Manual and automated office measurements in relation to awake ambulatory blood pressure monitoring
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Automated blood pressure (BP) devices are commonly used in doctor's offices. How BP measured on these devices relates to ambulatory BP monitoring is not clear. OBJECTIVE: To assess how well office-based manual and automated BP predicts ambulatory BP. METHODS: Using data on 654 patients, we assessed how well sphygmomanometer measurements and measurements taken with an automated device (BpTRU) predicted results on ambulatory BP monitoring. We assess positive and negative predictive values and overall accuracy. We look at different cut-points for systolic (130, 135 and 140 mmHg) and diastolic (80, 85 and 90 mmHg) BP. RESULTS: A single automated office BP (AOBP) assessment provides superior predictive values and overall accuracy compared to three manual office BP assessments. For systolic BP, the predictive values are ≤69% for any of the cut-points while the positive predictive values for the single automated measurement is between 80.0% and 86.9% and the overall accuracy gets as high as 74% for the 130 mmHg cut-point. For diastolic BP, the automated readings are also more predictive but in this case, it is the negative predictive values that are better, as well as the overall accuracy. CONCLUSIONS: Based on the results, we suggest that 135/85 mmHg continue to be used as the cut-point defining high BP with the BpTRU device. However, future research might suggests that values in a grey zone between 130-139 mmHg systolic and 80-89 mmHg diastolic be confirmed using ambulatory BP monitoring. As well, three AOBP assessments might produce much greater accuracy than the single AOBP assessment used in the study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Sega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Home Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Macdougall, I. C., Bircher, A. J., Eckardt, K.-U., Obrador, G. T., Pollock, C. A., Stenvinkel, P., Swinkels, D. W., Wanner, C., Weiss, G., Chertow, G. M., et al. (2016) · Kidney International · doi:10.1016/j.kint.2015.10.002 · Cited by 482
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., Grant, F. C., & Kaczorowski, J. (2011) · BMJ · doi:10.1136/bmj.d286 · Cited by 285
Self-citationRoerecke, M., Kaczorowski, J., & Myers, M. G. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.6551 · Cited by 216
Metadata
- Authors
- Godwin, M., Birtwhistle, R., Delva, D., Lam, M., Casson, I., MacDonald, S., & Seguin, R.
- Venue
- Family Practice
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-08-18
- Volume
- 28
- Issue
- 1
- Pages
- 110-117
- ISSN
- 0263-2136 (ISSN-L)
- 1460-2229
- OpenAlex
- W2060049722
- Cited by
- 65
- References
- 3
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.