CoChat

Empiric pacemaker compared with a monitoring strategy in patients with syncope and bifascicular conduction block--rationale and design of the Syncope: Pacing or Recording in ThE Later Years (SPRITELY) study

Open access
Krahn, A. D., Morillo, C. A., Kus, T., Manns, B., Rose, S., Brignole, M., Sheldon, R. S. · 2012 · Europace
Cited by 42

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

AIM: This study seeks to identify the optimal management strategy for patients with syncope in the context of bifascicular block and preserved left ventricular systolic function. METHODS AND RESULTS: This multicentre, randomized, open label, parallel group pragmatic randomized trial will test the hypothesis that a strategy of empiric permanent pacemaker implantation in patients with syncope and bifascicular heart block improves future outcome more effectively than a strategy of therapy guided by prolonged monitoring with an implantable loop recorder (ILR). A total of 120 patients with bifascicular block, preserved left ventricular function, and ≥ 1 syncopal spell in the preceding year will be randomized to receive a permanent pacemaker or ILR in at least 20 centres in Canada, the USA, Asia, and Europe. The primary outcome measure will be a composite of Major Adverse Study-Related Events (MASRE) in a 2-year observation period, wherein the events are death, syncope, symptomatic bradycardia, asymptomatic diagnostic bradycardia, and acute and chronic device complications. Prespecified secondary endpoints will include syncope symptoms, quality of life, and economic burden. CONCLUSION: This trial will provide high-level and generalizable evidence for the use of either permanent pacing or implantable loop recorders as a first line intervention for patients with syncope, preserved systolic function, and bifascicular block.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eus005

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 42

Metadata

Authors
Krahn, A. D., Morillo, C. A., Kus, T., Manns, B., Rose, S., Brignole, M., & Sheldon, R. S.
Venue
Europace
Published
2012-02-08
Volume
14
Issue
7
Pages
1044-1048
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2093384844
Cited by
42
References
16
FWCI
5.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Empiric pacemaker compared with a monitoring strategy in patients with syncope and bifascicular conduction block--rationale and design of the Syncope: Pacing or Recording in ThE Later Years (SPRITELY) study. https://app.cochat.ai/papers/10.1093/europace/eus005
The paper
Krahn, A. D., Morillo, C. A., Kus, T., Manns, B., Rose, S., Brignole, M., & Sheldon, R. S. (2012). Empiric pacemaker compared with a monitoring strategy in patients with syncope and bifascicular conduction block--rationale and design of the Syncope: Pacing or Recording in ThE Later Years (SPRITELY) study. Europace. https://doi.org/10.1093/europace/eus005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.