Cited by 81Cardiac pacing and defibrillation studiesCardiac electrophysiology and arrhythmiasCoronary Interventions and Diagnostics

State of the art of leadless pacing

Open access

Abstract

Despite undisputable benefits, conventional pacemaker therapy is associated with specific complications related to the subcutaneous device and the transvenous leads. Recently, two miniaturized leadless pacemakers, Nanostim™ (St. Jude Medical) and Micra™ (Medtronic), which can be completely implanted inside the right ventricle using steerable delivery systems, entered clinical application. The WiCS™-cardiac resynchronisation therapy (CRT) system (wireless cardiac stimulation for CRT, EBR Systems) delivers leadless left ventricular endocardial stimulation for cardiac resynchronization. In addition to obvious cosmetic benefits, leadless pacing systems may have the potential to overcome some complications of conventional pacing. However, acute and long-term complications still remains to be determined, as well as the feasibility of device explantation years after device placement.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euv096

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Market-released leadless devices such as Micra and Nanostim introduce new complications due to integration of a battery into the main body of the pacer.

    “Although the recent FDA approval of the Micra marks a positive step towards leadless devices, it introduces a new set of complications, notably due to their integration of a battery into the main body of the pacer8–10.”

    From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [8]

    The table in “Leadless systems for right ventricle pacing” lists integrated batteries for both Micra and Nanostim. The same section raises unresolved questions about retrieval or implanting another device after battery depletion, but does not establish that battery integration has caused new complications. (LLM, conf=0.85)

    Experimental — accuracy not yet measured
  • Alternative leadless solutions such as energy harvesters and ultrasound-based wireless pacers are hindered by a large device size that leads to mechanically stressed fixation mechanisms.

    “Alternative solutions for leadless devices have been proposed, including utilization of energy harvesters11, 12 and ultrasound-based wireless pacers8, 13, 14. However, these are similarly hindered by a large device size that leads to mechanically stressed fixation mechanisms.”

    From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [8]

    The technological-aspects section describes the ultrasound-based WiCS leadless pacer and its fixation tines, while the future-perspectives section mentions research on harvesting cardiac-motion energy. The paper does not say that either approach is hindered by large device size or that size mechanically stresses its fixation mechanism (no page numbers are available in our copy). (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 22

