Catheter ablation of atrial fibrillation in patients with therapeutic oral anticoagulation treatment
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
AIMS: Current guidelines recommend discontinuation of oral anticoagulation treatment (OAT) and switch to heparin 2-5 days before catheter ablation of atrial fibrillation (AF). However, increasing evidence leans against the 'bridge therapy' and support continuation of OAT during the procedure. METHODS AND RESULTS: We evaluated the safety of AF ablation among patients with therapeutic OAT. The study population comprised 193 consecutive patients who underwent 228 AF ablation procedures guided by electroanatomical mapping. Periprocedural international normalized ratio was <2 (1.6 ± 0.3) in 103 cases (Group 1) and ≥2 (2.4 ± 0.4) in 125 cases (Group 2). Heparin (5000 IU bolus followed by continuous infusion through an open-irrigated ablation catheter) was used in both groups. No intracardiac echocardiographic guidance was used and activated clotting time (ACT) was not monitored. The incidence of major (intracranial bleeding, tamponade, bleeding that required surgical intervention, or blood transfusion) and minor bleeding complications and all thrombo-embolic events were registered during the 3-month follow-up. There was no statistical difference in major (P = 1.0) and minor complications (P = 0.74) between the groups. The bleeding complications included one surgically corrected groin haematoma in both groups (0.9%), 25 small haematomas at the puncture site (11 in Group 1 (10.7%) and 14 in Group 2 (11.2%), P = 0.90), and two minor pericardial effusions in Group 1. In Group 2, one patient had ischaemic stroke 16 days after the procedure. CONCLUSION: Transseptal puncture and AF ablation can be performed safely in patients with ongoing OAT without intracardiac echocardiographic guidance and ACT monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Impact of Atrial Fibrillation on the Risk of Death: The Framingham Heart Study
Benjamin, E. J., Wolf, P. A., D’Agostino, R. B., Silbershatz, H., Kannel, W. B., & Levy, D. (1998) · Circulation · doi:10.1161/01.cir.98.10.946 · Cited by 4,575
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Lifetime Risk for Development of Atrial Fibrillation: The Framingham Heart Study
Lloyd-Jones, D. M., Wang, T. J., Leip, E. P., Larson, M. G., Levy, D., Vasan, R. S., D’Agostino, R. B., Massaro, J. M., Beiser, A., Wolf, P. A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000140263.20897.42 · Cited by 2,041
Stewart, S., Hart, C. L., Hole, D. J., & McMurray, J. J. V. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01236-6 · Cited by 1,562
Quality of life in patients with atrial fibrillation: a systematic review
Thrall, G., Lane, D., Carroll, D., & Lip, G. Y. H. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.10.057 · Cited by 697
Flaker, G. C., Belew, K., Beckman, K., Vidaillet, H., Kron, J., Safford, R., Mickel, M., & Barrell, P. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.06.032 · Cited by 341
DAGRES, N., HINDRICKS, G., KOTTKAMP, H., SOMMER, P., GASPAR, T., BODE, K., ARYA, A., HUSSER, D., RALLIDIS, L. S., KREMASTINOS, D. T., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01493.x · Cited by 279
Cited by
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs253 · Cited by 2,899
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Metadata
- Authors
- Hakalahti, A., Uusimaa, P., Ylitalo, K., & Raatikainen, M. J. P.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-03-11
- Volume
- 13
- Issue
- 5
- Pages
- 640-645
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2074064477
- Cited by
- 75
- References
- 8
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.