Kjeldahl Method for Determination of Total Nitrogen Content of Milk: Collaborative Study
The DOI matches its Crossref record.
Abstract
A macro-KJeldahl procedure using a copper catalyst for determination of milk total nitrogen was developed for both traditional and block dlgestor/steam distiller equipment, and the performance was evaluated by collaborative study. In the first trial of the collaborative study, 9 pairs of blind duplicate milk samples were analyzed for total nitrogen and total nitrogen was converted to "protein" by using a factor of 6.38. Protein content of milk samples ranged from 3.086 to 3.610%. In the first trial, sR and R values for the block dlgestors were influenced significantly by protein concentration; 8R and R values were not Influenced by protein concentration for traditional equipment. It was hypothesized that total digestion time for some block dlgestors In the first trial was not sufficient for high protein milk samples. Thus, a second trial was undertaken with boiling time after clearing Increased by 0.5 h. In the second trial, none of the parameters for reproducibility with either type of equipment were Influenced by protein concentration. It was concluded that laboratory-to-laboratory differences In line voltage may require different total digestion times in different laboratories, particularly those using block dlgestors. The Kjeldahl method using a copper catalyst and either traditional or block digestor equipment for determination of milk total nitrogen has been adopted official first action by AOAC to replace method 920.105.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sáez-Plaza, P., Navas, M. J., Wybraniec, S., Michałowski, T., & Asuero, A. G. (2013) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2012.751787 · Cited by 523
Total Protein Methods and Their Potential Utility to Reduce the Risk of Food Protein Adulteration
Moore, J. C., DeVries, J. W., Lipp, M., Griffiths, J. C., & Abernethy, D. R. (2010) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/j.1541-4337.2010.00114.x · Cited by 249
Kuhfeld, R. F., Eshpari, H., Kim, B. J., Kuhfeld, M. R., Atamer, Z., & Dallas, D. C. (2024) · Food Chemistry · doi:10.1016/j.foodchem.2023.138111 · Cited by 23
Influence of Dietary Spices on Protein Digestibility and Absorption in Experimental Rats
Prakash, U. N. S., & Srinivasan, K. (2013) · Food Digestion · doi:10.1007/s13228-013-0031-7 · Cited by 4
Metadata
- Authors
- Barbano, D. M., Clark, J. L., Dunham, C. E., & Flemin, R. J.
- Venue
- Journal of AOAC INTERNATIONAL
- Publisher
- Oxford University Press (OUP)
- Published
- 1990-11-01
- Volume
- 73
- Issue
- 6
- Pages
- 849-859
- ISSN
- 0004-5756 (ISSN-L)
- OpenAlex
- W27595397
- Cited by
- 165
- References
- 0
- FWCI
- 7.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kjeldahl Method for Determination of Total Nitrogen Content of Milk: Collaborative Study. https://app.cochat.ai/papers/10.1093/jaoac/73.6.849
- The paper
- Barbano, D. M., Clark, J. L., Dunham, C. E., & Flemin, R. J. (1990). Kjeldahl Method for Determination of Total Nitrogen Content of Milk: Collaborative Study. Journal of AOAC INTERNATIONAL. https://doi.org/10.1093/jaoac/73.6.849
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.