CoChat

Direct His bundle pacing preserves coronary perfusion compared with right ventricular apical pacing: a prospective, cross-over mid-term study

Open access
Zanon, F., Bacchiega, E., Rampin, L., Aggio, S., Baracca, E., Pastore, G., Marotta, T., Corbucci, G., Roncon, L., Rubello, D., Prinzen, F. W. · 2008 · Europace
Cited by 114

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

AIMS: The His bundle is regarded as the most physiological site for ventricular pacing, in that it avoids the adverse effects of right ventricular apical pacing (RVAP). However, very few studies have compared the effects of direct His bundle pacing (DHBP) and RVAP. The aim of our study was the intra-patient comparison of myocardial perfusion corresponding to these two different pacing techniques, as perfusion expresses local workload and is related to long-term outcome. METHODS AND RESULTS: Twelve consecutive patients with standard pacemaker indication (9 male, 74 +/- 9 years) entered the study. Pacing leads were implanted in the right ventricular apex and directly in the His bundle, and were connected to different ports of the pacemaker. All patients first underwent 3 months of DHBP, followed by 3 months of RVAP. At the end of each 3-month period, myocardial perfusion was measured at rest using scintigraphy with Tc99m-SestaMIBI. The average values of perfusion were evaluated on a 20-segment basis. All patients also underwent clinical evaluation, echocardiography, and tissue Doppler imaging (TDI), to measure dyssynchrony, and a blood sample was taken for brain natriuretic peptide (BNP) assay. The perfusion score during DHBP pacing was significantly better than during RVAP (0.44 +/- 0.5 vs. 0.71 +/- 0.53, respectively; P = 0.011). None of the patients showed lower perfusion during DHBP than during RVAP. We found no significant difference in NYHA class, ventricular volumes, ejection fraction, or plasmatic BNP between DHBP and RVAP. However, mitral regurgitation (0.26 +/- 0.21 vs. 0.37 +/- 0.25; P < 0.001) and dyssynchrony (13.75 +/- 4.28 vs. 22.02 +/- 8.44; P = 0.008) were significantly less during DHBP than during RVAP. CONCLUSION: Direct His bundle pacing is superior to RVAP in preserving the physiologic distribution of myocardial blood flow and reducing mitral regurgitation and left ventricular dyssynchrony.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eun089

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 114

Metadata

Authors
Zanon, F., Bacchiega, E., Rampin, L., Aggio, S., Baracca, E., Pastore, G., Marotta, T., Corbucci, G., Roncon, L., Rubello, D., & Prinzen, F. W.
Venue
Europace
Published
2008-04-07
Volume
10
Issue
5
Pages
580-587
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W1967719122
Cited by
114
References
4
FWCI
5.28
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct His bundle pacing preserves coronary perfusion compared with right ventricular apical pacing: a prospective, cross-over mid-term study. https://app.cochat.ai/papers/10.1093/europace/eun089
The paper
Zanon, F., Bacchiega, E., Rampin, L., Aggio, S., Baracca, E., Pastore, G., Marotta, T., Corbucci, G., Roncon, L., Rubello, D., & Prinzen, F. W. (2008). Direct His bundle pacing preserves coronary perfusion compared with right ventricular apical pacing: a prospective, cross-over mid-term study. Europace. https://doi.org/10.1093/europace/eun089

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.