Efficiency and safety of speech recognition for documentation in the electronic health record
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Objective: To compare the efficiency and safety of using speech recognition (SR) assisted clinical documentation within an electronic health record (EHR) system with use of keyboard and mouse (KBM). Methods: Thirty-five emergency department clinicians undertook randomly allocated clinical documentation tasks using KBM or SR on a commercial EHR system. Tasks were simple or complex, and with or without interruption. Outcome measures included task completion times and observed errors. Errors were classed by their potential for patient harm. Error causes were classified as due to IT system/system integration, user interaction, comprehension, or as typographical. User-related errors could be by either omission or commission. Results: Mean task completion times were 18.11% slower overall when using SR compared to KBM (P = .001), 16.95% slower for simple tasks (P = .050), and 18.40% slower for complex tasks (P = .009). Increased errors were observed with use of SR (KBM 32, SR 138) for both simple (KBM 9, SR 75; P < 0.001) and complex (KBM 23, SR 63; P < 0.001) tasks. Interruptions did not significantly affect task completion times or error rates for either modality. Discussion: For clinical documentation, SR was slower and increased the risk of documentation errors, including errors with the potential to cause clinical harm compared to KBM. Some of the observed increase in errors may be due to suboptimal SR to EHR integration and workflow. Conclusion: Use of SR to drive interactive clinical documentation in the EHR requires careful evaluation. Current generation implementations may require significant development before they are safe and effective. Improving system integration and workflow, as well as SR accuracy and user-focused error correction strategies, may improve SR performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“For example, a recent study of speech recognition for electronic health record documentation found an increased risk of errors, including errors with the potential to cause patient harm.”
From Conversational agents in healthcare: a systematic review (2018) · cites this paper as [51]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736 · cited 1×
“Inter-rater agreement was calculated using Cohen’s kappa.(11) Initial observed agreement was robust across all three categories: (1) 81.”
MethodAchieving Human Parity in Conversational Speech Recognition
Xiong, W., Droppo, J., Huang, X., Seide, F. T. B., Seltzer, M., Stolcke, A., Yu, D., & Zweig, G. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1610.05256 · Cited by 451 · cited 1×
“There continue to be rapid changes in SR technologies; a recent study reports SR systems that now exceed human performance for conversational speech.(16) One recent study examined the potential for EHR transcription using SR together with natural language processing and found potential time and usability benefits for…”
BackgroundCoiera, E. (2015) · CRC Press eBooks · doi:10.1201/b13617 · Cited by 415
Self-citationCommunication loads on clinical staff in the emergency department
Coiera, E. W., Jayasuriya, R. A., Hardy, J., Bannan, A., & Thorpe, M. E. C. (2002) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2002.tb04482.x · Cited by 379
Self-citationThe impact of interruptions on clinical task completion
Westbrook, J. I., Coiera, E., Dunsmuir, W. T. M., Brown, B. M., Kelk, N., Paoloni, R., & Tran, C. (2010) · Quality and Safety in Health Care · doi:10.1136/qshc.2009.039255 · Cited by 341 · cited 1×
“A previous observational study on the impact of interruptions on ED physicians’ task time showed a reduction in task time following interruptions, possibly because physicians hurry to complete tasks after being interrupted when they are under time pressure.(14) Our results suggest that documentation tasks might not be…”
BackgroundSelf-citationToward Human Parity in Conversational Speech Recognition
Xiong, W., Droppo, J., Huang, X., Seide, F., Seltzer, M. L., Stolcke, A., Yu, D., & Zweig, G. (2017) · IEEE/ACM Transactions on Audio, Speech, and Language Processing · doi:10.1109/taslp.2017.2756440 · Cited by 245
Coiera, E., Kocaballi, B., Halamka, J., & Laranjo, L. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0066-9 · Cited by 132
Self-citationElectronic Health Record Interactions through Voice: A Review
Kumah-Crystal, Y., Pirtle, C., Whyte, H., Goode, E., Anders, S., & Lehmann, C. (2018) · Applied Clinical Informatics · doi:10.1055/s-0038-1666844 · Cited by 113
Risks and benefits of speech recognition for clinical documentation: a systematic review
Hodgson, T., & Coiera, E. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv152 · Cited by 102 · cited 4×
“None explored the use of SR for general input and navigation of the EHR, and very few directly compared SR to the use of KBM, the most common input modality for EHR documentation.(3)”
BackgroundMethodResultInfluentialSelf-citation
Research works printed but not linked: 3
- Communications N Speech Recognition Accelerating the Adoption of Electronic Health Records (white paper). Nuance Communications; 2012.
