Course of anxiety and device-related concerns in implantable cardioverter defibrillator patients the first year post implantation
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
AIMS: Implantable cardioverter defibrillators (ICDs) are well accepted by most patients, but 25-33% of patients are anxious and report device-related concerns. Previous studies focused on prevalence rates and mean scores, whereas the course of anxiety over time is unknown in individual patients. We examined the trajectory of anxiety in ICD patients during a 1-year period and determinants of these trajectories. METHODS AND RESULTS: Consecutive patients (N = 348) implanted with an ICD completed standardized measures of general anxiety and device-related concerns at five assessment occasions and the Type D Scale at baseline. Type D personality is defined by increased negative emotions and the inhibition of these emotions in social interactions. Seven trajectories were identified for state and trait anxiety and eight for device-related concerns. The course of the trajectories for general anxiety was stable over time, whereas device-related concerns showed more fluctuation, with a decrease in concerns generally spread out during the 1 year. Type D personality and social support were determinants of trajectory membership for general anxiety (all P <or= 0.002), whereas Type D (P = 0.001), social support (P = 0.02), and ICD shock (P < 0.001) determined trajectory membership for device-related concerns. CONCLUSION: The course of general anxiety in ICD patients was stable the first year post implantation, whereas device-related concerns fluctuated more. Type D personality and social support were determinants of trajectory membership for all outcomes, whereas ICD shock was related to device-related concerns only. A simple pre-implant screening may help identify patients at risk for high-distress trajectory membership.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychometric Characteristics of the Multidimensional Scale of Perceived Social Support
Zimet, G. D., Powell, S. S., Farley, G. K., Werkman, S., & Berkoff, K. A. (1990) · Journal of Personality Assessment · doi:10.1080/00223891.1990.9674095 · Cited by 4,855 · cited 2×
“98 in non-clinical samples.(22,23) In a recent study of a mixed Dutch and Danish sample of ICD patients, partners of ICD patients, and patients with CHF, we confirmed the factor structure of the MSPSS and found a Cronbach’s a for the total scale of 0.”
Psychometric Characteristics of the Multidimensional Scale of Perceived Social Support
Zimet, G., Powell, S., Farley, G., Werkman, S., & Berkoff, K. (1990) · Journal of Personality Assessment · doi:10.1207/s15327752jpa5503&4_17 · Cited by 4,854
Quality of life in the Canadian Implantable Defibrillator Study (CIDS)
Irvine, J., Dorian, P., Baker, B., O'Brien, B. J., Roberts, R., Gent, M., Newman, D., & Connolly, S. J. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124049 · Cited by 368
Emotional and physical precipitants of ventricular arrhythmia
Lampert, R., Joska, T., Burg, M. M., Batsford, W. P., McPherson, C. A., & Jain, D. (2002) · Circulation · doi:10.1161/01.cir.0000031733.51374.c1 · Cited by 347
Pedersen, S. S., van Domburg, R. T., Theuns, D. A. M. J., Jordaens, L., & Erdman, R. A. M. (2004) · Psychosomatic Medicine · doi:10.1097/01.psy.0000132874.52202.21 · Cited by 207
Self-citationMiddeldorp, C. M., Birley, A. J., Cath, D. C., Gillespie, N. A., Willemsen, G., Statham, D. J., de Geus, E. J. C., Andrews, J. G., van Dyck, R., Beem, A. L., et al. (2005) · Twin Research and Human Genetics · doi:10.1375/183242705774860123 · Cited by 65
Cited by
Cognitive behavioral treatment of insomnia
Williams, J., Roth, A., Vatthauer, K., & McCrae, C. S. (2013) · Chest · doi:10.1378/chest.12-0731 · Cited by 123
Pedersen, S. S., Knudsen, C., Dilling, K., Sandgaard, N. C. F., & Johansen, J. B. (2016) · Europace · doi:10.1093/europace/euw109 · Cited by 43
Self-citationLANG, S., BECKER, R., WILKE, S., HARTMANN, M., HERZOG, W., & LÖWE, B. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12276 · Cited by 36
Psychological distress in patients with an implantable cardioverter defibrillator and their partners
Rottmann, N., Skov, O., Andersen, C. M., Theuns, D. A. M. J., & Pedersen, S. S. (2018) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2018.07.010 · Cited by 28
“In line with the literature on social support and research with ICD patients [16, 18, 19, 27], high levels of perceived social support had a positive influence on psychological adjustment over time.”
BackgroundResultSelf-citationTavenaux, M., Ginzburg, D. M., Boukacem, A., Sperzel, J., Hamm, C., & Jordan, J. (2011) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-011-0144-z · Cited by 2
Metadata
- Authors
- Pedersen, S. S., Theuns, D. A. M. J., Jordaens, L., & Kupper, N.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-05-27
- Volume
- 12
- Issue
- 8
- Pages
- 1119-1126
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2052480919
- Cited by
- 65
- References
- 6
- FWCI
- 5.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Course of anxiety and device-related concerns in implantable cardioverter defibrillator patients the first year post implantation. https://app.cochat.ai/papers/10.1093/europace/euq154
- The paper
- Pedersen, S. S., Theuns, D. A. M. J., Jordaens, L., & Kupper, N. (2010). Course of anxiety and device-related concerns in implantable cardioverter defibrillator patients the first year post implantation. Europace. https://doi.org/10.1093/europace/euq154
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.