Detection of 30 Fentanyl Analogs by Commercial Immunoassay Kits
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Health-care workers, laboratorians and overdose prevention centers rely on commercial immunoassays to detect the presence of fentanyl; however, the cross-reactivity of fentanyl analogs with these kits is largely unknown. To address this, we conducted a pilot study evaluating the detection of 30 fentanyl analogs and metabolites by 19 commercially available kits (9 lateral flow assays, 7 heterogeneous immunoassays and 3 homogenous immunoassays). The analogs selected for analysis were compiled from the Drug Enforcement Administration and National Forensic Laboratory Information System reports from 2015 to 2018. In general, the immunoassays tested were able to detect their intended fentanyl analog and some closely related analogs, but more structurally diverse analogs, including 4-methoxy-butyryl fentanyl and 3-methylfentanyl, were not well detected. Carfentanil was only detected by kits specifically designed for its recognition. In general, analogs with group additions to the piperidine, or bulky rings or long alkyl chain modifications in the N-aryl or alkyl amide regions, were poorly detected compared to other types of modifications. This preliminary information is useful for screening diagnostic, forensic and unknown powder samples for the presence of fentanyl analogs and guiding future testing improvements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drug and Opioid-Involved Overdose Deaths — United States, 2017–2018
Wilson, N., Kariisa, M., Seth, P., Smith, H., & Davis, N. L. (2020) · MMWR. Morbidity and Mortality Weekly Report · doi:10.15585/mmwr.mm6911a4 · Cited by 1,123 · cited 1×
“Nearly 450,000 people died from drug overdoses involving both prescription and illicit opioids between 1999 and 2018 (4).”
BackgroundKaramouzian, M., Dohoo, C., Forsting, S., McNeil, R., Kerr, T., & Lysyshyn, M. (2018) · Harm Reduction Journal · doi:10.1186/s12954-018-0252-8 · Cited by 209
Cited by
Testing the test strips: laboratory performance of fentanyl test strips
Halifax, J. C., Lim, L., Ciccarone, D., & Lynch, K. L. (2024) · Harm Reduction Journal · doi:10.1186/s12954-023-00921-8 · Cited by 45
“As summarized in Table 1, these studies demonstrate a variance in the effective cutoff concentration for true positive detection of fentanyl, with only one assessment approaching the manufacturer reported limit of detection of 20 ng/mL [41–46].”
BackgroundResultPark, J. N., Sherman, S. G., Sigmund, V., Breaud, A., Martin, K., & Clarke, W. A. (2022) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2022.109610 · Cited by 43
Fentanyl Test Strips for Harm Reduction: A Scoping Review
Kutscher, E., Barber Grossi, M., LaPolla, F., & Lee, J. D. (2024) · Journal of Addiction Medicine · doi:10.1097/adm.0000000000001321 · Cited by 30
Norman, C., Marland, V., McKenzie, C., Ménard, H., & Nic Daéid, N. (2023) · International Journal of Drug Policy · doi:10.1016/j.drugpo.2023.104102 · Cited by 25
Metadata
- Authors
- Wharton, R. E., Casbohm, J., Hoffmaster, R., Brewer, B. N., Finn, M. G., & Johnson, R. C.
- Venue
- Journal of Analytical Toxicology
- Publisher
- Oxford University Press (OUP)
- Published
- 2021-01-04
- Volume
- 45
- Issue
- 2
- Pages
- 111-116
- ISSN
- 0146-4760 (ISSN-L)
- 1945-2403
- OpenAlex
- W3120718124
- Cited by
- 38
- References
- 2
- FWCI
- 10.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.