Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Atrioventricular node ablation and His bundle pacing

Open access
Vijayaraman, Pugazhendhi, Subzposh, Faiz A, Naperkowski, Angela·2017·EP Europace

Abstract

AIMS: Atrioventricular node ablation (AVNA) and right ventricular pacing (RVP) are effective therapies for patients with atrial fibrillation (AF) and rapid ventricular rates. His bundle pacing (HBP) is a physiologic alternative to RVP. The aim of our study is to assess the feasibility and safety of HBP in patients undergoing AVNA and its effect on left ventricular (LV) function. METHODS AND RESULTS: Permanent HBP is the preferred form of ventricular pacing at our institute. Atrioventricular node ablation and HBP were performed in patients with AF and difficulty in rate control. His bundle pacing implant characteristics and thresholds were recorded. Fluoroscopic relationship of AVNA site to HBP lead electrodes was documented. Left ventricular ejection fraction (LVEF) and New York Heart Association (NYHA) functional class at baseline and during follow-up were assessed. Forty-two patients underwent HBP and AVNA: age 74 ± 11 years; men 45%; HTN 64%; DM 19%; CAD 36%; permanent AF 40%; cardiomyopathy 55%. His bundle pacing was successful in 40 of 42 patients (95%). Successful AVNA site was at or below the ring electrode in 22 (no acute change in HBP threshold); above the ring electrode in 13 and left side in 2 pts (acute increase in HBP threshold in 7 of 15 pts). Final HBP threshold at implant was 1 ± 0.8 V@1 ms and increased to 1.6 ± 1.2 V@1 ms during a mean follow-up of 19 ± 14 months. Left ventricular ejection fraction increased from 43 ± 13% to 50 ± 11% (P = 0.01). New York Heart Association functional status improved from 2.5 ± 0.5 to 1.9 ± 0.5 (P = 0.04). CONCLUSION: Atrioventricular node ablation and HBP were successful in 95% of patients. His bundle pacing lead characteristics remained relatively stable. Left ventricular ejection fraction improved significantly during follow-up. His bundle pacing is feasible, safe and effective in pts undergoing AVNA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eux263

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 161

Metadata

Authors
Vijayaraman, P., Subzposh, F. A., & Naperkowski, A.
Venue
EP Europace
Published
2017-12-01
Volume
19
Issue
suppl_4
Pages
iv10-iv16
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2774630854
Cited by
161
References
1
FWCI
10.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Atrioventricular node ablation and His bundle pacing. https://app.cochat.ai/papers/10.1093/europace/eux263
The paper
Vijayaraman, P., Subzposh, F. A., & Naperkowski, A. (2017). Atrioventricular node ablation and His bundle pacing. EP Europace. https://doi.org/10.1093/europace/eux263

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.