Management of patients receiving implantable cardiac defibrillator shocks: Recommendations for acute and long-term patient management
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Atrial fibrillation Antitachycardia pacing Cardiac resynchronization therapy European Heart Rhythm Association Electrical storm Heart Rhythm Society Implantable cardiac defibrillator Sudden cardiac death Selective serotonin receptor inhibitor Ventricular fibrillation Ventricular tachycardia This expert consensus aims to provide guidance for the management of patients receiving one or multiple shocks from an ICD. The document expresses the view of a multidisciplinary group of experts in the fields of general adult cardiology, ICD treatment, invasive electrophysiology, and psychosomatic medicine. A variety of clinical settings, including emergency medicine, general cardiology, and interventional electrophysiology, are addressed as well as the different groups of clinicians involved in the care of these patients. To cover different levels of expertise in ICD treatment, it is intended to provide comprehensive information ranging from a basic explanation of how an ICD works to specialist advice for device programming. Almost 30 years after the first human implants, ICD therapy has become the treatment of choice in patients at risk of developing malignant ventricular arrhythmias.1,2 Accordingly, the number of patients implanted with an ICD has increased substantially over the past decade,3 mainly as a consequence of the expansion of ICD indications into the field of primary prevention of SCD in patients with decreased left ventricular function. In 2008, ∼120 000 patients received an ICD worldwide.3 As a result of the growing number of ICD patients, ICD-related problems are increasingly encountered and patients with one or multiple shocks are to day frequently seen at emergency departments, hospital wards, or ICD clinics. Therefore, personnel working in these environments should have specific knowledge concerning the management of ICD-related problems. Table 1 summarizes the most common causes of ICD shocks. Trials reported appropriate therapies in 17–64% of patients, whereas inappropriate shocks, most often caused by supraventricular tachycardia, occurred in 10–24%.4 Among patients enrolled in primary prevention ICD trials, women experienced less appropriate ICD interventions than men.5 Modern device algorithms facilitate effective termination of VT without shock delivery by ATP, discrimination between supraventricular tachycardia and VT, and prolonged detection windows. Therefore, we consider shocks delivered to terminate non-life-threatening or non-severely symptomatic arrhythmia as ‘unnecessary’. Although patients generally report the number of perceived shocks with reasonably accuracy,6 phantom shocks, a sensation of ICD therapies that cannot be confirmed by device interrogation, may occasionally occur. Causes of ICD shock delivery Modified from Gehi et al.109 Causes of ICD shock delivery Modified from Gehi et al.109 Patients who received shock therapies should be subjected to a careful assessment of their clinical status and device function. ICD shocks are a powerful risk marker for subsequent clinical events. In patients with a primary preventive ICD indication, both appropriate and inappropriate shocks are associated with a marked increase in mortality, particularly due to death from progressive heart failure.7,8 Possible explanations for this association include that arrhythmia on the ventricular and/or supraventricular level can be a harbinger of deteriorating heart failure, but it has also be proposed that defibrillator shocks cause cellular damage and exert negative inotropic effects, especially in patients receiving multiple therapies.9–11 Importantly, ICD shocks are often a very unpleasant experience and may cause acute and chronic psychological distress, anxiety, and decreased quality of life.12 Consequently, assessment and therapy to relieve distress and anxiety should be an integral part of treatment algorithms for post-shock ICD patients. In addition, early catheter ablation has recently been shown significant benefit in ICD recipients13,14 and should be considered in shock patients. The management of patients receiving ICD shocks is often complex and involves a variety of specialties and professions. Often, clinicians with no specialized training in the field feel uncomfortable taking responsibility for ICD patients. However, the increasing number of patients presenting after shock delivery makes it compulsory to ensure that appropriate treatment is delivered throughout the chain of care, in particular during the initial phase after shock delivery. An ICD system consists of a pulse generator, usually implanted below the left or the right clavicle, and one to three thin electrodes placed transvenously into different chambers of the heart (Figure 1). One electrode is always inserted in the right ventricle (in case this being the only lead, the system is called a ‘single-chamber ICD’). In many patients, a dual-chamber ICD with a right atrial and a right ventricular lead is implanted. Selected patie
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Spironolactone on Morbidity and Mortality in Patients with Severe Heart Failure
Pitt, B., Zannad, F., Remme, W. J., Cody, R., Castaigne, A., Perez, A., Palensky, J., & Wittes, J. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909023411001 · Cited by 9,214 · cited 1×
“…blockers have shown to be effective in the primary prevention of SCD in high-risk individuals with systolic left ventricular dysfunction 64,65 and may be effective as an adjunct to ICDs and/or CRT, both in the primary and the secondary prevention of SCD. 66,67 Device programming…”
Pitt, B., Remme, W., Zannad, F., Neaton, J., Martinez, F., Roniker, B., Bittman, R., Hurley, S., Kleiman, J., & Gatlin, M. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa030207 · Cited by 4,941
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
The DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959 · cited 1×
“More recently, the concept of prophylactic catheter ablation of VT in post-myocardial infarction patients with a secondary ICD indication has been introduced.(13,14) However, the results of larger studies should be awaited before prophylactic ablation can be recommended.”
BackgroundSchron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
Prevention of Implantable-Defibrillator Shocks by Treatment with Sotalol
Pacifico, A., Hohnloser, S. H., Williams, J. H., Tao, B., Saksena, S., Henry, P. D., & Prystowsky, E. N. (1999) · New England Journal of Medicine · doi:10.1056/nejm199906173402402 · Cited by 422
Quality of life in the Canadian Implantable Defibrillator Study (CIDS)
Irvine, J., Dorian, P., Baker, B., O'Brien, B. J., Roberts, R., Gent, M., Newman, D., & Connolly, S. J. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124049 · Cited by 368
Cited by
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
Self-citationPriori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Self-citation(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., Mahrholdt, H., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0212 · Cited by 341
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Europace · doi:10.1093/europace/euu194 · Cited by 327
Metadata
- Authors
- Braunschweig, F., Boriani, G., Bauer, A., Hatala, R., Herrmann-Lingen, C., Kautzner, J., Pedersen, S. S., Pehrson, S., Ricci, R., & Schalij, M. J.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-10-25
- Volume
- 12
- Issue
- 12
- Pages
- 1673-1690
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2112780846
- Cited by
- 113
- References
- 17
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Management of patients receiving implantable cardiac defibrillator shocks: Recommendations for acute and long-term patient management. https://app.cochat.ai/papers/10.1093/europace/euq316
- The paper
- Braunschweig, F., Boriani, G., Bauer, A., Hatala, R., Herrmann-Lingen, C., Kautzner, J., Pedersen, S. S., Pehrson, S., Ricci, R., & Schalij, M. J. (2010). Management of patients receiving implantable cardiac defibrillator shocks: Recommendations for acute and long-term patient management. Europace. https://doi.org/10.1093/europace/euq316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.