The DOI matches its Crossref record.
A single-centre experience of over one thousand lead extractions
Open accessAbstract
AIMS: The aim of the study was to present a single-centre experience of pacemaker and implantable cardioverter defibrillator (ICD) lead extraction using different methods, mainly laser-assisted extraction. METHODS AND RESULTS: Data from 1032 leads and 647 procedures were gathered. A step-by-step approach using different techniques while performing an ongoing risk-benefit analysis was used. The most common indications were local infection, systemic infection, non-functional lead, elective lead replacement, and J-wire fracture. Mean implantation time for all leads was 69 months and for laser-extracted leads 91 months. Laser technique was used to extract 60% of the leads, 29% were manually extracted, 6% extracted with mechanical tools, 4% were surgically removed, and 0.6% extracted by a femoral approach. Failure rate was 0.7%, and major complication rate was 0.9%. No extraction-related mortality occurred. Median time for laser extraction was 2 min. Long implantation time was not a risk factor for failure or for complication. CONCLUSION: Pacing and ICD leads can safely, successfully, and effectively be extracted. Leads can often be extracted by a superior transvenous approach; however, open-chest and femoral extractions are still required. Laser-assisted lead extraction proved to be a useful technique to extract leads that could not be removed by manual traction. The results indicate that the paradigm of abandoning redundant leads, instead of removing them, may have to be reconsidered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maytin, M., Love, C. J., Fischer, A., Carrillo, R. G., Garisto, J. D., Bongiorni, M. G., Segreti, L., John, R. M., Michaud, G. F., Albert, C. M., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.03.058 · Cited by 89
Guidelines for Managing Pacemaker and Implantable Defibrillator Advisories
Kramer, D. B., & Maisel, W. H. (2011) · Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy · doi:10.1016/b978-1-4377-1616-0.00034-5 · Cited by 8
Metadata
- Authors
- Kennergren, C., Bjurman, C., Wiklund, R., & Gabel, J.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-03-27
- Volume
- 11
- Issue
- 5
- Pages
- 612-617
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W1975500774
- Cited by
- 205
- References
- 0
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A single-centre experience of over one thousand lead extractions. https://app.cochat.ai/papers/10.1093/europace/eup054
- The paper
- Kennergren, C., Bjurman, C., Wiklund, R., & Gabel, J. (2009). A single-centre experience of over one thousand lead extractions. Europace. https://doi.org/10.1093/europace/eup054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.