Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Diagnosis of human preimplantation embryo viability

Gardner, David K., Meseguer, Marcos, Rubio, Carmen, Treff, Nathan R. · 2015 · Human Reproduction Update

Abstract

BACKGROUND: Transfer of more than a single embryo in an IVF cycle comes with the finite possibility of a multiple gestation. Even a twin pregnancy confers significant risk to both mother and babies. The move to single-embryo transfer for all patients will be greatly facilitated by the ability to quantify embryo viability. Developments in time-lapse incubation systems have provided new insights into the developmental kinetics of the human preimplantation embryo. Advances in molecular methods of chromosomal analysis have created platforms for highly effective screening of biopsied embryos, while noninvasive analysis of embryo physiology reveals more about the embryo than can be determined by morphology alone. METHODS: Recent developments in time-lapse microscopy, molecular karyotyping and in proteomics and metabolomics have been assessed and presented here in a descriptive review. RESULTS AND CONCLUSIONS: New algorithms are being created for embryo selection based on their developmental kinetics in culture, and the impact of factors such as patient etiology and treatment are being clarified. Potential links between morphokinetic data and embryo karyotype are being elucidated. The introduction of new molecular methods of determining embryo chromosomal complement is proving to be accurate and reproducible, with the future trending toward CGH arrays or next generation sequencing as a rapid and reliable means of analysis, that should be suitable for each IVF clinic to adopt. A relationship between embryo metabolism and viability is established and is now being considered together with morphokinetic data to create more robust algorithms for embryo selection. Microfluidic devices have the capacity and potential to be used in human IVF clinics for the routine diagnosis of embryo biomarkers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/humupd/dmu064

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 191

Metadata

Authors
Gardner, D. K., Meseguer, M., Rubio, C., & Treff, N. R.
Venue
Human Reproduction Update
Published
2015-01-06
Volume
21
Issue
6
Pages
727-747
ISSN
  • 1355-4786 (ISSN-L)
  • 1460-2369
OpenAlex
W2151770813
Cited by
191
References
2
FWCI
22.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis of human preimplantation embryo viability. https://app.cochat.ai/papers/10.1093/humupd/dmu064
The paper
Gardner, D. K., Meseguer, M., Rubio, C., & Treff, N. R. (2015). Diagnosis of human preimplantation embryo viability. Human Reproduction Update. https://doi.org/10.1093/humupd/dmu064

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.