- Food U, Administration D Guidance for the content of premarket submissions for software contained in medical devices. Center Devices Radiol Health. 2005.
- PricewaterhouseCoopers. The Wearable Future. Consumer Intelligence Series. 2014 Accessed October 2014.
Cited by
Conversational agents in healthcare: a systematic review
Laranjo, L., Dunn, A. G., Tong, H. L., Kocaballi, A. B., Chen, J., Bashir, R., Surian, D., Gallego, B., Magrabi, F., Lau, A. Y. S., et al. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy072 · Cited by 1,388
“For example, a recent study of speech recognition for electronic health record documentation found an increased risk of errors, including errors with the potential to cause patient harm.(51) As such, more complex methods of verification of user input (or “grounding”) may be needed, as well as a thorough evaluation of…”
BackgroundSelf-citationShifting machine learning for healthcare from development to deployment and from models to data
Zhang, A., Xing, L., Zou, J., & Wu, J. C. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00898-y · Cited by 420
Speech Technology for Healthcare: Opportunities, Challenges, and State of the Art
Latif, S., Qadir, J., Qayyum, A., Usama, M., & Younis, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.3006860 · Cited by 173
“Furthermore, improved system interoperability and workflow are needed for their successful integration in the clinical setting [119].”
BackgroundCoiera, E., Kocaballi, B., Halamka, J., & Laranjo, L. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0066-9 · Cited by 132
Self-citationKernberg, A., Gold, J. A., & Mohan, V. (2024) · Journal of Medical Internet Research · doi:10.2196/54419 · Cited by 120
“It should be acknowledged that this study only used transcripts, eliminating the confounder of any potential errors introduced by the speech recognition aspect [23,24].”
Electronic Health Record Interactions through Voice: A Review
Kumah-Crystal, Y., Pirtle, C., Whyte, H., Goode, E., Anders, S., & Lehmann, C. (2018) · Applied Clinical Informatics · doi:10.1055/s-0038-1666844 · Cited by 113
Ng, J. J. W., Wang, E., Zhou, X., Zhou, K. X., Goh, C. X. L., Sim, G.-H., Tan, H. K., Goh, S. S. N., & Ng, Q. X. (2025) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-025-03061-0 · Cited by 132
“While Zick et al. [9] and Issenman et al. [12] observed decreased turn-around time (from days to hours or minutes), Hodgson et al. [16] and Blackley et al. [21] found that post-editing often negated potential time gains.”
InfluentialSpeech Recognition for Medical Conversations
Chiu, C.-C., Tripathi, A., Chou, K., Co, C., Jaitly, N., Jaunzeikare, D., Kannan, A., Nguyen, P., Sak, H., Sankar, A., et al. (2018) · Interspeech 2018 · doi:10.21437/interspeech.2018-40 · Cited by 69
Speech recognition for clinical documentation from 1990 to 2018: a systematic review
Blackley, S. V., Huynh, J., Wang, L., Korach, Z., & Zhou, L. (2019) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy179 · Cited by 97
Zhou, L., Blackley, S. V., Kowalski, L., Doan, R., Acker, W. W., Landman, A. B., Kontrient, E., Mack, D., Meteer, M., Bates, D. W., et al. (2018) · JAMA Network Open · doi:10.1001/jamanetworkopen.2018.0530 · Cited by 94
Blackley, S. V., Schubert, V. D., Goss, F. R., Assad, W. A., Garabedian, P. M., & Zhou, L. (2020) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2020.104178 · Cited by 77
Zhang, J., Wu, J., Qiu, Y., Song, A., Li, W., Li, X., & Liu, Y. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106517 · Cited by 69
“Negatively, there are potential recognition errors in the documents, resulting in the turnaround time not being shortened as expected in the scenarios with high accuracy requirements [78].”
