CoChat

Sensitivity, Specificity, and Efficiency in Detecting Opiates in Oral Fluid with the Cozart(R) Opiate Microplate EIA and GC-MS Following Controlled Codeine Administration

Barnes, A. J., Kim, I., Schepers, R., Moolchan, E. T., Wilson, L., Cooper, G., Reid, C., Hand, C., Huestis, M. A. · 2003 · Journal of Analytical Toxicology
Cited by 43

The DOI matches its Crossref record.

Abstract

Oral fluid specimens (N = 1406) were collected from 19 subjects prior to and up to 72 h following controlled administration of oral codeine. Volunteers provided informed consent to participate in this National Institute on Drug Abuse Institutional Review Board-approved protocol. A modification of Cozart Microplate Opiate EIA Oral Fluid Kit (Opiate ELISA), employing codeine calibrators, was used for semiquantitative analysis of opiates, followed by gas chromatography-mass spectrometry (GC-MS) for the confirmation and quantitation of codeine, norcodeine, morphine, and normorphine in oral fluid. GC-MS limits of detection and quantitation were 2.5 microg/L for all analytes. The Substance Abuse and Mental Health Services Administration (SAMHSA) has proposed a 40-microg/L opiate screening and a 40-microg/L morphine or codeine confirmation cutoff for the detection of opiate use. Oral fluid opiate screening and confirmation cutoffs of 30 micro g/L are in use in the U.K. Utilizing 2.5-, 20-, 30-, and 40-microg/L GC-MS cutoffs, 26%, 20%, 19%, and 18% of the oral fluid specimens were positive for codeine or one of its metabolites. Six Opiate ELISA/confirmation cutoff criteria (2.5/2.5, 10/2.5, 20/20, 30/20, 30/30, and 40/40 microg/L) were evaluated. Calculations for Opiate ELISA sensitivity, specificity, and efficiency were determined from the number of true-positive, true-negative, false-positive, and false-negative results at each screening/confirmation cutoff. Sensitivity, specificity, and efficiency for the lowest cutoff were 91.5%, 88.6%, and 89.3%. Application of the cutoff currently used in the U.K. yielded sensitivity, specificity, and efficiency results of 79.7%, 99.0%, and 95.4% and similar results of 76.7%, 99.1%, and 95.1% when applying the SAMHSA criteria. These data indicate that the Opiate ELISA efficiently detects oral codeine use. In addition, the data, collected following controlled oral codeine administration, may aid in the interpretation of opiate oral fluid test results and in the selection of appropriate oral fluid screening and confirmation cutoffs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jat/27.7.402

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 43

Metadata

Authors
Barnes, A. J., Kim, I., Schepers, R., Moolchan, E. T., Wilson, L., Cooper, G., Reid, C., Hand, C., & Huestis, M. A.
Venue
Journal of Analytical Toxicology
Published
2003-10-01
Volume
27
Issue
7
Pages
402-406
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W2172118831
Cited by
43
References
0
FWCI
6.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitivity, Specificity, and Efficiency in Detecting Opiates in Oral Fluid with the Cozart(R) Opiate Microplate EIA and GC-MS Following Controlled Codeine Administration. https://app.cochat.ai/papers/10.1093/jat/27.7.402
The paper
Barnes, A. J., Kim, I., Schepers, R., Moolchan, E. T., Wilson, L., Cooper, G., Reid, C., Hand, C., & Huestis, M. A. (2003). Sensitivity, Specificity, and Efficiency in Detecting Opiates in Oral Fluid with the Cozart(R) Opiate Microplate EIA and GC-MS Following Controlled Codeine Administration. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/27.7.402

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.