The DOI matches its Crossref record.
Sample Preparation for Chromatography of Amino Acids: Acid Hydrolysis of Proteins
Abstract
A number of variations were evaluated in the techniques and procedures of the classical 6N hydrochloric acid, 110°C, 24 h hydrolysis of protein. Variations included the use of glass tubes with Teflon-lined screw caps as the hydrolysis vessel, high-temperature short-time hydrolysis, performic acid oxidation of cystine and methionine, multiple hydrolysis times at 145°C, and interlaboratory preparation of hydrolysates. A diverse sample set used in the study included a range of protein-containing matrices, and automated ionexchange chromatography was used for the amino acid analysis. Results show that for hydrolysis in glass tubes with Teflon-lined screw caps at 110°C for 24 h, recoveries of amino acids were in good agreement with recoveries by classical hydrolysis in sealed glass ampoules at reduced pressure. Recoveries from a higher temperature hydrolysis, i.e., 145°C for 4 h and using sealed ampoules, were also in agreement with 110°C, 24 h, sealed ampoule results; the former procedure yielded increased isoleucine and valine and decreased serine and threonine values. Glass tubes with Teflon-lined screw caps for hydrolysis were found to be a practical and convenient alternative to sealed glass ampoules; the improved precision with the former was probably due to the simplicity of the method. The average recovery of cystine from a wide range of matrices without the use of performic acid was 55.5% compared with results obtained with performic acid oxidation. Similarly, methionine is preferably analyzed as methionine sulfone. Interlaboratory evaluation of 145°C, 4 h hydrolysis, in which one laboratory used sealed ampoules and the other laboratory used Teflon-lined screw-cap tubes, demonstrated excellent agreement of amino acid values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nutritional evaluation of some subtropical red and green seaweeds
Wong, K. H., & Cheung, P. C. K. (2000) · Food Chemistry · doi:10.1016/s0308-8146(00)00175-8 · Cited by 435
The cornell net carbohydrate and protein system: updates to the model and evaluation of version 6.5
Van Amburgh, M. E., Collao-Saenz, E. A., Higgs, R. J., Ross, D. A., Recktenwald, E. B., Raffrenato, E., Chase, L. E., Overton, T. R., Mills, J. K., & Foskolos, A. (2015) · Journal of Dairy Science · doi:10.3168/jds.2015-9378 · Cited by 329
He, R., Girgih, A. T., Malomo, S. A., Ju, X., & Aluko, R. E. (2013) · Journal of Functional Foods · doi:10.1016/j.jff.2012.10.008 · Cited by 327
Ajibola, C. F., Fashakin, J. B., Fagbemi, T. N., & Aluko, R. E. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12106685 · Cited by 307
Structural and Antihypertensive Properties of Enzymatic Hemp Seed Protein Hydrolysates
Malomo, S., Onuh, J., Girgih, A., & Aluko, R. (2015) · Nutrients · doi:10.3390/nu7095358 · Cited by 137
Metadata
- Authors
- Gehrke, C. W., Wall, L. L., Absheer, J. S., Kaiser, F. E., & Zumwalt, R. W.
- Venue
- Journal of AOAC INTERNATIONAL
- Publisher
- Oxford University Press (OUP)
- Published
- 1985-09-01
- Volume
- 68
- Issue
- 5
- Pages
- 811-821
- ISSN
- 0004-5756 (ISSN-L)
- OpenAlex
- W3008273028
- Cited by
- 223
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sample Preparation for Chromatography of Amino Acids: Acid Hydrolysis of Proteins. https://app.cochat.ai/papers/10.1093/jaoac/68.5.811
- The paper
- Gehrke, C. W., Wall, L. L., Absheer, J. S., Kaiser, F. E., & Zumwalt, R. W. (1985). Sample Preparation for Chromatography of Amino Acids: Acid Hydrolysis of Proteins. Journal of AOAC INTERNATIONAL. https://doi.org/10.1093/jaoac/68.5.811
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.