Using artificial intelligence to assess clinicians’ communication skills
Ryan, P., Luz, S., Albert, P., Vogel, C., Normand, C., & Elwyn, G. (2019) · BMJ · doi:10.1136/bmj.l161 · Cited by 69
Coiera, E., & Liu, S. (2022) · Cell Reports Medicine · doi:10.1016/j.xcrm.2022.100860 · Cited by 48
Self-citationAndo, K., Okumura, T., Komachi, M., Horiguchi, H., & Matsumoto, Y. (2022) · PLOS Digital Health · doi:10.1371/journal.pdig.0000158 · Cited by 49
Interfacing With the Electronic Health Record (EHR): A Comparative Review of Modes of Documentation
Avendano, J. P., Gallagher, D. O., Hawes, J., Boyle, J., Glasser, L., Aryee, J. N. A., & Katt, B. M. (2022) · Cureus · doi:10.7759/cureus.26330 · Cited by 43
“Numerous errors were attributed to factors relating to the configuration and integration of the SR system [6].”
BackgroundMethodInfluentialElectronic Health Record Data in Cancer Learning Health Systems: Challenges and Opportunities
Post, A. R., Burningham, Z. R., & Halwani, A. S. (2022) · JCO Clinical Cancer Informatics · doi:10.1200/cci.21.00158 · Cited by 33
Dinari, F., Bahaadinbeigy, K., Bassiri, S., Mashouf, E., Bastaminejad, S., & Moulaei, K. (2023) · Health Science Reports · doi:10.1002/hsr2.1330 · Cited by 35
“Hodgson et al., 28 showed that improving system data integration and workflow, along with enhancing accuracy and implementing user ‐ centric error correction strategies, may improve the performance of SR systems.”
BackgroundSaadat, S., Darounkolaei, M. K., Qorbani, M., Hemmat, A., & Hariri, S. (2025) · InfoScience Trends · doi:10.61186/ist.202502.01.01 · Cited by 25
Doctor Chatbot: The EUʼs Regulatory Prescription for Generative Medical AI
Hauglid, M. K., & Mahler, T. (2023) · Oslo Law Review · doi:10.18261/olr.10.1.1 · Cited by 26
Electronic Documentation in Pediatrics: The Rationale and Functionality Requirements
O’Donnell, H. C., Suresh, S., Webber, E. C., Alexander, G. M., Chung, S. L., Hamling, A. M., Kirkendall, E. S., Mann, A. M., Sadeghian, R., Shelov, E. D., et al. (2020) · PEDIATRICS · doi:10.1542/peds.2020-1682 · Cited by 24
A network model of activities in primary care consultations
Kocaballi, A. B., Coiera, E., Tong, H. L., White, S. J., Quiroz, J. C., Rezazadegan, F., Willcock, S., & Laranjo, L. (2019) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocz046 · Cited by 23
Self-citationMachine learning-based speech recognition system for nursing documentation – A pilot study
Lee, T., Li, C.-C., Chou, K., Chung, M., Hsiao, S.-T. S., Guo, S.-L., Hung, L.-Y., & Wu, H. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2023.105213 · Cited by 27
Fatema, M. K. (2025) · doi:10.63125/nvn1yr86 · Cited by 20
Hodgson, T., Magrabi, F., & Coiera, E. W. (2018) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2018.02.011 · Cited by 23
Self-citationPine, K. H., Landon, L. A., Bossen, C., & VanGelder, M. (2021) · Health Information Management Journal · doi:10.1177/18333583211067845 · Cited by 21
“Email: khpine@asu.edu produce, extract and store healthcare data; examples include natural language processing (Soysal et al., 2018), speech recognition technology (Hodgson et al., 2017), taxonomies of data defects (Zhang and Koru, 2020) and data quality feedback tools (Van der Bij et al., 2017).”
