Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation
Open accessThe DOI matches its Crossref record.
Abstract
The objective of this study was to identify electrocardiographic (ECG) and further predictors for atrioventricular (AV) block with a need for pacemaker (PM) implantation after transcatheter aortic valve implantation (TAVI). Pre- and post-procedural ECGs of patients with severe aortic stenosis and ongoing TAVI were investigated in a prospective study. From 50 consecutive patients enrolled in the study (mean age 80 +/- 6 years, 46% men), 17 (34%) experienced an AV block with subsequent requirement of a permanent PM [16 of 36 (44.4%) with CoreValve System and 1 of 14 (7.1%) with Edwards Sapiens System]. In patients with right bundle branch block (RBBB), PM implantation had to be performed more frequently [6 of 6 (100%) with CoreValve System and none with Edwards Sapiens System], P = 0.005. An AV block (Mobitz II second degree and third degree) occurred mostly within the first 24 h (range: Days 0-13) after the index procedure. No recovery of AV conduction with a change in PM indication occurred in a mean follow-up time of 13 +/- 6 days. Our data demonstrate that patients with pre-operative RBBB and those receiving CoreValve prosthesis are at a significantly higher risk for PM implantation after TAVI. Therefore, patients with the presence of RBBB before TAVI may be at lower risk for PM implantation using the Edwards Sapiens System.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Siontis, G. C. M., Jüni, P., Pilgrim, T., Stortecky, S., Büllesfeld, L., Meier, B., Wenaweser, P., & Windecker, S. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.033 · Cited by 647
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017) · Circulation · doi:10.1161/circulationaha.117.028352 · Cited by 550
Perioperative Results and Complications in 15,964 Transcatheter Aortic Valve Replacements
Walther, T., Hamm, C. W., Schuler, G., Berkowitsch, A., Kötting, J., Mangner, N., Mudra, H., Beckmann, A., Cremer, J., Welz, A., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.034 · Cited by 402
“whether they are calculated for selected trials or all-comers experiences (11-15).”
BackgroundSelf-citationThe German Aortic Valve Registry (GARY): in-hospital outcome
Hamm, C. W., Mollmann, H., Holzhey, D., Beckmann, A., Veit, C., Figulla, H.-R., Cremer, J., Kuck, K.-H., Lange, R., Zahn, R., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht381 · Cited by 328
Self-citationTranscatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
Left Bundle-Branch Block Induced by Transcatheter Aortic Valve Implantation Increases Risk of Death
Houthuizen, P., Van Garsse, L. A. F. M., Poels, T. T., de Jaegere, P., van der Boon, R. M. A., Swinkels, B. M., ten Berg, J. M., van der Kley, F., Schalij, M. J., Baan, J., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.101055 · Cited by 278
ERKAPIC, D., DE ROSA, S., KELAVA, A., LEHMANN, R., FICHTLSCHERER, S., & HOHNLOSER, S. H. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02211.x · Cited by 230
Self-citationVisualizing anatomical evidences on atrioventricular conduction system for TAVI
Kawashima, T., & Sato, F. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.04.003 · Cited by 161
Metadata
- Authors
- Erkapic, D., Kim, W. K., Weber, M., Mollmann, H., Berkowitsch, A., Zaltsberg, S., Pajitnev, D. J., Rixe, J., Neumann, T., Kuniss, M., Sperzel, J., Hamm, C. W., & Pitschner, H. F.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-03-30
- Volume
- 12
- Issue
- 8
- Pages
- 1188-1190
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W3142643486
- Cited by
- 118
- References
- 0
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.