Validation of Analysis of Amphetamines, Opiates, Phencyclidine, Cocaine, and Benzoylecgonine in Oral Fluids by Liquid Chromatography-Tandem Mass Spectrometry
The DOI matches its Crossref record.
Abstract
The aim of the present study was to develop and validate a method for the detection and quantitation of drugs of abuse in oral fluids. Fortified oral fluid samples (made in-house) and samples from donors collected with Quantasil oral fluid collection kits from Immunalysis were screened on an Olympus 5400 using reagents purchased from Immunalysis. Amphetamines (AMPs), opiates, phencyclidine (PCP), and cocaine and its metabolite benzoylecgonine (BE) in oral fluids were quantitated by an Applied Biosystems 3200 QTRAP liquid chromatograph-tandem mass spectrometer (LC-MS-MS). AMPs, opiates, PCP, cocaine, and BE were extracted from samples using liquid-liquid or solid-phase extractions and the extracts were separated on a Shimadzu high-performance liquid chromatograph prior to the MS-MS analysis. For each drug, two multiple reaction mode transitions were monitored using positive electrospray ionization coupled to an MS-MS detector. Corresponding d3, d5, d6, and d11 internal standards were used to quantitate the results. The limit of detection/quantitation for AMPs, opiates, PCP, cocaine, and its metabolite BE were 10, 10, 2, 2, and 2 ng/mL of oral fluid, respectively, on a signal-to-noise ratio > 4. This corresponded to 25, 25, 5, 5, and 5 pg on column. The method was verified by participating in the North America Oral Fluid Proficiency Testing administered by Research Triangle Institute and by analyzing real samples from donors. In conclusion, LC-MS-MS provided a simple way to analyze and quantitate drugs of abuse in oral fluids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oral fluid testing for drugs of abuse
Bosker, W. M., & Huestis, M. A. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.108670 · Cited by 378
Oral fluid drug testing: analytical approaches, issues and interpretation of results
Desrosiers, N. A., & Huestis, M. A. (2019) · Journal of Analytical Toxicology · doi:10.1093/jat/bkz048 · Cited by 123
Stout, P. R., Bynum, N. D., Mitchell, J. M., Baylor, M. R., & Ropero-Miller, J. D. (2009) · Journal of Analytical Toxicology · doi:10.1093/jat/33.8.398 · Cited by 29
Metadata
- Authors
- Kala, S. V., Harris, S. E., Freijo, T. D., & Gerlich, S.
- Venue
- Journal of Analytical Toxicology
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-10-01
- Volume
- 32
- Issue
- 8
- Pages
- 605-611
- ISSN
- 0146-4760 (ISSN-L)
- 1945-2403
- OpenAlex
- W2111935840
- Cited by
- 48
- References
- 0
- FWCI
- 11.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of Analysis of Amphetamines, Opiates, Phencyclidine, Cocaine, and Benzoylecgonine in Oral Fluids by Liquid Chromatography-Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1093/jat/32.8.605
- The paper
- Kala, S. V., Harris, S. E., Freijo, T. D., & Gerlich, S. (2008). Validation of Analysis of Amphetamines, Opiates, Phencyclidine, Cocaine, and Benzoylecgonine in Oral Fluids by Liquid Chromatography-Tandem Mass Spectrometry. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/32.8.605
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.