Course of anxiety and device-related concerns in implantable cardioverter defibrillator patients the first year post implantation

Open access
Pedersen, S. S., Theuns, D. A. M. J., Jordaens, L., Kupper, N. · 2010 · Europace
Cited by 65

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

AIMS: Implantable cardioverter defibrillators (ICDs) are well accepted by most patients, but 25-33% of patients are anxious and report device-related concerns. Previous studies focused on prevalence rates and mean scores, whereas the course of anxiety over time is unknown in individual patients. We examined the trajectory of anxiety in ICD patients during a 1-year period and determinants of these trajectories. METHODS AND RESULTS: Consecutive patients (N = 348) implanted with an ICD completed standardized measures of general anxiety and device-related concerns at five assessment occasions and the Type D Scale at baseline. Type D personality is defined by increased negative emotions and the inhibition of these emotions in social interactions. Seven trajectories were identified for state and trait anxiety and eight for device-related concerns. The course of the trajectories for general anxiety was stable over time, whereas device-related concerns showed more fluctuation, with a decrease in concerns generally spread out during the 1 year. Type D personality and social support were determinants of trajectory membership for general anxiety (all P <or= 0.002), whereas Type D (P = 0.001), social support (P = 0.02), and ICD shock (P < 0.001) determined trajectory membership for device-related concerns. CONCLUSION: The course of general anxiety in ICD patients was stable the first year post implantation, whereas device-related concerns fluctuated more. Type D personality and social support were determinants of trajectory membership for all outcomes, whereas ICD shock was related to device-related concerns only. A simple pre-implant screening may help identify patients at risk for high-distress trajectory membership.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euq154

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 65

Metadata

Authors
Pedersen, S. S., Theuns, D. A. M. J., Jordaens, L., & Kupper, N.
Venue
Europace
Published
2010-05-27
Volume
12
Issue
8
Pages
1119-1126
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2052480919
Cited by
65
References
6
FWCI
5.52
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Course of anxiety and device-related concerns in implantable cardioverter defibrillator patients the first year post implantation. https://app.cochat.ai/papers/10.1093/europace/euq154
The paper
Pedersen, S. S., Theuns, D. A. M. J., Jordaens, L., & Kupper, N. (2010). Course of anxiety and device-related concerns in implantable cardioverter defibrillator patients the first year post implantation. Europace. https://doi.org/10.1093/europace/euq154

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.