CoChat

Indications for the use of diagnostic implantable and external ECG loop recorders

Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, Auricchio, A., Lip, G. Y.H., Almendral, J., Kirchhof, P., Aliot, E., Gasparini, M., Braunschweig, F., Document Reviewers, Lip, G. Y.H., Almendral, J., Kirchhof, P., Botto, G. L. · 2009 · Europace

The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.

Abstract

ECG loop recorders have a retrospective (loop) memory which continuously records and deletes the patient's ECG. They include a patient-activation function that allows the patient to activate ECG storage as a result of symptoms and an auto-activation feature that allows the capture of arrhythmic events without relying on patient compliance or perception of symptoms. Loop recorder devices can be both implantable (ILR) and external (ELR). Table 1 summarizes the characteristics of the most common diagnostic loop recorders. The retrospective memory differentiates loop recorders from prospective-only event recorders. While event recorders have some usefulness in patients with intermittent palpitations, they have no indication to detect syncope. Most common implantable and external loop recorders a, coming soon (not yet available); b, mobile cardiac outpatient telemetry; c, depends on Memory Card capacity. *Monitoring duration is determined by the battery longevity for implantable devices and by average maximum patients' compliance for external devices. Most common implantable and external loop recorders a, coming soon (not yet available); b, mobile cardiac outpatient telemetry; c, depends on Memory Card capacity. *Monitoring duration is determined by the battery longevity for implantable devices and by average maximum patients' compliance for external devices. Knowledge of what occurs during a spontaneous event is the ideal gold standard for evaluation. Patients with infrequent short-duration transient symptoms, recurring over weeks or months, are unlikely to be diagnosed by conventional Holter monitoring, since the likelihood of symptom-ECG correlation is very low. Consideration should be given to patient-activated event recording in such patients, but this technique has important limitations that might prevent a successful ECG recording of the event, especially for those with syncope, as it implies the activation of recording by the patients once the patient has already recovered consciousness. In such circumstances, consideration should be given to implantable and external ECG loop recorders. It is likely that loop recorders will become increasingly important, and their use will increasingly be appropriate instead of, or before, many current conventional investigations. This early loop recorder approach implies, on the one hand, the need for careful initial risk stratification in order to exclude from such a strategy patients with potential life-threatening conditions that require immediate hospitalization or intensive evaluation and treatment. On the other hand, as a general rule ECG loop recorders are indicated only when there is a high pre-test probability of identifying an heart rhythm abnormality responsible of symptoms. These conditions will be discussed in the document. Ultimately, technology may allow recording of multiple signals in addition to the ECG (e.g. blood flow or pressure, EEG, etc.) and the automatic immediate wireless transmission of pertinent data to a central monitoring station. Such advances will permit greater emphasis on the documenting and characterizing of spontaneous episodes. Conversely, they will result in less reliance for current diagnostic testing techniques that are largely designed to assess susceptibility to the provocation of syncope or palpitations in the laboratory. The Task Force has classified and ranked the usefulness or efficacy of the recommended procedure and/or treatments and the level of evidence as indicated in the tables below: The Task force was unable to give formal recommendations for non-established indications, i.e. atrial fibrillation and risk stratification, due to the lack of sufficient trial-based evidence. In these fields, loop recorders remain very interesting research tools. Clinical evaluation is enough to establish a likely mechanism of syncope in the majority of patients Exclude high-risk patients, i.e. those with a clear indication for ICD, pacemaker, or other treatments independent of a definite diagnosis of the cause of syncope Be aware that the pre-test selection of the patients influences the subsequent findings. Include patients with a high likelihood of arrhythmic events Include patients with a high probability of recurrence of syncope in a reasonable time period Due to the unpredictability of syncope recurrence, be prepared to wait for a substantial time before obtaining such a correlation Your ideal goal should be to obtain a correlation ECG and are Clinical evaluation is enough to establish a likely mechanism of syncope in the majority of patients Exclude high-risk patients, i.e. those with a clear indication for ICD, pacemaker, or other treatments independent of a definite diagnosis of the cause of syncope Be aware that the pre-test selection of the patients influences the subsequent findings. Include patients with a high likelihood of arrhythmic events Include patients with a high probability of recurrence of syncope in a reasonable ti

Overview

Integrity signals

Registry

Crossref · 10.1093/europace/eup097

Cites

94 of 94 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 94 references

Research works printed but not linked: 7

  1. 2008, Heart, 94, 17
  2. 2005, American heart journal, 148, 326
  3. 1998, Annals of Internal Medicine, 28, 890
  4. 1988, The American journal of cardiology, 58, 1021
  5. 1999, Annals of Internal Medicine, 150, 848
  6. Giada, 2004, Italian heart journal : official journal of the Italian Federation of Cardiology, 5, 581
  7. 2004, Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 10, 2111

Cited by

See all 365

Metadata

Authors
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, Auricchio, A., Lip, G. Y. H., Almendral, J., Kirchhof, P., Aliot, E., Gasparini, M., Braunschweig, F., Reviewers, D., Lip, G. Y. H., Almendral, J., Kirchhof, P., & Botto, G. L.
Corresponding author
Brignole, M.
Venue
Europace
Published
2009-04-28
Volume
11
Issue
5
Pages
671-687
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W1994609836
Cited by
362
References
94
Citations by year
2026: 10 · 2025: 6 · 2024: 12 · 2023: 15 · 2022: 12 · 2021: 29 · 2020: 24 · 2019: 17 · 2018: 25 · 2017: 22 · 2016: 28 · 2015: 27 · 2014: 29 · 2013: 28 · 2012: 14
FWCI
25.69
Type
journal article
Language
en
Open access
closed
Locations
  • EP Europace (publishedVersion)
  • PubMed (publishedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • Pure Amsterdam UMC (submittedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
implantable loop recorder, external loop recorder, syncope, auto-activation, risk stratification, Holter monitoring, diagnostic indications, cardiac monitoring devices, event data recorders, battery life
MeSH terms
Arrhythmias, Cardiac, Electrocardiography, Humans, Monitoring, Physiologic, Syncope

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Indications for the use of diagnostic implantable and external ECG loop recorders. https://app.cochat.ai/papers/10.1093/europace/eup097
The paper
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, Auricchio, A., Lip, G. Y. H., Almendral, J., Kirchhof, P., Aliot, E., Gasparini, M., Braunschweig, F., Reviewers, D., Lip, G. Y. H., . . . Botto, G. L. (2009). Indications for the use of diagnostic implantable and external ECG loop recorders. Europace. https://doi.org/10.1093/europace/eup097

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.