The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Feasibility and measurement properties of the functional reach and thetimed up and go tests in the Canadian study of health and aging
Abstract
BACKGROUND: Physical performance measures may offer advantages over self-report in the functional assessment of older people. Estimates of the feasibility, reliability, and construct validity of these measures in large, heterogeneous samples are necessary to establish their importance relative to traditional measures of function. METHODS: Analysis of clinical data from Phase 2 of the Canadian Study of Health and Aging, a nation-wide representative survey of elderly people in Canada (N = 2,305). RESULTS: Both physical performance measures proved infeasible in many subjects (29.3% for the Timed Up and Go [TUG], 35.9% for the Functional Reach [FR]). Cognitive impairment was the most important determinant of inability to complete the tests. For those able to complete the tests, cognitively unimpaired subjects could reach farther (median 29 cm) and complete the TUG in less time (median 12 seconds) than those cognitively impaired (25 cm for FR, 15 seconds for the TUG). Test-retest reliability between the screening and clinical administrations of the TUG was .56 for all participants (intra-class correlations), .50 for the cognitively unimpaired, and .56 for the cognitively impaired. Construct validity was substantial, and correlations between performance measures and self-report activities of daily living (ADL) measures ranged from .40 to .70. Compared with a global clinical measure of frailty, correlations were more modest (.38 to .60). CONCLUSIONS: The FR and the TUG were not feasible tools in this study. The TUG showed poor test-retest reliability. Our data support the observation that subsequent studies of measurement instruments typically reveal lower performance than the original reports.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons
Podsiadlo, D., & Richardson, S. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01616.x · Cited by 14,418
Health Measurement Scales: A Practical Guide to Their Development and Use
Streiner, D. L., Norman, G. R., & Cairney, J. (1989) · Cited by 9,595
Measuring Health: A Guide to Rating Scales and Questionnaires
McDowell, I., & Newell, C. (1987) · Cited by 4,207
Lower-extremity function in persons over the age of 70 years as a predictor of subsequent disability
Guralnik, J. M., Ferrucci, L., Simonsick, E. M., Salive, M. E., & Wallace, R. B. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503023320902 · Cited by 4,083
Functional Reach: A New Clinical Measure of Balance
Duncan, P. W., Weiner, D. K., Chandler, J., & Studenski, S. (1990) · Journal of Gerontology · doi:10.1093/geronj/45.6.m192 · Cited by 2,873
(1987) · PubMed · Cited by 2,657
CUMULATIVE ILLNESS RATING SCALE
LINN, B. S., LINN, M. W., & GUREL, L. (1968) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1968.tb02103.x · Cited by 2,304
Fillenbaum, G. G., & Smyer, M. A. (1981) · Journal of Gerontology · doi:10.1093/geronj/36.4.428 · Cited by 1,117
Fried, L. P. (1998) · JAMA · doi:10.1001/jama.279.8.585 · Cited by 1,107 · cited 1×
“Baseline self-rated function, and self-rated health, retained important predictive validity, even in the face of physiologic measures such as ejection fraction, carotid artery patency, tibial artery blood pressure, and biochemical indices (25).”
BackgroundFrailty in elderly people: an evolving concept.
