CoChat

Urinary Elimination of Cocaine Metabolites in Chronic Cocaine Users during Cessation

Preston, K. L., Epstein, D. H., Cone, E. J., Wtsadik, A. T., Huestis, M. A., Moolchan, E. T. · 2002 · Journal of Analytical Toxicology
Cited by 72

The DOI matches its Crossref record.

Abstract

We previously showed that chronic cocaine use by active illicit users produced a longer plasma half-life than expected based on acute low-dose cocaine studies. Here we report urinary excretion patterns of cocaine metabolites as benzoylecgonine (BE) equivalents from 18 of the same individuals, housed for up to 14 days on a closed research unit. In addition, we evaluated whether creatinine normalization of BE equivalents increased mean detection time and reduced mean within-subject variability. All urine voids (N = 953) were individually assayed; BE equivalents were determined semi-quantitatively by FPIA. Compared to concentration in first void after admission, BE equivalents decreased to approximately 33%, 8%, and 4% at 24, 48, and 72 h, respectively. Mean +/- SD (range) time to first negative specimen (BE equivalents < 300 ng/mL) was 43.6 +/- 17.1 (16-66) h. BE equivalents fluctuated considerably across successive specimens; 69% of participants tested positive at least once after testing negative, and the mean time to last positive specimen was 57.5 +/- 31.6 (11-147) h after the first specimen. Thus, mean cocaine metabolite detection times were consistent with prolonged elimination, with 63% of participants testing positive longer than the expected 48-h window of detection after admission to the unit. Mean time to last positive after last use of cocaine, known by self-report only, was approximately 81 +/- 34 (34-162) h. Creatinine normalization, with the cut-off of 300 ng BE equivalents/mg creatinine, increased detection time: mean time to first negative specimen was 54.8 +/- 20.7 (20-100) h, and mean time to last positive specimen was 88.4 +/- 51.0 (35.6-235) h. Compared with the concentration in the first void after admission, BE equivalents/creatinine decreased to approximately 56%, 6%, and 5% at 24, 48, and 72 h. However, creatinine normalization did not reduce the fluctuation of BE equivalents across successive specimens. Thus, creatinine normalized values may be useful when the goal is to maximize the probability or duration of cocaine metabolite detection, but may be less useful in determining whether an individual has used cocaine since a previous specimen collection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jat/26.7.393

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Preston, K. L., Epstein, D. H., Cone, E. J., Wtsadik, A. T., Huestis, M. A., & Moolchan, E. T.
Venue
Journal of Analytical Toxicology
Published
2002-10-01
Volume
26
Issue
7
Pages
393-400
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W2142636775
Cited by
72
References
0
FWCI
2.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.