BackgroundInnovation in the pediatric electronic health record to realize a more effective platform
Jenssen, B. P., Thayer, J. G., Nekrasova, E., Grundmeier, R. W., & Fiks, A. G. (2021) · Current problems in pediatric and adolescent health care · doi:10.1016/j.cppeds.2021.101109 · Cited by 14
Speech technology in healthcare
Deepa, P., & Khilar, R. (2022) · Measurement Sensors · doi:10.1016/j.measen.2022.100565 · Cited by 20
Peine, A., Gronholz, M., Seidl-Rathkopf, K., Wolfram, T., Hallawa, A., Reitz, A., Celi, L. A., Marx, G., & Märtin, L. (2023) · JMIR Medical Informatics · doi:10.2196/44773 · Cited by 14
“Nevertheless, speech recognition is not well-established; thus, several studies examining the aforementioned technology showed a high error rate with significantly more critical clinical errors [28,35].”
BackgroundResultChen, J., Lyell, D., Laranjo, L., & Magrabi, F. (2020) · Journal of Medical Internet Research · doi:10.2196/14827 · Cited by 12
Self-citationAbdulrahman, A., & Richards, D. (2021) · Multimodal Technologies and Interaction · doi:10.3390/mti5090056 · Cited by 11
Speech Recognition Technology and Documentation Efficiency
Shour, A. R., Anguzu, R., & Onitilo, A. A. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2025.1526 · Cited by 11
Firdaus, M. (2019) · Jurnal Administrasi Rumah Sakit Indonesia · doi:10.7454/arsi.v6i1.2880 · Cited by 19
Electronic Documentation in Pediatrics: The Rationale and Functionality Requirements
O’Donnell, H. C., Suresh, S., Webber, E. C., Alexander, G. M., Chung, S. L., Hamling, A. M., Kirkendall, E. S., Mann, A. M., Sadeghian, R., Shelov, E. D., et al. (2020) · PEDIATRICS · doi:10.1542/peds.2020-1684 · Cited by 14
El Morr, C. (2019) · International Journal of Extreme Automation and Connectivity in Healthcare · doi:10.4018/ijeach.2019010102 · Cited by 10
Chun, S.-J., Park, J., Ryu, H., & Jang, B. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2023.105112 · Cited by 10
Medical Malpractice Trends: Errors in Automated Speech Recognition
Topaz, M., Schaffer, A. C., Lai, K. H., Korach, Z. T., Einbinder, J. S., & Zhou, L. (2018) · Journal of Medical Systems · doi:10.1007/s10916-018-1011-9 · Cited by 10
Apple Intelligence in neurosurgery
Mohamed, A. A., & Lucke-Wold, B. P. (2024) · Neurosurgical Review · doi:10.1007/s10143-024-02568-w · Cited by 10
Artificial Intelligence: Help or Hindrance for Family Physicians?
Irfan, F. (2020) · Pakistan Journal of Medical Sciences · doi:10.12669/pjms.37.1.3351 · Cited by 15
Woo, M., Mishra, P., Lin, J., Kar, S., Deas, N., Linduff, C., Niu, S., Yang, Y., McClendon, J. L., Smith, D. H., et al. (2021) · JMIR mhealth and uhealth · doi:10.2196/32301 · Cited by 8
“Given the necessity of seeking solutions that will not degrade the clinical workflow, technology solutions using automatic speech recognition (ASR) have been explored for hands-free clinical documentation [20-23].”
BackgroundAtiku, S. O., Owolanke, K., & Olakotan, O. O. (2026) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.70460 · Cited by 7
“…such as emergency medicine and mental health services, systematic misrecognition of subtle language may amplify patient safety vulnerabilities [27, 38, 50], a concern echoed by patient safety bodies that caution speech recognition– related documentation errors can introduce downstream harm…”
InfluentialPhysician perceptions of documentation methods in electronic health records
McAmis, N. E., Dunn, A. S., Feinn, R., Bernard, A. W., & Trost, M. J. (2021) · Health Informatics Journal · doi:10.1177/1460458221989399 · Cited by 7
“9,10 Electronic transcription also has a faster turnaround time than human transcription services.”
