Three-dimensional printed prototypes refine the anatomy of post-modified Norwood-1 complex aortic arch obstruction and allow presurgical simulation of the repair
Open accessThe DOI matches its Crossref record.
Abstract
Three-dimensional (3D) printed prototypes of malformed hearts have been used for education, communication, presurgical planning and simulation. We present a case of a 5-month old infant with complex obstruction at the neoaortic to transverse arch and descending aortic junction following the neonatal modified Norwood-1 procedure for hypoplastic left heart syndrome. Digital 3D models were created from a routine 64-slice CT dataset; then life-size solid and magnified hollow models were printed with a 3D printer. The solid model provided further insights into details of the anatomy, whereas the surgical approach and steps of the operation were simulated on the hollow model. Intraoperative assessment confirmed the anatomical accuracy of the 3D models. The operation was performed in accordance with preoperative simulation: sliding autologous flaps achieved relief of the obstruction without additional patching. Knowledge gained from the models fundamentally contributed to successful outcome and improved patient safety. This case study presents an effective use of 3D models in exploring complex spatial relationship at the aortic arch and in simulation-based planning of the operative procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardiac 3D Printing and its Future Directions
Vukicevic, M., Mosadegh, B., Min, J. K., & Little, S. H. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.12.001 · Cited by 535
“A broad range of complex congenital heart anatomies have been reconstructed and 3D printed to enhance surgical planning, including the double-outlet right ventricle (26,42), atrial septal defect (ASD) and ventricular septal defect (18,38,43,44), tetralogy of Fallot (35,45), as well as hypoplastic left heart syndrome (…”
BackgroundApplications of 3D printing in cardiovascular diseases
Giannopoulos, A. A., Mitsouras, D., Yoo, S.-J., Liu, P. P., Chatzizisis, Y. S., & Rybicki, F. J. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.170 · Cited by 421
Hoang, D., Perrault, D., Stevanovic, M., & Ghiassi, A. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.12.18 · Cited by 317
Valverde, I., Gomez-Ciriza, G., Hussain, T., Suarez-Mejias, C., Velasco-Forte, M. N., Byrne, N., Ordoñez, A., Gonzalez-Calle, A., Anderson, D., Hazekamp, M. G., et al. (2017) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezx208 · Cited by 280
Trends in Congenital Heart Disease: The Next Decade
Triedman, J. K., & Newburger, J. W. (2016) · Circulation · doi:10.1161/circulationaha.116.023544 · Cited by 279
Metadata
- Authors
- Kiraly, L., Tofeig, M., Jha, N. K., & Talo, H.
- Venue
- Interactive CardioVascular and Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-11-20
- Volume
- 22
- Issue
- 2
- Pages
- 238-240
- ISSN
- 1569-9285 (ISSN-L)
- 1569-9293
- OpenAlex
- W2257449754
- Cited by
- 102
- References
- 0
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional printed prototypes refine the anatomy of post-modified Norwood-1 complex aortic arch obstruction and allow presurgical simulation of the repair. https://app.cochat.ai/papers/10.1093/icvts/ivv320
- The paper
- Kiraly, L., Tofeig, M., Jha, N. K., & Talo, H. (2016). Three-dimensional printed prototypes refine the anatomy of post-modified Norwood-1 complex aortic arch obstruction and allow presurgical simulation of the repair. Interactive CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivv320
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.