Implantable loop recorders are cost-effective when used to investigate transient loss of consciousness which is either suspected to be arrhythmic or remains unexplained
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
AIMS: To assess the cost-effectiveness of implantable loop recorders (ILRs) in people with transient loss of consciousness (TLoC), which, after initial assessment and specialist cardiovascular assessment, is either suspected to be arrhythmic in origin or remains unexplained. This analysis was conducted to inform clinical guideline recommendations made by the National Institute for Health and Clinical Excellence (NICE) on the management of TLoC. METHODS AND RESULTS: Decision analytic modelling was used to estimate the costs and benefits of using ILRs compared with a strategy of no further diagnostic testing. Diagnostic outcomes were estimated from a systematic review and used to populate a decision tree model. To capture the main consequences of diagnosis, the costs and benefits of treatment for several clinically significant arrhythmias were estimated within the model. We used a cost-utility approach, in which benefits are measured using quality adjusted life years (QALYs), and took a UK National Health Service (NHS) and personal social services perspective. The cost per QALY was £17,400 in patients with unexplained syncope and £16,400 in patients with suspected arrhythmic syncope. Sensitivity analysis found that the cost-effectiveness estimates are fairly robust despite the areas of uncertainty identified in the evidence and assumptions used to inform the model. CONCLUSIONS: Implantable loop recorder monitoring is likely to be a cost-effective strategy in people presenting to the UK NHS who are experiencing infrequent episodes of TLoC which either remain unexplained or are suspected to be arrhythmic after initial assessment and specialist cardiovascular assessment. Implantable loop recorder monitoring has been recommended by NICE for these populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
The clinical impact of implantable loop recorders in patients with syncope
Farwell, D. J., Freemantle, N., & Sulke, N. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi602 · Cited by 219 · cited 1×
“In a secondary analysis we considered a comparison of ILR against conventional testing for patients with unexplained syncope, because there were RCT data available for this comparison from a UK setting.(16,17) The diagnostic event rates for this comparison were derived directly from the trial (see Table 28 of the guid…”
MethodBrignole, M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl164 · Cited by 145
Survival in second degree atrioventricular block
Shaw, D. B., Kekwick, C. A., Veale, D., Gowers, J., & Whistance, T. (1985) · Heart · doi:10.1136/hrt.53.6.587 · Cited by 132 · cited 4×
“with second degree AV block evident on 12-lead ECG who were included in the Devon Heart Block and Bradycardia Survey.(13) There was also considerable uncertainty regarding the HRQoL”
MethodInfluentialUse of implantable loop recorders in the diagnosis and management of syncope*1
FARWELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.010 · Cited by 132
Does the use of a syncope diagnostic protocol improve the investigation and management of syncope?
Farwell, D. J., & Sulke, A. N. (2004) · Heart · doi:10.1136/heart.90.1.52 · Cited by 109
Cited by
Podoleanu, C., DaCosta, A., Defaye, P., Taieb, J., Galley, D., Bru, P., Maury, P., Mabo, P., Boveda, S., Cellarier, G., et al. (2014) · Archives of Cardiovascular Diseases · doi:10.1016/j.acvd.2014.05.009 · Cited by 93
Locati, E. T., Moya, A., Oliveira, M., Tanner, H., Willems, R., Lunati, M., & Brignole, M. (2016) · Europace · doi:10.1093/europace/euv311 · Cited by 95
Key challenges in the current management of syncope
Sutton, R., Brignole, M., & Benditt, D. G. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2012.102 · Cited by 33
Edvardsson, N., Wolff, C., Tsintzos, S., Rieger, G., & Linker, N. J. (2015) · Europace · doi:10.1093/europace/euu412 · Cited by 29
“An earlier ILR implant rather than repetition of already non-diagnostic tests would seem more reasonable and is consistent with the current guidelines,(5) with a good chance of being costeffective in comparison with unstructured conventional testing.(19) Tests such as neurological evaluation or blood tests are only in…”
Result
Metadata
- Authors
- Davis, S., Westby, M., Pitcher, D., & Petkar, S.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-11-08
- Volume
- 14
- Issue
- 3
- Pages
- 402-409
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2077080083
- Cited by
- 40
- References
- 6
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implantable loop recorders are cost-effective when used to investigate transient loss of consciousness which is either suspected to be arrhythmic or remains unexplained. https://app.cochat.ai/papers/10.1093/europace/eur343
- The paper
- Davis, S., Westby, M., Pitcher, D., & Petkar, S. (2012). Implantable loop recorders are cost-effective when used to investigate transient loss of consciousness which is either suspected to be arrhythmic or remains unexplained. Europace. https://doi.org/10.1093/europace/eur343
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.