Simultaneous Analysis of 14 Benzodiazepines in Oral Fluid by Solid-Phase Extraction and LC-MS-MS
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A simple and rapid procedure for the simultaneous screening of 14 benzodiazepines in oral fluid is presented. The procedure involves a solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS-MS). The target compounds include diazepam, oxazepam, temazepam, nordiazepam, lorazepam, chlordiazepoxide, alprazolam, alpha-hydroxyalprazolam, desalkylflurazepam, hydroxyethylflurazepam, clonazepam, 7-aminoclonazepam, flunitrazepam, and 7-aminoflunitrazepam. Oral fluid was obtained using a simple device that collects approximately 0.4 mL of oral fluid and dilutes it with 0.8 mL of preservative. The oral fluid sample preparation involves a solid-phase extraction on a Varian Bond Elut cartridge. Quantitation was performed by LC-MS-MS using nordiazepam-d(5) as the internal standard. The extraction efficiency exceeded 83% for all compounds except for 7-aminoclonazepam, which had a recovery of 55%. The limits of quantitation ranged from 0.1 ng/mL to 1.0 ng/mL in the multiple reaction monitoring mode. This method was used to confirm 41 patients that screened positive using the OraSure Technologies Benzodiazepine Intercept MICRO-PLATE Enzyme Immunoassay kit. All screened-positive patients were positive for at least one of the analyzed benzodiazepines, thus showing that this method is suitable for confirmation of the Intercept Benzodiazepine assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the Rational Use of Benzodiazepines: When and What to Use
Ashton, H. (1994) · Drugs · doi:10.2165/00003495-199448010-00004 · Cited by 593
Urinalysis of α-Hydroxyalprazolam, α-Hydroxytriazolam, and Other Benzodiazepine Compounds by GC/EIMS
Dickson, P. H., Markus, W., McKernan, J., & Nipper, H. C. (1992) · Journal of Analytical Toxicology · doi:10.1093/jat/16.2.67 · Cited by 29
Cited by
Oral fluid testing for drugs of abuse
Bosker, W. M., & Huestis, M. A. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.108670 · Cited by 378
Oral fluid drug testing: analytical approaches, issues and interpretation of results
Desrosiers, N. A., & Huestis, M. A. (2019) · Journal of Analytical Toxicology · doi:10.1093/jat/bkz048 · Cited by 123
Temte, V., Kjeldstadli, K., Bruun, L. D., Birdal, M., Bachs, L., Karinen, R., Middelkoop, G., Øiestad, E., & Høiseth, G. (2019) · Journal of Analytical Toxicology · doi:10.1093/jat/bky062 · Cited by 15
Metadata
- Authors
- Ngwa, G., Fritch, D., Blum, K., & Newland, G.
- Venue
- Journal of Analytical Toxicology
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-09-01
- Volume
- 31
- Issue
- 7
- Pages
- 369-376
- ISSN
- 0146-4760 (ISSN-L)
- 1945-2403
- OpenAlex
- W2129035781
- Cited by
- 43
- References
- 2
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Analysis of 14 Benzodiazepines in Oral Fluid by Solid-Phase Extraction and LC-MS-MS. https://app.cochat.ai/papers/10.1093/jat/31.7.369
- The paper
- Ngwa, G., Fritch, D., Blum, K., & Newland, G. (2007). Simultaneous Analysis of 14 Benzodiazepines in Oral Fluid by Solid-Phase Extraction and LC-MS-MS. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/31.7.369
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.