CoChat

Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure

Spencker, S., Coban, N., Koch, L., Schirdewan, A., Muller, D. · 2008 · Europace
Cited by 129

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

AIMS: Lead dysfunctions in implantable cardioverter-defibrillator (ICD) patients can lead to inappropriate shocks or even complete loss of function of the device. Home monitoring (HM) systems are capable of daily data transmissions regarding the device and the lead integrity as well as information concerning anti-arrhythmic therapies. We therefore analysed the data from the Biotronik HM system whether it enables physicians to react quickly on serious ICD malfunctions and to avoid inappropriate shocks. METHODS AND RESULTS: Fifty-four patients who had to undergo resurgery due to malfunctions of the ICD lead were included. Eleven of them were on HM interrogating the device every night at 3 am. If any adverse event was detected, a fax alert was sent to the clinic and the patients were asked for in-hospital ICD interrogation. The rate of inappropriate shocks and symptomatic pacemaker inhibition due to oversensing was compared with the 43 patients without remote surveillance. HM sent alert messages in 91% of all incidents. All lead failures became obvious because of oversensing of high frequency artefacts. Only in 18%, changes in the pacing impedance were noticed, in all cases preceded by oversensing. Eighty per cent of the patients were asymptomatic at the first onset of oversensing. Only one patient suffered an inappropriate shock as first manifestation of lead failure. Compared with the patients without HM, inappropriate shocks occurred in 27.3% in the HM group vs. 46.5% (P = n.s.). This trend gains statistical significance, if the compound endpoint of symptomatic lead failure consisting of inappropriate shocks and symptomatic pacemaker inhibition due to oversensing is focused: 27.3% event in the HM group vs. 53.4% in the group without HM (P = 0.04). Event messages were despatched in a mean of 54 days after the last ICD interrogation and 56 days before next scheduled visit. Thus, 56 days of reaction time are gained to avoid adverse events. CONCLUSION: In 91% of all lead-related ICD complications, the diagnosis could be established correctly by an alert of the HM system. Mostly, the first incident sent was oversensing of artefacts, falsely detected as ventricular fibrillation-the VF zone. The automatic HM surveillance system enables physicians to detect severe lead problems early and to react quickly; thus, it might have a potential to avoid inappropriate shocks due to lead failure and T-wave oversensing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eun350

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Spencker, S., Coban, N., Koch, L., Schirdewan, A., & Muller, D.
Venue
Europace
Published
2008-12-26
Volume
11
Issue
4
Pages
483-488
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2136068253
Cited by
129
References
1
FWCI
7.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.