Left ventricular systolic dysfunction by itself does not influence outcome of atrial fibrillation ablation
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
AIMS: The objective of the study was to analyse the influence of left ventricular (LV) ejection fraction (EF) on the outcomes of atrial fibrillation (AF) ablation after a first procedure. Pre-procedural predictors of recurrences after AF ablation can be useful for patient information and selection of candidates. The independent influence of LV systolic dysfunction on recurrence rate has not been studied. METHODS AND RESULTS: A case-control study (1:1) was conducted with a total of 72 patients: 36 cases (depressed LVEF) and 36 controls (normal LVEF). Patients were matched by left atrial diameter (LAD), the presence of arterial hypertension, and other variables that might influence the results (age, gender and paroxysmal vs. persistent AF). There were no statistical differences in the variables used to perform the matching. Patients with depressed LVEF had higher LV end diastolic diameter (55.6 +/- 6.2 vs. 52.4 +/- 5.5, P = 0.03), higher LV end systolic diameter (40.3 +/- 6.9 vs. 32.6 +/- 4.3, P < 0.001), lower LVEF (41.4 +/- 8.0 vs. 63.1 +/- 5.5, P < 0.001) and were more likely to have structural heart disease. After a mean follow-up of 16 +/- 13 months, survival analysis for AF recurrences showed no differences between patients with depressed vs. normal LVEF (50.0 vs. 55.6%, log rank = 0.82). Cox regression analysis revealed LAD to be the only variable correlated to recurrence [OR 1.11 (1.01-1.22), P = 0.03]. Analysis at 6 months showed a significant increase in LVEF (43.23 +/- 7.61 to 51.12 +/- 13.53%, P = 0.01) for the case group. CONCLUSION: LV systolic dysfunction by itself is not a predictor of outcome after AF ablation. LAD independently correlates with outcome in patients with low or normal LVEF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Wang, T. J., Larson, M. G., Levy, D., Vasan, R. S., Leip, E. P., Wolf, P. A., D’Agostino, R. B., Murabito, J. M., Kannel, W. B., & Benjamin, E. J. (2003) · Circulation · doi:10.1161/01.cir.0000072767.89944.6e · Cited by 1,970
Rhythm control versus rate control for atrial fibrillation and heart failure
Roy, D., Talajic, M., Nattel, S., Wyse, D. G., Dorian, P., Lee, K. L., Bourassa, M. G., Arnold, J. M. O., Buxton, A. E., Camm, A. J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708789 · Cited by 1,585
Clinical Outcomes After Ablation and Pacing Therapy for Atrial Fibrillation: A Meta-Analysis
Wood, M. A., Brown-Mahoney, C., Kay, G. N., & Ellenbogen, K. A. (2000) · Circulation · doi:10.1161/01.cir.101.10.1138 · Cited by 476
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citation
Metadata
- Authors
- De Potter, T., Berruezo, A., Mont, L., Matiello, M., Tamborero, D., Santibanez, C., Benito, B., Zamorano, N., & Brugada, J.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-10-31
- Volume
- 12
- Issue
- 1
- Pages
- 24-29
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2044065081
- Cited by
- 71
- References
- 4
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Left ventricular systolic dysfunction by itself does not influence outcome of atrial fibrillation ablation. https://app.cochat.ai/papers/10.1093/europace/eup309
- The paper
- De Potter, T., Berruezo, A., Mont, L., Matiello, M., Tamborero, D., Santibanez, C., Benito, B., Zamorano, N., & Brugada, J. (2010). Left ventricular systolic dysfunction by itself does not influence outcome of atrial fibrillation ablation. Europace. https://doi.org/10.1093/europace/eup309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.