CoChat

Correlation of Saliva Codeine Concentrations with Plasma Concentrations after Oral Codeine Administration

O'Neal, C. L., Crouch, D. J., Rollins, D. E., Fatah, A., Cheever, M. L. · 1999 · Journal of Analytical Toxicology
Cited by 66

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A clinical study was designed to determine if there was a predictable relationship between saliva and plasma codeine concentrations. Drug-free volunteers (n = 17) were administered a 30-mg dose of liquid codeine phosphate. Plasma and saliva specimens were collected at various times for 24 h after administration. Plasma and saliva were analyzed for codeine and morphine by positive-ion chemical ionization gas chromatography-mass spectrometry. The plasma codeine concentrations peaked between 30 min and 2 h after administration and ranged from 19 to 74 ng/mL with a mean of 46 ng/mL. Despite decontamination procedures, elevated saliva codeine concentrations were detected at the early collection times because of contamination of the oral cavity from the liquid codeine. Codeine concentrations in the 15 min specimens ranged from 690 ng/mL to over 15,000 ng/mL. After the initial 2-h period, the mean codeine saliva concentrations declined at a rate similar to that observed in the plasma, but remained 3 to 4 times greater than the plasma concentrations. During the elimination phase, half-life estimates for codeine in plasma and saliva were found to be equivalent, 2.6 and 2.9 h, respectively. However, the area under the curve (AUC) estimate for codeine in saliva was 13 times greater than the plasma AUC. Contamination of the saliva resulted in elevated saliva/plasma (S/P) concentration ratios for the first 1 to 2 h after drug administration. Consequently, S/P ratios in specimens collected in the first 15 to 30 min ranged from 75 to 2580. However, after the absorption phase, a significant correlation between saliva and plasma concentrations was observed (r = 0.809, p < 0.05) and mean S/P ratios remained constant (mean = 3.7). Although small changes in saliva pH were predicted to produce profound changes in the S/P ratios for codeine, this was not observed in the current study. Therefore, saliva codeine concentrations could be used to estimate plasma concentrations through the use of the S/P ratio once the oral contamination has been eliminated. However, these estimates should be made cautiously. One must ensure that oral contamination is not a factor. Also, as with blood-drug concentrations, considerable intersubject variability was observed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jat/23.6.452

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
O'Neal, C. L., Crouch, D. J., Rollins, D. E., Fatah, A., & Cheever, M. L.
Venue
Journal of Analytical Toxicology
Published
1999-10-01
Volume
23
Issue
6
Pages
452-459
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W2167434687
Cited by
66
References
1
FWCI
4.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.