEMERY, R., GOLLOB, M. H., AMYOTTE, B., & BIRNIE, D. H. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01867.x · Cited by 37
LANG, S., BECKER, R., WILKE, S., HARTMANN, M., HERZOG, W., & LÖWE, B. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12276 · Cited by 36
Metadata
- Authors
- Pedersen, S. S., Theuns, D. A., Muskens-Heemskerk, A., Erdman, R. A., & Jordaens, L.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-04-13
- Volume
- 9
- Issue
- 8
- Pages
- 675-680
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2087636140
- Cited by
- 80
- References
- 9
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Type-D personality but not implantable cardioverter-defibrillator indication is associated with impaired health-related quality of life 3 months post-implantation. https://app.cochat.ai/papers/10.1093/europace/eum041
- The paper
- Pedersen, S. S., Theuns, D. A., Muskens-Heemskerk, A., Erdman, R. A., & Jordaens, L. (2007). Type-D personality but not implantable cardioverter-defibrillator indication is associated with impaired health-related quality of life 3 months post-implantation. EP Europace. https://doi.org/10.1093/europace/eum041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.