  1. [2]Spickler JW Rasor NS Kezdi P Misra SN Robins KE LeBoeuf C Totally self-contained intracardiac pacemaker. J Electrocardiol 1970; 3: 325– 31. 5517593
  2. [3]Vardas PE Politopoulos E Manios E Parthenakis F Tsagarakis C A miniature pacemaker introduced intravenously and implanted endocardially. Preliminary findings form an experimental study. Eur J CPE 1991; 1: 27– 30.
  3. [4]Chauveau S Brink PR Cohen IS Stem cell-based biological pacemakers from proof of principle to therapy: a review. Cytotherapy 2014; 16: 873– 80. 24831844 PMC4051829
  4. [5]Echt DS Cowan MW Riley RE Brisken AF Feasibility and safety of a novel technology for pacing without leads. Heart Rhythm 2006; 3: 1202– 6. 17018352
  5. [6]Lee KL Lau CP Tse HF Echt DS Heaven D Smith W First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices. J Am Coll Cardiol 2007; 50: 877– 83. 17719475
  6. [7]Wieneke H Konorza T Erbel R Kisker E Leadless pacing of the heart using induction technology: a feasibility study. Pacing Clin Electrophysiol 2009; 32: 177– 83. 19170906
  7. [9]Cleland JG Daubert JC Erdmann E Freemantle N Gras D Kappenberger L The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med 2005; 352: 1539. 15753115
  8. [12]Gras D Böcker D Lunati M Wellens HJ Calvert M Freemantle N Implantation of cardiac resynchronization therapy systems in the CARE-HF trial: procedural success rate and safety. Europace 2007; 9: 516– 22. 17540662
  9. [13]Garrigue S Jaïs P Espil G Labeque JN Hocini M Shah DC Comparison of chronic biventricular pacing between epicardial and endocardial left ventricular stimulation using Doppler tissue imaging in patients with heart failure. Am J Cardiol 2001; 88: 858– 62. 11676947
  10. [14]Spragg DD Dong J Fetics BJ Helm R Marine JE Cheng A Optimal left ventricular endocardial pacing sites for cardiac resynchronization therapy in patients with ischemic cardiomyopathy. J Am Coll Cardiol 2010; 56: 774– 81. 20797490
  11. [15]Bordachar P Grenz N Jais P Ritter P Leclercq C Morgan JM Left ventricular endocardial or triventricular pacing to optimize cardiac resynchronization therapy in a chronic canine model of ischemic heart failure. Am J Physiol Heart Circ Physiol 2012; 303: H207– 15. 22561299
  12. [16]Bordachar P Derval N Ploux S Garrigue S Ritter P Haissaguerre M Left ventricular endocardial stimulation for severe heart failure. J Am Coll Cardiol 2010; 56: 747– 53. 20797486
  13. [17]van Gelder BM Scheffer MG Meijer A Bracke FA Transseptal endocardial left ventricular pacing: an alternative technique for coronary sinus lead placement in cardiac resynchronization therapy. Heart Rhythm 2007; 4: 454– 60. 17399634
  14. [18]Betts TR Gamble JH Khiani R Bashir Y Rajappan K Development of a technique for left ventricular endocardial pacing via puncture of the interventricular septum. Circ Arrhythm Electrophysiol 2014; 7: 17– 22. 24425419
  15. [19]Auricchio A Delnoy PP Butter C Brachmann J Van Erven L Spitzer S Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study. Europace 2014; 16: 681– 8. 24497573
  16. [20]DeFaria Yeh D Lonergan KL Fu D Yeh RW Echt DS Foster E Clinical factors and echocardiographic techniques related to the presence, size, and location of acoustic windows for leadless cardiac pacing. Europace 2011; 13: 1760– 5. 21798878
  17. [21]Reddy VY Knops RE Sperzel J Miller MA Petru J Simon J Permanent leadless cardiac pacing: results of the LEADLESS trial. Circulation 2014; 129: 1466– 71. 24664277
  18. [23]Bonner M Eggen M Chronic Animal Study of Leadless Pacer Design (abstract). Heart Rhythm 2011; 8: S1.
  19. [24]Bonner M Eggen M Depalo J Sheldon T Williams E Assessment of leadless pacemaker performance (abstract). Eur Heart J 2013; 34: 347.
  20. [25]Bonner M Eggen M Hilpisch K Sheldon T Williams E Performance of the Medtronic Micra transcatheter pacemaker in a GLP study (abstract). Heart Rhythm 2014; 11: S19.
  21. [26]Bonner M Neafus N Byrd C Schaerf R Goode L Extraction of the Micra transcatheter pacemaker system (abstract). Heart Rhythm 2014; 11: S342.
  22. [28]Neuzil P Reddy VY Merkely B Geller L Molnar L Bednarek J Implantable intravascular defibrillator: defibrillation thresholds of an intravascular cardioverter-defibrillator compared with those of a conventional ICD in humans. Heart Rhythm 2014; 11: 210– 5. 24144885

Cited by

Sorted by citations

Authors
Sperzel, J., Burri, H., Gras, D., Tjong, F. V. Y., Knops, R. E., Hindricks, G., Steinwender, C., & Defaye, P.
Affiliations
  • Kerckhoff Klinik (DE)
  • University Hospital of Geneva (CH)
  • Nouvelles Cliniques Nantaises (FR)
  • Amsterdam UMC Location University of Amsterdam (NL)
  • Leipzig University (DE)
  • Johannes Kepler University of Linz (AT)
  • Centre Hospitalier Universitaire de Grenoble (FR)
Corresponding author
Sperzel, Johannes
Venue
Europace
Published
2015-05-29
Volume
17
Issue
10
Pages
1508-1513
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2126563732
Cited by
81
References
4
Citations by year
2026: 1 · 2025: 3 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 9 · 2019: 8 · 2018: 11 · 2017: 21 · 2016: 14 · 2015: 4
FWCI
12.13
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • EP Europace (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • Pure Amsterdam UMC (publishedVersion, other-oa)
  • Archive ouverte UNIGE (University of Geneva) (publishedVersion, other-oa)
  • reroDoc Digital Library (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by-nc)
Funders
St. Jude Medical
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Surgery › Coronary Interventions and Diagnostics
Keywords
leadless pacing, leadless pacemaker, cardiac resynchronization therapy, Micra, left ventricular endocardial pacing, device complications, device explantation, pacemaker leads
MeSH terms
Endocardium, Equipment Design, Heart Ventricles, Humans, Treatment Outcome, Prostheses and Implants, Cardiac Resynchronization Therapy Devices, Cardiac Catheters

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review