The DOI matches its Crossref record.
Fluorescence Polarization Immunoassay for the Determination of Therapeutic Drug Levels in Human Plasma
Abstract
Fluorescence polarization immunoassay (FPIA) is a technique which has been known for a number of years, but despite its many advantages, its has not seen clinical utility. The main reason for this is the lack of simple, rapid, high performance instrumentation suitable for use in a clinical laboratory. This problem has been addressed in this laboratory and an instrument has been developed which meets these needs. The solutions of the two other problems associated with the technique (i.e. non-specific binding of tracer to serum proteins and the intrinsic fluorescence of serum) have also been accomplished. Assays for a variety of therapeutic drugs including gentamicin, theophylline, phenytoin, and phenobarbital have been developed and shown to correlate well with a number of reference method. The assays have been totally automated with a concomitant increase in speed and ease of use and a significant improvement in performance over the manual system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magariños, A. M., McEwen, B. S., Flügge, G., & Fuchs, E. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-10-03534.1996 · Cited by 864
A rapid diffusion immunoassay in a T-sensor
Hatch, A., Kamholz, A. E., Hawkins, K. R., Munson, M. S., Schilling, E. A., Weigl, B. H., & Yager, P. (2001) · Nature Biotechnology · doi:10.1038/88135 · Cited by 383
Lorazepam and diazepam effects on memory acquisition in priming tasks
Vidailhet, P., Danion, J.-M., Kauffmann-Muller, F., Grangé, D., Giersch, A., Van Der Linden, M., & Imbs, J.-L. (1994) · Psychopharmacology · doi:10.1007/bf02245083 · Cited by 96
Serralta, A., Barcia, J. A., Ortiz, P., Durán, C., Hernández, M. E., & Alós, M. (2006) · Epilepsy Research · doi:10.1016/j.eplepsyres.2006.02.003 · Cited by 33
Metadata
- Authors
- Jolley, M. E.
- Venue
- Journal of Analytical Toxicology
- Publisher
- Oxford University Press (OUP)
- Published
- 1981-09-01
- Volume
- 5
- Issue
- 5
- Pages
- 236-240
- ISSN
- 0146-4760 (ISSN-L)
- 1945-2403
- OpenAlex
- W2152821330
- Cited by
- 195
- References
- 0
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence Polarization Immunoassay for the Determination of Therapeutic Drug Levels in Human Plasma. https://app.cochat.ai/papers/10.1093/jat/5.5.236
- The paper
- Jolley, M. E. (1981). Fluorescence Polarization Immunoassay for the Determination of Therapeutic Drug Levels in Human Plasma. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/5.5.236
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.