BackgroundHodgson, T., Magrabi, F., & Coiera, E. W. (2018) · Applied Clinical Informatics · doi:10.1055/s-0038-1649509 · Cited by 9
Self-citationAsynchronous Speech Recognition Affects Physician Editing of Notes
Lybarger, K., Mari Ostendorf, E., Riskin, E. A., Payne, T. H., White, A. A., & Yetişgen, M. (2018) · Applied Clinical Informatics · doi:10.1055/s-0038-1673417 · Cited by 6
Künstliche Intelligenz: Herausforderungen und Nutzen in der Intensivmedizin
Märtin, L., Peine, A., Gronholz, M., Marx, G., & Bickenbach, J. (2022) · AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie · doi:10.1055/a-1423-8006 · Cited by 8
Automatic Speech Recognition System to Record Progress Notes in a Mobile EHR: A Pilot Study
Vargas, C. P., Gaiera, A., Brandán, A., Renato, A. C., Benítez, S., & Luna, D. R. (2024) · Studies in health technology and informatics · doi:10.3233/shti230940 · Cited by 5
Green, K., Asthana, S., Ponce, O. J., Downey, J., & Watson, J. (2025) · JMIR Research Protocols · doi:10.2196/68511 · Cited by 4
“…summary notes are being developed to combine diagnostic decision support systems to highlight the most relevant clinical information [55], developing intelligent methods to structure, organize, and improve the accuracy of summaries [56] and reduce critical fact omissions and hallucinations [57].”
Systematic Evaluation and Enhancement of Speech Recognition in Operational Medical Environments
Kar, S., Mishra, P., Lin, J., Woo, M., Deas, N., Linduff, C., Niu, S., Yang, Y., McClendon, J. L., Smith, D. H., et al. (2021) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn52387.2021.9533607 · Cited by 8
“the technology-based solutions that have been developed thus far, have not reliably addressed these needs [4].”
BackgroundThe Holy grail of healthcare analytics: what it takes to get there?
Gowda, N. R., Satpathy, S., Singh, A. R., & Behera, S. (2022) · BMJ Leader · doi:10.1136/leader-2021-000527 · Cited by 4
Choi, D. H., Hong, K. J., Shin, S. D., Kim, S., Chung, M., Kim, K. H., Song, K. J., Cho, M., Yoon, D., & Lee, J. (2023) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2023.09.044 · Cited by 2
Cahill, M. M., O’Shaughnessy, F., Boland, F. M., Áinle, F. N., Donnelly, J. C., Cullinan, S., & Cleary, B. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106367 · Cited by 2
Lipinski, M., Smith, E., & Vaillancourt, C. (2026) · Canadian Journal of Emergency Medicine · doi:10.1007/s43678-026-01141-2 · Cited by 2
“Two of those studies evaluated speech recognition only (not an ambient AI scribe) [12, 13] and the third was the evaluation of an AI scribe system itself without explicitly assessing efficiency [14].”
Szplit, D., Czyżewski, A., Graff, B., Szyndler, A., Pałczyński, P., Siemiński, M., Glaner, N., Stefaniak, T., Bogdan, J., Słomińska, K., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-50490-6 · Cited by 2
“This is particularly important for speech-driven documentation tools, where prior work has highlighted both the potential benefits and risks of speech recognition for clinical documentation, including its impact on efficiency, safety and error patterns 47,48 .”
Xiao, N., Li, H., Chen, L., Liu, S., Xiang, Q., & Wang, P. (2026) · Frontiers in Psychology · doi:10.3389/fpsyg.2026.1840884 · Cited by 3
“…depends not only on whether it saves time, but also on whether clinicians regard the output as clinically trustworthy, communicatively appropriate, and sufficiently aligned with their own documentation style and professional judgment (Fraile Navarro et al., 2025; Hodgson et al., 2017).”
