CoChat

False-Positive Amphetamines in Urine Drug Screens: A 6-Year Review

Pope, Jeffrey D, Drummer, Olaf H, Schneider, Hans G · 2023 · Journal of Analytical Toxicology

The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index.

Abstract

Immunoassays are routinely used to provide rapid urine drug screening results in the clinical setting. These screening tests are prone to false-positive results and ideally require confirmation by mass spectrometry. In this study, we have examined a large number of urine specimens where drugs other than amphetamines may have caused a false-positive amphetamine immunoassay screening result. Urine drug screens (12,250) in a clinical laboratory that used the CEDIA amphetamine/ecstasy method were reviewed for false-positive results over a 6-year period (2015–2020). An additional 3,486 referred samples, for which confirmatory--mass spectrometry was requested, were also reviewed. About 86 in-house samples and 175 referral samples that were CEDIA false-positive screens were further analyzed by an LC–QTOF general unknown screen. Potential cross-reacting drugs were identified, and their molecular similarities to the CEDIA targets were determined. Commercial standards were also analyzed for cross-reactivity in the amphetamine/ecstasy CEDIA screen. Positive amphetamine results in 3.9% of in-house samples and 9.9% of referred tests for confirmatory analysis were false positive for amphetamines. Of these false-positive specimens, on average, 6.8 drugs were detected by the LC–QTOF screen. Several drugs were identified as possible cross-reacting drugs to the CEDIA amphetamine/ecstasy assay. Maximum common substructure scores for 70 potential cross-reacting compounds were calculated. This was not helpful in identifying cross-reacting drugs. False-positive amphetamine screens make up to 3.9–9.9% of positive amphetamine screens in the clinical laboratory. Knowledge of cross-reacting drugs may be helpful when mass spectrometry testing is unavailable.

Overview

Integrity signals

Registry

Crossref · 10.1093/jat/bkac089

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 37 references

Research works printed but not linked: 1

  1. Varon, 2015, Determination of verapamil through LC-ESI-MS-MS in a case of fatal intoxication, Rev Case Reports, 1, 23

Cited by

Metadata

Authors
Pope, J. D., Drummer, O. H., & Schneider, H. G.
Affiliations
  • The Alfred Hospital (AU)
  • Victorian Institute of Forensic Medicine (AU)
Corresponding author
Pope, Jeffrey D
Venue
Journal of Analytical Toxicology
Published
2022-11-11
Volume
47
Issue
3
Pages
263-270
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W4308771126
Cited by
25
References
38
Citations by year
2026: 9 · 2025: 8 · 2024: 6 · 2023: 2
FWCI
2.73
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Analytical Toxicology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Agricultural and Biological Sciences › Animal Science and Zoology › Pharmacological Effects and Assays
Keywords
false positives, urine drug testing, cross-reactivity, immunoassay interference, confirmatory testing, maximum common substructure, drug screening
MeSH terms
Amphetamine, Amphetamines, Immunoassay, Mass Spectrometry, Substance Abuse Detection, N-Methyl-3,4-methylenedioxyamphetamine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.