Cited by 17Atrial Fibrillation Management and OutcomesCardiac Arrhythmias and TreatmentsCardiac pacing and defibrillation studies

Dofetilide is safe and effective in preventing atrial fibrillation recurrences in patients accepted for catheter ablation

Shamiss, Yana, Khaykin, Yaariv, Oosthuizen, Richard, Tunney, Denise, Sarak, Bradley, Beardsall, Marianne, Seabrook, Catherine, Frost, Linda +3 more·2009·EP Europace

Abstract

AIMS: The aim of this study was to assess the safety and efficacy of dofetilide among patients refractory to other anti-arrhythmic drugs (AADs) and accepted for atrial fibrillation (AF) ablation. METHODS AND RESULTS: One hundred and twenty-seven of 454 patients (69% male, 58% paroxysmal, age 60 +/- 10 years, AF duration 8 +/- 7 years) scheduled for AF ablation between February 2004 and May 2008 were treated with dofetilide. Patients had failed 1.9 +/- 1.1 AADs. Anti-arrhythmic drugs were stopped five half-lives before ablation and 3 months for amiodarone. Patients were followed for 15 +/- 7 months with routine and symptom-driven monitoring. Success was defined as no further AF and partial success as a 50% reduction in frequency/duration of AF episodes. Thirty-six patients started dofetilide 158 +/- 167 days before ablation: 9 had no improvement, 16 experienced partial success, 8 had no further AF, and 2 improved enough to forgo ablation. Seventy-one patients started dofetilide immediately following ablation, of which 14 had no improvement, 22 experienced partial success, and 32 had no further AF. Twenty patients started dofetilide 119 +/- 153 days post-ablation, of which four had no improvement, seven experienced partial success, and nine had no further AF. Six patients discontinued dofetilide during initiation for QT prolongation. CONCLUSION: Dofetilide appears safe and effective in preventing AF in patients refractory to other AADs undergoing catheter ablation.

Integrity signals

Registry

Crossref · 10.1093/europace/eup293

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Shamiss, Y., Khaykin, Y., Oosthuizen, R., Tunney, D., Sarak, B., Beardsall, M., Seabrook, C., Frost, L., Wulffhart, Z., Tsang, B., & Verma, A.
Affiliations
Southlake Regional Health Center (CA)
Corresponding author
Khaykin, Yaariv
Venue
EP Europace
Published
2009-10-08
Volume
11
Issue
11
Pages
1448-1455
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2065282863
Cited by
17
References
18
Citations by year
2025: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 3 · 2015: 1 · 2014: 2 · 2013: 1
FWCI
1.08
Type
journal article
Language
en
Open access
closed
Locations
  • EP Europace (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
dofetilide, atrial fibrillation, catheter ablation, antiarrhythmic drugs, refractory atrial fibrillation, atrial fibrillation recurrence prevention, QT prolongation, drug safety, drug efficacy
MeSH terms
Atrial Fibrillation, Female, Humans, Male, Middle Aged, Phenethylamines, Premedication, Sulfonamides, Treatment Outcome, Catheter Ablation, Secondary Prevention

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review