Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AIMS: Lead dysfunctions in implantable cardioverter-defibrillator (ICD) patients can lead to inappropriate shocks or even complete loss of function of the device. Home monitoring (HM) systems are capable of daily data transmissions regarding the device and the lead integrity as well as information concerning anti-arrhythmic therapies. We therefore analysed the data from the Biotronik HM system whether it enables physicians to react quickly on serious ICD malfunctions and to avoid inappropriate shocks. METHODS AND RESULTS: Fifty-four patients who had to undergo resurgery due to malfunctions of the ICD lead were included. Eleven of them were on HM interrogating the device every night at 3 am. If any adverse event was detected, a fax alert was sent to the clinic and the patients were asked for in-hospital ICD interrogation. The rate of inappropriate shocks and symptomatic pacemaker inhibition due to oversensing was compared with the 43 patients without remote surveillance. HM sent alert messages in 91% of all incidents. All lead failures became obvious because of oversensing of high frequency artefacts. Only in 18%, changes in the pacing impedance were noticed, in all cases preceded by oversensing. Eighty per cent of the patients were asymptomatic at the first onset of oversensing. Only one patient suffered an inappropriate shock as first manifestation of lead failure. Compared with the patients without HM, inappropriate shocks occurred in 27.3% in the HM group vs. 46.5% (P = n.s.). This trend gains statistical significance, if the compound endpoint of symptomatic lead failure consisting of inappropriate shocks and symptomatic pacemaker inhibition due to oversensing is focused: 27.3% event in the HM group vs. 53.4% in the group without HM (P = 0.04). Event messages were despatched in a mean of 54 days after the last ICD interrogation and 56 days before next scheduled visit. Thus, 56 days of reaction time are gained to avoid adverse events. CONCLUSION: In 91% of all lead-related ICD complications, the diagnosis could be established correctly by an alert of the HM system. Mostly, the first incident sent was oversensing of artefacts, falsely detected as ventricular fibrillation-the VF zone. The automatic HM surveillance system enables physicians to detect severe lead problems early and to react quickly; thus, it might have a potential to avoid inappropriate shocks due to lead failure and T-wave oversensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Cited by
Hindricks, G., Taborsky, M., Glikson, M., Heinrich, U., Schumacher, B., Katz, A., Brachmann, J., Lewalter, T., Goette, A., Block, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61176-4 · Cited by 740
Slotwiner, D., Varma, N., Akar, J. G., Annas, G., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 532
Guedon-Moreau, L., Lacroix, D., Sadoul, N., Clementy, J., Kouakam, C., Hermida, J.-S., Aliot, E., Boursier, M., Bizeau, O., Kacet, S., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs425 · Cited by 312
Telemedicine and telecare for older patients—A systematic review
van den Berg, N., Schumann, M., Kraft, K., & Hoffmann, W. (2012) · Maturitas · doi:10.1016/j.maturitas.2012.06.010 · Cited by 251
Telemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102
“reaction time was advanced by almost 2 months to avoid adverse events.(30)”
BackgroundDubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
Remote monitoring of implantable devices: should we continue to ignore it?
Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.09.033 · Cited by 28
Monitoring capabilities of cardiac rhythm management devices
Andrikopoulos, G., Tzeis, S., Theodorakis, G., & Vardas, P. (2010) · Europace · doi:10.1093/europace/eup317 · Cited by 5
Metadata
- Authors
- Spencker, S., Coban, N., Koch, L., Schirdewan, A., & Muller, D.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-12-26
- Volume
- 11
- Issue
- 4
- Pages
- 483-488
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2136068253
- Cited by
- 129
- References
- 1
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.