Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 229

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum

Hou, Xiaofeng, Qian, Zhiyong, Wang, Yao, Qiu, Yuanhao, Chen, Xing, Jiang, Hai, Jiang, Zeyu, Wu, Hongping, Zhao, Zhongqiang, Zhou, Weihua, Zou, Jiangang · 2019 · EP Europace

Abstract

Aims: Left bundle branch pacing (LBBP) recently emerges as a novel pacing modality. We aimed to evaluate the feasibility and cardiac synchrony of permanent LBBP in bradycardia patients. Methods and results: Left bundle branch pacing was successfully performed in 56 pacemaker-indicated patients with normal cardiac function. Left bundle branch pacing was achieved by penetrating the interventricular septum (IVS) into the left side sub-endocardium with the pacing lead. His-bundle pacing (HBP) was successfully performed in another 29 patients, 19 of whom had right ventricular septal pacing (RVSP) for backup pacing. The QRS duration, left ventricular (LV) activation time (LVAT), and mechanical synchrony using phase analysis of gated SPECT myocardial perfusion imaging were evaluated. Paced QRS duration in LBBP group was significantly shorter than that in RVSP group (117.8 ± 11.0 ms vs. 158.1 ± 11.1 ms, P < 0.0001) and wider than that in HBP group (99.7 ± 15.6 ms, P < 0.0001). Left bundle branch potential was recorded during procedure in 37 patients (67.3%). Left bundle branch pacing patients with potential had shorter LVAT than those without potential (73.1 ± 11.3 ms vs. 83.2 ± 16.8 ms, P = 0.03). Left bundle branch pacing patients with potential had similar LV mechanical synchrony to those in HBP group. R-wave amplitude and capture threshold of LBBP were 17.0 ± 6.7 mV and 0.5 ± 0.1 V, respectively at implant and remained stable during a mean follow-up of 4.5 months without lead-related complications. Conclusion: Permanent LBBP through IVS is safe and feasible in bradycardia patients. Left bundle branch pacing could achieve favourable cardiac electrical and LV mechanical synchrony.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euz188

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 229

Metadata

Authors
Hou, X., Qian, Z., Wang, Y., Qiu, Y., Chen, X., Jiang, H., Jiang, Z., Wu, H., Zhao, Z., Zhou, W., & Zou, J.
Venue
EP Europace
Published
2019-07-19
Volume
21
Issue
11
Pages
1694-1702
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2963358343
Cited by
229
References
4
FWCI
23.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum. https://app.cochat.ai/papers/10.1093/europace/euz188
The paper
Hou, X., Qian, Z., Wang, Y., Qiu, Y., Chen, X., Jiang, H., Jiang, Z., Wu, H., Zhao, Z., Zhou, W., & Zou, J. (2019). Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum. EP Europace. https://doi.org/10.1093/europace/euz188

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.