Continuous monitoring after atrial fibrillation ablation: the LINQ AF study
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Aims: To study device performance, arrhythmia recurrence characteristics, and methods of outcome assessment using a novel implantable cardiac monitor (ICM) in patients undergoing ablation for atrial fibrillation (AF). Methods and results: In 419 consecutive patients undergoing first-time catheter ablation for symptomatic paroxysmal (n = 224) or persistent (n = 195) AF an ICM was injected at the end of the procedure. Telemedicine staff ensured full episode transmission coverage and manually evaluated all automatic arrhythmia episodes. Device detection metrics were calculated for ≥2, ≥6, and ≥10 min AF detection durations. Four methods of outcome assessment were studied: continuous recurrence analysis, discontinuous recurrence analysis, AF-burden analysis, and analysis of individual rhythm profiles. A total of 43 673 automatic AF episodes were transmitted over a follow-up of 15 ± 6 months. Episode-based positive predictive values changed significantly with longer AF detection durations (70.5% for ≥2 min, 81.8% for ≥6 min, and 85.9% for ≥10 min). Patients with exclusive short episode recurrences (≥2 to <6 min) were rare and their arrhythmia detection was clinically irrelevant. Different methods of outcome assessment showed a large variation (46-79%) in ablation success. Individual rhythm characteristics and subclinical AF added to this inconsistency. Analysis of AF-burden and individual rhythm profiles were least influenced and showed successful treatment in 60-70% of the patients. Conclusion: We suggest AF detection duration >6 min and AF burden >0.1% as a standardized outcome definition for AF studies to come in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Hindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506 · cited 1×
“Success rates of atrial fibrillation (AF) ablation remain controversial because many previous studies are based on symptom-reporting and discontinuous monitoring, which underestimate true recurrence rates.(1,2) From a clinical perspective it is essential to rely upon appropriate detection of AF to make decisions conce…”
BackgroundSelf-citationBoriani, G., Glotzer, T. V., Santini, M., West, T. M., De Melis, M., Sepsi, M., Gasparini, M., Lewalter, T., Camm, J. A., & Singer, D. E. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht491 · Cited by 427
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Verma, A., Champagne, J., Sapp, J., Essebag, V., Novak, P., Skanes, A., Morillo, C. A., Khaykin, Y., & Birnie, D. (2013) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2013.1561 · Cited by 315
Sanders, P., Pürerfellner, H., Pokushalov, E., Sarkar, S., Di Bacco, M., Maus, B., & Dekker, L. R. C. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.03.005 · Cited by 162
Cited by
Low-Voltage Myocardium-Guided Ablation Trial of Persistent Atrial Fibrillation
Huo, Y., Gaspar, T., Schönbauer, R., Wójcik, M., Fiedler, L., Roithinger, F. X., Martinek, M., Pürerfellner, H., Kirstein, B., Richter, U., et al. (2022) · NEJM Evidence · doi:10.1056/evidoa2200141 · Cited by 275
Self-citationWearables in cardiology: Here to stay
Dagher, L., Shi, H., Zhao, Y., & Marrouche, N. F. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.02.023 · Cited by 107
Veltmann, C., Bosch, R., Boer, J., Endres, M., Frankenstein, L., Gröschel, K., Hansen, C., & Straube, F. (2023) · Die Kardiologie · doi:10.1007/s12181-023-00634-z · Cited by 3
Jilek, C., & Lewalter, T. (2020) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-020-00705-8 · Cited by 1
Metadata
- Authors
- Wechselberger, S., Kronborg, M., Huo, Y., Piorkowski, J., Neudeck, S., Päßler, E., El-Armouche, A., Richter, U., Mayer, J., Ulbrich, S., Pu, L., Kirstein, B., Gaspar, T., & Piorkowski, C.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-04-24
- Volume
- 20
- Issue
- FI_3
- Pages
- f312-f320
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2800349995
- Cited by
- 73
- References
- 7
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous monitoring after atrial fibrillation ablation: the LINQ AF study. https://app.cochat.ai/papers/10.1093/europace/euy038
- The paper
- Wechselberger, S., Kronborg, M., Huo, Y., Piorkowski, J., Neudeck, S., Päßler, E., El-Armouche, A., Richter, U., Mayer, J., Ulbrich, S., Pu, L., Kirstein, B., Gaspar, T., & Piorkowski, C. (2018). Continuous monitoring after atrial fibrillation ablation: the LINQ AF study. EP Europace. https://doi.org/10.1093/europace/euy038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.