Rockwood, K. J., Fox, R. A., Stolee, P., Robertson, D., & Beattie, B. L. (1994) · PubMed · Cited by 791
Cited by
Steffen, T. M., Hacker, T. A., & Mollinger, L. (2002) · Physical Therapy · doi:10.1093/ptj/82.2.128 · Cited by 2,070
Reference Values for the Timed Up and Go Test: A Descriptive Meta-Analysis
Bohannon, R. W. (2006) · Journal of Geriatric Physical Therapy · doi:10.1519/00139143-200608000-00004 · Cited by 1,024
Sexual-dimorphism in human immune system aging
Márquez, E. J., Chung, C.-H., Marches, R., Rossi, R. J., Nehar-Belaid, D., Eroglu, A., Mellert, D. J., Kuchel, G. A., Banchereau, J., & Ucar, D. (2020) · Nature Communications · doi:10.1038/s41467-020-14396-9 · Cited by 584
Properties of the ‘Timed Up and Go’ Test: More than Meets the Eye
Herman, T., Giladi, N., & Hausdorff, J. M. (2011) · Gerontology · doi:10.1159/000314963 · Cited by 572
Beaudart, C., Rolland, Y., Cruz-Jentoft, A. J., Bauer, J. M., Sieber, C., Cooper, C., Al-Daghri, N., Araujo de Carvalho, I., Bautmans, I., Bernabei, R., et al. (2019) · Calcified Tissue International · doi:10.1007/s00223-019-00545-w · Cited by 528
Schoene, D., Wu, S. M. ‐., Mikolaizak, A. S., Menant, J. C., Smith, S. T., Delbaere, K., & Lord, S. R. (2013) · Journal of the American Geriatrics Society · doi:10.1111/jgs.12106 · Cited by 496
Mijnarends, D. M., Meijers, J. M. M., Halfens, R. J. G., ter Borg, S., Luiking, Y. C., Verlaan, S., Schoberer, D., Cruz Jentoft, A. J., van Loon, L. J. C., & Schols, J. M. G. A. (2013) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2012.10.009 · Cited by 475
Bennell, K., Dobson, F., & Hinman, R. (2011) · Arthritis Care & Research · doi:10.1002/acr.20538 · Cited by 463
Vestibular Rehabilitation for Dizziness and Balance Disorders After Concussion
Alsalaheen, B. A., Mucha, A., Morris, L. O., Whitney, S. L., Furman, J. M., Camiolo-Reddy, C. E., Collins, M. W., Lovell, M. R., & Sparto, P. J. (2010) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0b013e3181dde568 · Cited by 447
Ries, J. D., Echternach, J. L., Nof, L., & Gagnon Blodgett, M. (2009) · Physical Therapy · doi:10.2522/ptj.20080258 · Cited by 439
Models, Definitions, and Criteria of Frailty
Hogan, D. B. (2006) · Handbook of Models for Human Aging · doi:10.1016/b978-012369391-4/50051-5 · Cited by 410
Scott, V., Votova, K., Scanlan, A., & Close, J. (2007) · Age and Ageing · doi:10.1093/ageing/afl165 · Cited by 379
Using Timed Up-and-Go to Identify Frail Members of the Older Population
Savva, G. M., Donoghue, O. A., Horgan, F., O'Regan, C., Cronin, H., & Kenny, R. A. (2013) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/gls190 · Cited by 363
Issues for selection of outcome measures in stroke rehabilitation: ICF Participation
Salter, K., Jutai, J., Teasell, R., Foley, N., BItensky, J., & Bayley, M. (2005) · Disability and Rehabilitation · doi:10.1080/0963828040008552 · Cited by 313
Investigation of the timed ‘Up & Go’ test in children
Williams, E. N., Carroll, S. G., Reddihough, D. S., Phillips, B. A., & Galea, M. P. (2005) · Developmental Medicine & Child Neurology · doi:10.1017/s0012162205001027 · Cited by 293
Hornby, T. G., Zemon, D. H., & Campbell, D. (2005) · Physical Therapy · doi:10.1093/ptj/85.1.52 · Cited by 283
Birnie, K., Cooper, R., Martin, R. M., Kuh, D., Sayer, A. A., Alvarado, B. E., Bayer, A., Christensen, K., Cho, S.-I., Cooper, C., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0015564 · Cited by 281
The association between timed up and go test and history of falls: The Tromsø study
Thrane, G., Joakimsen, R. M., & Thornquist, E. (2007) · BMC Geriatrics · doi:10.1186/1471-2318-7-1 · Cited by 256
Testing Functional Performance in People With Parkinson Disease
Brusse, K. J., Zimdars, S., Zalewski, K. R., & Steffen, T. M. (2005) · Physical Therapy · doi:10.1093/ptj/85.2.134 · Cited by 252
The chromatin accessibility signature of human immune aging stems from CD8+ T cells
Ucar, D., Márquez, E. J., Chung, C.-H., Marches, R., Rossi, R. J., Uyar, A., Wu, T.-C., George, J., Stitzel, M. L., Palucka, A. K., et al. (2017) · Journal of Experimental Medicine · doi:10.1084/jem.20170416 · Cited by 200
Metadata
- Venue
- The Journals of Gerontology Series A: Biological Sciences and Medical Sciences
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-02-01
- Volume
- 55
- Issue
- 2
- Pages
- M70-M73
- ISSN
- 1079-5006 (ISSN-L)
- 1758-535X
- OpenAlex
- W210042228
- Cited by
- 284
- References
- 23
- FWCI
- 11.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.