Minerbi, A., Besemann, M., Kari, T., Gentile, C., & Gupta, G. (2020) · Military Medicine · doi:10.1093/milmed/usz374 · Cited by 2
The Unintended Irregularities of Automatic Speech Recognition
Vase, S. (2020) · Proceedings of the World Congress on Electrical Engineering and Computer Systems and Science · doi:10.11159/mhci20.103 · Cited by 2
Morr, C. E. (2021) · IGI Global eBooks · doi:10.4018/978-1-7998-8544-3.ch022 · Cited by 2
Usability Test for a Smart Glass–Based Application to Support Nurses' Hospital Admission Tasks
Kagawa, S., & Iijima, S. (2026) · CIN Computers Informatics Nursing · doi:10.1097/cin.0000000000001295 · Cited by 2
Challenges to Healthcare Professionals Regarding the Use of Electronic Health Records in PHCs
Alonazi, E. (2025) · Journal of Clinical Practice and Medical Research · doi:10.59324/jcpmr.2025.1(3).05 · Cited by 1
Emergency Department of the New Era
Guerrero, A., Barnes, D. K., & Pattison, H. M. (2019) · Springer eBooks · doi:10.1007/978-3-030-01394-3_21 · Cited by 1
How Workarounds Occur in Relation to Automatic Speech Recognition at Danish Hospitals
Vase, S. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-78468-3_31 · Cited by 2
Development of Clinical Pharmaceutical Services via Artificial Intelligence Adaptation
Sato, H. (2022) · YAKUGAKU ZASSHI · doi:10.1248/yakushi.21-00178-4 · Cited by 2
Künstliche Intelligenz: Herausforderungen und Nutzen in der Intensivmedizin
Märtin, L., Peine, A., Gronholz, M., Marx, G., & Bickenbach, J. (2024) · intensiv · doi:10.1055/a-2240-2823
Maryati, W., Hartono, H., & Febrinasari, R. P. (2024) · Proceeding of International Conference on Science Health And Technology · doi:10.47701/icohetech.v5i1.4252
“For example, the use of EMR with voice recognition to assist clinical documentation actually makes the doctor's work slower and increases the risk of errors (Hodgson et al., 2017).”
Multimodal journaling as engagement tool for parents of premature babies
Boda, P., & Vetek, A. (2025) · Informatics for Health and Social Care · doi:10.1080/17538157.2025.2585308
“…37 parsing unstructured reports, clinical documen-tations such as doctors’ spoken entries in electronic medical or health records (EMR, EHR), 38,39 using dictation to prepare pathology and radiology reports, diagnosis based on patient utterances, 40 etc. Success rates are not uniformly high in…”
Shah, J., Iyer, A., Patel, R., Manji, S., Khakhar, Z., Yunis, A. A., Chandani, A., & Ali, S. K. (2026) · Journal of Kenya Assocation of Physicians · doi:10.4314/jkap.v8i1.4
Karbalaie, A., Seoane, F., & Abtahi, F. (2026) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2026.1829902 · Cited by 1
Sasikala, D., Sathya, S. S., Niranjan Kumar, D., & Vignesh, S. (2026) · Journal of Electronics Electromedical Engineering and Medical Informatics · doi:10.35882/jeeemi.v8i4.1778
“However, general-purpose ASR systems trained on standard English benchmarks are not reliable for clinical environments [13][14][15].”
Influential
Metadata
- Authors
- Hodgson, T., Magrabi, F., & Coiera, E.
- Affiliations
- Macquarie University (AU)
- Corresponding author
- Hodgson, Tobias
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-07-27
- Volume
- 24
- Issue
- 6
- Pages
- 1127-1133
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- PMC
- PMC7651984
- OpenAlex
- W2740281359
- Cited by
- 63
- References
- 18
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 4 · 2023: 7 · 2022: 9 · 2021: 8 · 2020: 8 · 2019: 4 · 2018: 11 · 2017: 1
- FWCI
- 9.01
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of the American Medical Informatics Association (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Funders
- National Health and Medical Research Council (APP1032664)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Nursing › Research and Theory › Nursing Diagnosis and Documentation
- Health Sciences › Health Professions › Health Information Management › Medical Coding and Health Information
- Keywords
- speech recognition, clinical documentation, electronic health records, keyboard and mouse input, documentation errors, task completion time, emergency department clinicians, electronic health record integration, workflow, patient safety
- MeSH terms
- Documentation, Efficiency, Emergency Service, Hospital, Humans, Random Allocation, User-Computer Interface, Computer Peripherals, Medical Errors, Speech Recognition Software, Electronic Health Records
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.


