The DOI matches its Crossref record.
The Broad-Spectrum Activity and Efficacy of Catheters Coated with Minocycline and Rifampin
Abstract
The in vitro and in vivo activities of catheters coated with minocycline and rifampin and with chlorhexidine gluconate and silver sulfadiazine were evaluated. When incubated in serum at 37 degrees C, the half-life of the inhibitory activity of catheters coated with minocycline and rifampin was 25 days compared with 3 days for catheters coated with chlorhexidine gluconate and silver sulfadiazine. In a rabbit model, catheters coated with minocycline and rifampin were significantly more efficacious than catheters coated with chlorhexidine and silver sulfadiazine in preventing colonization and infection with Staphylococcus aureus (P < .05). Catheters coated with minocycline and rifampin demonstrated broad-spectrum in vitro inhibitory activity against gram-positive bacteria, gram-negative bacteria, and Candida albicans that was significantly superior to the inhibitory activity of catheters coated with chlorhexidine gluconate and silver sulfadiazine (P < .01). Minocycline and rifampin were also highly efficacious in preventing colonization and infection in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationDental biofilms: difficult therapeutic targets
SOCRANSKY, S. S., & HAFFAJEE, A. D. (2002) · Periodontology 2000 · doi:10.1034/j.1600-0757.2002.280102.x · Cited by 1,273
A Comparison of Two Antimicrobial-Impregnated Central Venous Catheters
Darouiche, R. O., Raad, I. I., Heard, S. O., Thornby, J. I., Wenker, O. C., Gabrielli, A., Berg, J., Khardori, N., Hanna, H., Hachem, R., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901073400101 · Cited by 804
Self-citationDrug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
Metadata
- Authors
- Raad, I., Darouiche, R., Hachem, R., Mansouri, M., & Bodey, G. P.
- Venue
- Journal of Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-02-01
- Volume
- 173
- Issue
- 2
- Pages
- 418-424
- ISSN
- 0022-1899 (ISSN-L)
- 1537-6613
- OpenAlex
- W2142314945
- Cited by
- 249
- References
- 0
- FWCI
- 41.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Broad-Spectrum Activity and Efficacy of Catheters Coated with Minocycline and Rifampin. https://app.cochat.ai/papers/10.1093/infdis/173.2.418
- The paper
- Raad, I., Darouiche, R., Hachem, R., Mansouri, M., & Bodey, G. P. (1996). The Broad-Spectrum Activity and Efficacy of Catheters Coated with Minocycline and Rifampin. Journal of Infectious Diseases. https://doi.org/10.1093/infdis/173.2.418
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.