Smart detection of atrial fibrillation
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
AIMS: Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice, and its paroxysmal nature makes its detection challenging. In this trial, we evaluated a novel App for its accuracy to differentiate between patients in AF and patients in sinus rhythm (SR) using the plethysmographic sensor of an iPhone 4S and the integrated LED only. METHODS AND RESULTS: For signal acquisition, we used an iPhone 4S, positioned with the camera lens and LED light on the index fingertip. A 5 min video file was recorded with the pulse wave extracted from the green light spectrum of the signal. RR intervals were automatically identified. For discrimination between AF and SR, we tested three different statistical methods. Normalized root mean square of successive difference of RR intervals (nRMSSD), Shannon entropy (ShE), and SD1/SD2 index extracted from a Poincaré plot. Eighty patients were included in the study (40 patients in AF and 40 patients in SR at the time of examination). For discrimination between AF and SR, ShE yielded the highest sensitivity and specificity with 85 and 95%, respectively. Applying a tachogram filter resulted in an improved sensitivity of 87.5%, when combining ShE and nRMSSD, while specificity remained stable at 95%. A combination of SD1/SD2 index and nRMSSD led to further improvement and resulted in a sensitivity and specificity of 95%. CONCLUSION: The algorithm tested reliably discriminated between SR and AF based on pulse wave signals from a smartphone camera only. Implementation of this algorithm into a smartwatch is the next logical step.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100 · cited 1×
“gov Identifier: NCT01938248).(4,5) The use of smartphones and smartwatches in medical practice is currently being evaluated.”
BackgroundAtrial fibrillation in patients with cryptogenic stroke
Gladstone, D. J., Spring, M., Dorian, P., Panzov, V., Thorpe, K. E., Hall, J., Vaid, H., O'Donnell, M., Laupacis, A., Côté, R., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311376 · Cited by 1,276 · cited 1×
“Recent trials support the use of intensified diagnostic strategies to detect AF in selected patients, although the methods used are costly or inconvenient.(2,3) Even with the rapidly increasing knowledge in this field, the relevance of subclinical AF and the temporal correlation between AF and stroke remains controver…”
BackgroundMcManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Ziegler, P. D., Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Koehler, J. L., & Hilker, C. E. (2010) · Stroke · doi:10.1161/strokeaha.109.571455 · Cited by 173 · cited 1×
“gov Identifier: NCT01938248).(4,5) The use of smartphones and smartwatches in medical practice is currently being evaluated.”
Background
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Self-citationMobile Photoplethysmographic Technology to Detect Atrial Fibrillation
Guo, Y., Wang, H., Zhang, H., Liu, T., Liang, Z., Xia, Y., Yan, L., Xing, Y., Shi, H., Li, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.08.019 · Cited by 489
Self-citationPhotoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
The WATCH AF trial: SmartWATCHes for detection of atrial fibrillation
Dörr, M., Nohturfft, V., Brasier, N., Bosshard, E., Djurdjevic, A., Gross, S., Raichle, C. J., Rhinisperger, M., Stöckli, R., & Eckstein, J. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.10.006 · Cited by 245
Metadata
- Authors
- Krivoshei, L., Weber, S., Burkard, T., Maseli, A., Brasier, N., Kühne, M., Conen, D., Huebner, T., Seeck, A., & Eckstein, J.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-07-01
- Volume
- 19
- Issue
- 5
- Pages
- euw125
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2461505578
- Cited by
- 112
- References
- 5
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Smart detection of atrial fibrillation. https://app.cochat.ai/papers/10.1093/europace/euw125
- The paper
- Krivoshei, L., Weber, S., Burkard, T., Maseli, A., Brasier, N., Kühne, M., Conen, D., Huebner, T., Seeck, A., & Eckstein, J. (2016). Smart detection of atrial fibrillation. Europace. https://doi.org/10.1093/europace/euw125
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.